Endochoice, Inc. · FDF Colonoscope And Accessories, Flexible/Rigid
Cleared on Feb 6, 2014 as substantially equivalent to K130718 (Peermedical, Ltd., 2013) after a 149-day review. Its family tree reaches back 8 generations to 1992. 2 later devices descend from it.
- Decided
- Feb 6, 2014
- Review
- 149 days
- Class
- Class II
- Product code
- FDF
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 8 generations to K921244 (1992). 24 ancestors in all, the oldest K822846 (1982). 2 later devices descend from it, 1 citing it directly.
- Root · 8 generations backK921244 Disposable Protective SheathVision-Sciences, Inc. · 1992
- 7 generations backK961591 Disposable Endosheath for E-F100 Flexible NasopharyngoscopeVision-Sciences, Inc. · 1996
- 6 generations backK963795 Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21…Vision-Sciences, Inc. · 1996
- 5 generations backK021344 B-F200 Bronchoscope with BSS-F21 Endosheath SystemVision-Sciences, Inc. · 2002
- 4 generations backK032688 Colonosight Model 510BSightline Technologies, Ltd. · 2004
- 3 generations backK081004 Protectiscope CS Colonoscope, Non-IntrapullStryker GI · 2008
- 2 generations backK120289 Peerscope SystemPeermedical · 2012
- 1 generation backK130718 Peerscope SystemPeermedical, Ltd. · 2013
- This deviceK132839 Fuse 1C Colonoscopy SystemEndochoice, Inc. · 2014
- Descendant · cites it directly · 1 of its ownK141598 Fuse Colonoscopy SystemEndochoice, Inc. · 2014 · Recalled
- Descendant · 2 generations on · 0 of its ownK160275 Fuse Endoscopic System with FuseBox ProcessorEndochoice, Inc. · 2016
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K921244 | Disposable Protective Sheath | Vision-Sciences, Inc. | 1992 | — |
| −7 | K961591 | Disposable Endosheath for E-F100 Flexible Nasopharyngoscope | Vision-Sciences, Inc. | 1996 | — |
| −6 | K963795 | Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21 Disposable… | Vision-Sciences, Inc. | 1996 | — |
| −5 | K021344 | B-F200 Bronchoscope with BSS-F21 Endosheath System | Vision-Sciences, Inc. | 2002 | — |
| −4 | K032688 | Colonosight Model 510B | Sightline Technologies, Ltd. | 2004 | — |
| −3 | K081004 | Protectiscope CS Colonoscope, Non-Intrapull | Stryker GI | 2008 | — |
| −2 | K120289 | Peerscope System | Peermedical | 2012 | — |
| −1 | K130718 | Peerscope System | Peermedical, Ltd. | 2013 | — |
| 0 (this device) | K132839 | Fuse 1C Colonoscopy System | Endochoice, Inc. | 2014 | — |
| +1 | K141598 | Fuse Colonoscopy System | Endochoice, Inc. | 2014 | 1 |
| +2 | K160275 | Fuse Endoscopic System with FuseBox Processor | Endochoice, Inc. | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1982 | 1 | 0 |
| 1992 | 1 | 0 |
| 1993 | 2 | 0 |
| 1994 | 3 | 0 |
| 1995 | 1 | 0 |
| 1996 | 5 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
| 2002 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2016 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FDF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FDF device
- #1 K230332 Ambu® aScope™ Colon; Ambu® aBox™ 2score 20.1 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K130718 | Peerscope SystemSummary page 2…he lower digestive tract. The system enables physicians to view high resolution wide field of view of up to 3000. The Fuse I C is a modification of the legally marketed (K1 30718) PeerScope system Model I-I (the predicate device). The device has been modified to include a water bottle, cap, and tubing that… | 2013 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K141598 | Fuse Colonoscopy System | 2014 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 6 companies; a new generation was cleared every 3.7 years on median.
- 3 of the 24 ancestors have a recall of any class.
- Of its descendants, K141598 (Endochoice, Inc., 2014) has gone furthest, with 1 descendant of its own.
- 1 other device also cites its predicate K130718.
How does its category compare?
All FDF devicesFDF Colonoscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · FDF
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FDF
194in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FDF
8in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FDF
17,231in 2025
MAUDE reports naming product code FDF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 70 | 0 | 81 |
| 2008 | 2 | — | 0 | 68 |
| 2009 | 6 | 91 | 0 | 83 |
| 2010 | 4 | 101 | 0 | 48 |
| 2011 | 2 | — | 0 | 77 |
| 2012 | 7 | 241 | 0 | 88 |
| 2013 | 2 | — | 0 | 63 |
| 2014 | 6 | 164 | 0 | 60 |
| 2015 | 2 | — | 1 | 100 |
| 2016 | 7 | 98 | 1 | 170 |
| 2017 | 4 | 36 | 0 | 370 |
| 2018 | 7 | 101 | 0 | 388 |
| 2019 | 4 | 56 | 0 | 417 |
| 2020 | 4 | 250 | 1 | 687 |
| 2021 | 3 | 30 | 0 | 2,444 |
| 2022 | 5 | 147 | 0 | 8,345 |
| 2023 | 6 | 203 | 8 | 11,748 |
| 2024 | 2 | — | 0 | 12,128 |
| 2025 | 4 | 194 | 0 | 17,231 |
| 2026 | 5 | 147 | 0 | — |
What is it indicated for?
The Fuse IC Colonoscopy System is intended for diagnostic visualization of the digestive tract. The system also provides access for therapeutic interventions using standard endoscopy tools. The Fuse IC Colonoscopy System is indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon and ileocecal valve) for adult patients.
The Fuse IC Colonoscopy System consists of camera heads, endoscopes, video system, light source and other ancillary equipment.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K132839 · printed Nov 5, 2026
Cite this page
510(k) Report. “K132839: Fuse 1C Colonoscopy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K132839
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026