510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Lemaitre 8F Occlusion Catheter

K132022510(k) TraditionalCleared Nov 6, 2013128-day reviewClass II21 CFR 870.4450Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

LeMaitre Vascular, Inc. · MJN Catheter, Intravascular Occluding, Temporary

Cleared on Nov 6, 2013 as substantially equivalent to K093911 (Edwards Lifesciences, LLC, 2010) after a 128-day review. Its family tree reaches back 1 generation to 2010. It has been recalled once.

Decided
Nov 6, 2013
Review
128 days
Class
Class II
Product code
MJN
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K093911 (2010). No later device cites it as a predicate yet.

K093911 · Fogarty Occlusion Catheter · Edwards Lifesciences, LLC · 2010201020122014
  1. Root · 1 generation backK093911 Fogarty Occlusion CatheterEdwards Lifesciences, LLC · 2010
  2. This deviceK132022 Lemaitre 8F Occlusion CatheterLeMaitre Vascular, Inc. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K093911Fogarty Occlusion CatheterEdwards Lifesciences, LLC2010—
0 (this device)K132022Lemaitre 8F Occlusion CatheterLeMaitre Vascular, Inc.2013—
FIG. 1 — Lineage of K132022, 2010–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MJN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MJN device

  1. #1 K243795 pREBOA-PRO Catheterscore 12.1 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K093911Fogarty Occlusion CatheterEdwards Lifesciences, LLC2010—

Also cleared against K093911: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 24, 2019Class IIZ-2448-2019Labeling mix-upsincorrect device size being listed on the impacted device packaging

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K093911.

How does its category compare?

All MJN devices

MJN Catheter, Intravascular Occluding, Temporary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · MJN

2in 2025

2007: 22008: 32009: 52010: 52011: 42012: 22013: 42014: 22015: 42016: 32017: 32018: 32019: 32020: 42021: 42022: 22023: 12025: 2
2007high 5 (2009) · low 0 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MJN

116in 2021

2008: 153 days median2009: 39 days median2010: 30 days median2011: 69 days median2013: 87 days median2015: 245 days median2016: 110 days median2017: 54 days median2018: 63 days median2019: 117 days median2020: 64 days median2021: 116 days median
2007high 245 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MJN

1in 2020

2008: 22010: 12011: 12013: 82015: 12016: 22018: 12020: 1
2007high 8 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MJN

194in 2025

2007: 252008: 262009: 252010: 352011: 922012: 532013: 762014: 1002015: 902016: 712017: 1572018: 1072019: 1392020: 1572021: 1582022: 1482023: 1812024: 2242025: 194
2007high 224 (2024) · low 25 (2007)2025

MAUDE reports naming product code MJN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—025
20083153226
2009539025
2010530135
2011469192
20122—053
2013487876
20142—0100
20154245190
20163110271
20173540157
20183631107
201931170139
20204641157
202141160158
20222—0148
20231—0181
20240—0224
20252—0194
20260—0—

What is it indicated for?

LeMaitre SF Occlusion Catheter is indicated for temporary vessel occlusion.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K132022: Lemaitre 8F Occlusion Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K132022

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026