510(k) · Cleared
ClearedASCOT
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Backroads Consulting, Inc. · KWQ Appliance, Fixation, Spinal Intervertebral Body
Cleared on Dec 23, 2013 as substantially equivalent to K043082 (Signus Medizintechnik GmbH, 2004) and 4 other predicates after a 151-day review. Its family tree reaches back 9 generations to 1992.
- Decided
- Dec 23, 2013
- Review
- 151 days
- Class
- Class II
- Product code
- KWQ
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 9 generations to K922087 (1992). 36 ancestors in all, the oldest K914362 (1992). No later device cites it as a predicate yet.
- Root · 9 generations backK922087 Anterior Cervical Plate SystemSofamor Danek Mfg., Inc. · 1992
- 5 generations between
- 3 generations backK043181 Modification to Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2004
- 2 generations backK051815 Modification to Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2005
- 1 generation backK062110 Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2006
- This deviceK132310 ASCOTBackroads Consulting, Inc. · 2013
Show all 9 generations
- Root · 9 generations backK922087 Anterior Cervical Plate SystemSofamor Danek Mfg., Inc. · 1992
- 8 generations backK990005 Spinal Concepts, Inc. (Sci) Anterior Cervical Plate SystemSpinal Concepts, Inc. · 1999 · Recalled
- 7 generations backK000486 Abc Cervical Plating SystemAesculap, Inc. · 2000
- 6 generations backK012184 Blackstone Iii Anterior Cervical Plating SystemBlackstone Medical, Inc. · 2002
- 5 generations backK030595 Blackstone Fusion Anterior Cervical Plating SystemBlackstone Medical, Inc. · 2003
- 4 generations backK040003 Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2004
- 3 generations backK043181 Modification to Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2004
- 2 generations backK051815 Modification to Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2005
- 1 generation backK062110 Vertebron SCP Cervical Plate SystemVertebron, Inc. · 2006
- This deviceK132310 ASCOTBackroads Consulting, Inc. · 2013
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K922087 | Anterior Cervical Plate System | Sofamor Danek Mfg., Inc. | 1992 | — |
| −8 | K990005 | Spinal Concepts, Inc. (Sci) Anterior Cervical Plate System | Spinal Concepts, Inc. | 1999 | 1 |
| −7 | K000486 | Abc Cervical Plating System | Aesculap, Inc. | 2000 | — |
| −6 | K012184 | Blackstone Iii Anterior Cervical Plating System | Blackstone Medical, Inc. | 2002 | — |
| −5 | K030595 | Blackstone Fusion Anterior Cervical Plating System | Blackstone Medical, Inc. | 2003 | — |
| −4 | K040003 | Vertebron SCP Cervical Plate System | Vertebron, Inc. | 2004 | — |
| −3 | K043181 | Modification to Vertebron SCP Cervical Plate System | Vertebron, Inc. | 2004 | — |
| −2 | K051815 | Modification to Vertebron SCP Cervical Plate System | Vertebron, Inc. | 2005 | — |
| −1 | K062110 | Vertebron SCP Cervical Plate System | Vertebron, Inc. | 2006 | — |
| 0 (this device) | K132310 | ASCOT | Backroads Consulting, Inc. | 2013 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1993 | 2 | 0 |
| 1995 | 2 | 0 |
| 1997 | 4 | 0 |
| 1998 | 5 | 0 |
| 1999 | 3 | 0 |
| 2000 | 2 | 0 |
| 2001 | 3 | 0 |
| 2002 | 2 | 0 |
| 2004 | 2 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWQ device
- #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K043082 | The Tosca Anterior Cervical Plate SystemSummary page 1…The ASCOr' implant components are manufactured from titanium alloy (Ti-6A1-4V ELI) as described by ASTM F136. Predicate Devices: TOSCA® (K043082) TOSCA® 11(KO8O8iS) VERTEBRON SCP TM (K051815 & K0621 10) Uni… | 2004 |
| * | K080815 | Tosca II Anterior Cervical Plate System | 2008 |
| * | K051815 | Modification to Vertebron SCP Cervical Plate SystemSummary page 1…alloy (Ti-6A1-4V ELI) as described by ASTM F136. Predicate Devices: TOSCA® (K043082) TOSCA® 11(KO8O8iS) VERTEBRON SCP TM (K051815 & K0621 10) Uniplate m (K042544) Performance Data: Mechanical testing of the worst case ASCOr was per… | 2005 |
| * | K062110 | Vertebron SCP Cervical Plate SystemSummary page 1…6A1-4V ELI) as described by ASTM F136. Predicate Devices: TOSCA® (K043082) TOSCA® 11(KO8O8iS) VERTEBRON SCP TM (K051815 & K0621 10) Uniplate m (K042544) Performance Data: Mechanical testing of the worst case ASCOr was performed… | 2006 |
| * | K042544 | Uniplate Anterior Cervical Plate SystemSummary page 1…ate Devices: TOSCA® (K043082) TOSCA® 11(KO8O8iS) VERTEBRON SCP TM (K051815 & K0621 10) Uniplate m (K042544) Performance Data: Mechanical testing of the worst case ASCOr was performed according to ASTM F1 717… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 1.2 years on median.
- 4 of the 36 ancestors have a recall of any class.
- 1 other device also cites its predicate K043082.
How does its category compare?
All KWQ devicesKWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · KWQ
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWQ
64in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWQ
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWQ
248in 2025
MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 101 | 2 | 288 |
| 2008 | 32 | 70 | 33 | 348 |
| 2009 | 23 | 90 | 35 | 355 |
| 2010 | 23 | 104 | 2 | 691 |
| 2011 | 22 | 95 | 5 | 415 |
| 2012 | 26 | 90 | 7 | 544 |
| 2013 | 22 | 88 | 6 | 796 |
| 2014 | 17 | 124 | 0 | 546 |
| 2015 | 25 | 102 | 2 | 562 |
| 2016 | 15 | 121 | 9 | 502 |
| 2017 | 20 | 67 | 8 | 492 |
| 2018 | 22 | 95 | 1 | 341 |
| 2019 | 26 | 81 | 0 | 298 |
| 2020 | 26 | 55 | 0 | 400 |
| 2021 | 17 | 59 | 0 | 591 |
| 2022 | 18 | 85 | 0 | 392 |
| 2023 | 16 | 59 | 0 | 320 |
| 2024 | 17 | 64 | 0 | 419 |
| 2025 | 7 | 64 | 0 | 248 |
| 2026 | 10 | 76 | 0 | — |
What is it indicated for?
AsCorO is Intended for anterior cervical fixation (C2-C7) for the following Indications: degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spondylolistiiesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures 0.e., scollosis, kyphosis and/or lordosis). tumor, pseudarthrosis and failed previous fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K132310 · printed Nov 6, 2026
Cite this page
510(k) Report. “K132310: ASCOT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K132310
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026