510(k) Report

510(k) · Cleared

Cleared

Fuse 1C Colonoscopy System

K132839510(k) TraditionalCleared Feb 6, 2014149-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Endochoice, Inc. · FDF Colonoscope And Accessories, Flexible/Rigid

Cleared on Feb 6, 2014 as substantially equivalent to K130718 (Peermedical, Ltd., 2013) after a 149-day review. Its family tree reaches back 8 generations to 1992. 2 later devices descend from it.

Decided
Feb 6, 2014
Review
149 days
Class
Class II
Product code
FDF
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K921244 (1992). 24 ancestors in all, the oldest K822846 (1982). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor2000: 1 other ancestor1999: 1 other ancestor1996: 5 other ancestors1995: 1 other ancestor1994: 3 other ancestors1993: 2 other ancestors1982: 1 other ancestor1992: 1 other ancestor2014: 1 descendant cleared2016: 1 descendant clearedK921244 · Disposable Protective Sheath · Vision-Sciences, Inc. · 1992×2: 2 generations cleared close together, K961591 (1996), K963795 (1996) K021344 · B-F200 Bronchoscope with BSS-F21 Endosheath System · Vision-Sciences, Inc. · 2002K032688 · Colonosight Model 510B · Sightline Technologies, Ltd. · 2004K081004 · Protectiscope CS Colonoscope, Non-Intrapull · Stryker GI · 2008K120289 · Peerscope System · Peermedical · 2012K130718 · Peerscope System · Peermedical, Ltd. · 201319801990200020102020
  1. Root · 8 generations backK921244 Disposable Protective SheathVision-Sciences, Inc. · 1992
  2. 7 generations backK961591 Disposable Endosheath for E-F100 Flexible NasopharyngoscopeVision-Sciences, Inc. · 1996
  3. 6 generations backK963795 Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21…Vision-Sciences, Inc. · 1996
  4. 5 generations backK021344 B-F200 Bronchoscope with BSS-F21 Endosheath SystemVision-Sciences, Inc. · 2002
  5. 4 generations backK032688 Colonosight Model 510BSightline Technologies, Ltd. · 2004
  6. 3 generations backK081004 Protectiscope CS Colonoscope, Non-IntrapullStryker GI · 2008
  7. 2 generations backK120289 Peerscope SystemPeermedical · 2012
  8. 1 generation backK130718 Peerscope SystemPeermedical, Ltd. · 2013
  9. This deviceK132839 Fuse 1C Colonoscopy SystemEndochoice, Inc. · 2014
  10. Descendant · cites it directly · 1 of its ownK141598 Fuse Colonoscopy SystemEndochoice, Inc. · 2014 · Recalled
  11. Descendant · 2 generations on · 0 of its ownK160275 Fuse Endoscopic System with FuseBox ProcessorEndochoice, Inc. · 2016

Most influential descendants

Showing 2 of 2 · See all
  • K141598Fuse Colonoscopy SystemEndochoice, Inc. · 2014 · cites it directly1descendant
  • K160275Fuse Endoscopic System with FuseBox ProcessorEndochoice, Inc. · 2016 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K921244Disposable Protective SheathVision-Sciences, Inc.1992—
−7K961591Disposable Endosheath for E-F100 Flexible NasopharyngoscopeVision-Sciences, Inc.1996—
−6K963795Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21 Disposable…Vision-Sciences, Inc.1996—
−5K021344B-F200 Bronchoscope with BSS-F21 Endosheath SystemVision-Sciences, Inc.2002—
−4K032688Colonosight Model 510BSightline Technologies, Ltd.2004—
−3K081004Protectiscope CS Colonoscope, Non-IntrapullStryker GI2008—
−2K120289Peerscope SystemPeermedical2012—
−1K130718Peerscope SystemPeermedical, Ltd.2013—
0 (this device)K132839Fuse 1C Colonoscopy SystemEndochoice, Inc.2014—
+1K141598Fuse Colonoscopy SystemEndochoice, Inc.20141
+2K160275Fuse Endoscopic System with FuseBox ProcessorEndochoice, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
199210
199320
199430
199510
199650
199910
200010
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201610
FIG. 1 — Lineage of K132839, 1992–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FDF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FDF device

  1. #1 K230332 Ambu® aScope™ Colon; Ambu® aBox™ 2score 20.1 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130718Peerscope System
Summary page 2
…he lower digestive tract. The system enables physicians to view high resolution wide field of view of up to 3000. The Fuse I C is a modification of the legally marketed (K1 30718) PeerScope system Model I-I (the predicate device). The device has been modified to include a water bottle, cap, and tubing that…
Peermedical, Ltd.2013—

Also cleared against K130718: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141598Fuse Colonoscopy SystemEndochoice, Inc.20141

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 6 companies; a new generation was cleared every 3.7 years on median.
  • 3 of the 24 ancestors have a recall of any class.
  • Of its descendants, K141598 (Endochoice, Inc., 2014) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K130718.

How does its category compare?

All FDF devices

FDF Colonoscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · FDF

4in 2025

2007: 42008: 22009: 62010: 42011: 22012: 72013: 22014: 62015: 22016: 72017: 42018: 72019: 42020: 42021: 32022: 52023: 62024: 22025: 42026 (partial year): 5
2007high 7 (2012) · low 2 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FDF

194in 2025

2007: 70 days median2009: 91 days median2010: 101 days median2012: 241 days median2014: 164 days median2016: 98 days median2017: 36 days median2018: 101 days median2019: 56 days median2020: 250 days median2021: 30 days median2022: 147 days median2023: 203 days median2025: 194 days median2026 (partial year): 147 days median
2007high 250 (2020) · low 30 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FDF

8in 2023

2015: 12016: 12020: 12023: 8
2007high 8 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FDF

17,231in 2025

2007: 812008: 682009: 832010: 482011: 772012: 882013: 632014: 602015: 1002016: 1702017: 3702018: 3882019: 4172020: 6872021: 2,4442022: 8,3452023: 11,7482024: 12,1282025: 17,231
2007high 17,231 (2025) · low 48 (2010)2025

MAUDE reports naming product code FDF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007470081
20082—068
2009691083
20104101048
20112—077
20127241088
20132—063
20146164060
20152—1100
20167981170
20174360370
201871010388
20194560417
202042501687
202133002,444
2022514708,345
20236203811,748
20242—012,128
20254194017,231
202651470—

What is it indicated for?

The Fuse IC Colonoscopy System is intended for diagnostic visualization of the digestive tract. The system also provides access for therapeutic interventions using standard endoscopy tools. The Fuse IC Colonoscopy System is indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon and ileocecal valve) for adult patients.

The Fuse IC Colonoscopy System consists of camera heads, endoscopes, video system, light source and other ancillary equipment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K132839: Fuse 1C Colonoscopy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K132839

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026