510(k) Report

510(k) · Cleared

Cleared

Neurodyn Portable Tens Nfes, Neurodyn Portable Tens

K131923510(k) TraditionalCleared Jul 3, 2014372-day reviewClass II21 CFR 882.5810

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Techlink International · GZI Stimulator, Neuromuscular, External Functional

Cleared on Jul 3, 2014 as substantially equivalent to K121369 (Ibramed Equipamentos Medicos, 2012) and 1 other predicate after a 372-day review. Its family tree reaches back 2 generations to 1993.

Decided
Jul 3, 2014
Review
372 days
Class
Class II
Product code
GZI
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K931781 (1993). 6 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2012: 1 other ancestor2003: 1 other ancestor2000: 1 other ancestor1996: 1 other ancestorK931781 · Jace Tri-Stim Device · Jace Systems, Inc. · 1993K021100 · 300 PV Complete Electrotherapy System · Empi · 2002199019952000200520102015
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors K021100 · 300 PV Complete Electrotherapy System · Empi · 2002K931781 · Jace Tri-Stim Device · Jace Systems, Inc. · 19930
  1. Root · 2 generations backK931781 Jace Tri-Stim DeviceJace Systems, Inc. · 1993
  2. 1 generation backK021100 300 PV Complete Electrotherapy SystemEmpi · 2002
  3. This deviceK131923 Neurodyn Portable Tens Nfes, Neurodyn Portable TensTechlink International · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K931781Jace Tri-Stim DeviceJace Systems, Inc.1993—
−1K021100300 PV Complete Electrotherapy SystemEmpi2002—
0 (this device)K131923Neurodyn Portable Tens Nfes, Neurodyn Portable TensTechlink International2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200010
200310
201210
FIG. 1 — Lineage of K131923, 1993–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GZI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZI device

  1. #1 K243828 Cionic Neural Sleeve (NS-200)score 12.9 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K121369Neurodyn Ruby Muscle Stimulator, Neurodyn Aussie Muscle Stimulator
Summary page 1
…GZJ; GZI Classification Panel: Neurology Regulation Numbers: 21 CFR 882.5890 and 21 CFR 882.5810 Substantial Equivalence: K121369 Neurodyn/Aussie Powered Muscle Stimnulator by Ibramed; K021100 300 PV…
Ibramed Equipamentos Medicos2012—
*K021100300 PV Complete Electrotherapy System
Summary page 1
…21 CFR 882.5890 and 21 CFR 882.5810 Substantial Equivalence: K121369 Neurodyn/Aussie Powered Muscle Stimnulator by Ibramed; K021100 300 PV Complete Electrotherapy System by EMPI Indications for Use Indications for FES device: -…
Empi2002—

Also cleared against K121369: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 12.0 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K121369.

How does its category compare?

All GZI devices

GZI Stimulator, Neuromuscular, External Functional: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · GZI

2in 2025

2007: 42008: 12009: 12011: 62012: 22013: 22014: 32015: 12016: 12017: 62018: 22019: 22020: 22021: 12022: 42023: 12024: 22025: 2
2007high 6 (2011) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZI

110in 2022

2007: 81 days median2011: 139 days median2014: 299 days median2017: 168 days median2022: 110 days median
2007high 299 (2014) · low 81 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZI

1in 2008

2008: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GZI

3in 2025

2007: 12008: 22009: 82010: 12011: 32012: 22014: 22015: 32017: 22018: 12019: 42021: 12022: 32023: 12024: 12025: 3
2007high 8 (2009) · low 0 (2013)2025

MAUDE reports naming product code GZI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200748101
20081—12
20091—08
20100—01
2011613903
20122—02
20132—00
2014329902
20151—03
20161—00
2017616802
20182—01
20192—04
20202—00
20211—01
2022411003
20231—01
20242—01
20252—03
20260—0—

What is it indicated for?

indications for FES device:

- Stimulation of the muscles in the leg and ankle of partially paralyzed patients to provide flexion of the foot and thus improve the patients gait.

Indications for TENS device:

- Symptomatic relief of chronic (long term) intractable pain

- Symptomatic relief of past-traumatic acute pain and post surgical pain

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131923: Neurodyn Portable Tens Nfes, Neurodyn Portable Tens.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131923

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026