510(k) · Cleared
ClearedMedcomp Power Injectable Safety Huber Needle
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Components, Inc. · FPA Set, Administration, Intravascular
Cleared on Jan 8, 2014 as substantially equivalent to K080544 (Medcomp, 2008) after a 117-day review. Its family tree reaches back 9 generations to 2000. 2 later devices descend from it.
- Decided
- Jan 8, 2014
- Review
- 117 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K001901 (2000). 24 ancestors in all, the oldest K863606 (1986). 2 later devices descend from it, 1 citing it directly.
- Root · 9 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 5 generations between
- 3 generations backK060812 Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex…C.R. Bard, Inc. · 2006 · Recalled
- 2 generations backK071846 Modification to EZ Huber Safety Infusion SetPfm Medical, Inc. · 2007
- 1 generation backK080544 UnassignedMedcomp · 2008
- This deviceK132880 Medcomp Power Injectable Safety Huber NeedleMedical Components, Inc. · 2014
- Descendant · cites it directly · 1 of its ownK162271 Pro-Lock CT Safety Infusion SetMedcomp (Medical Components, Inc.) · 2017
- Descendant · 2 generations on · 0 of its ownK171333 20G x 5/8 Pro-Lock CT Safety Infusion SetMedcomp (Dba Medical Components, Inc.) · 2017
Show all 9 generations
- Root · 9 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 8 generations backK012902 Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly…C.R. Bard, Inc. · 2001
- 7 generations backK031129 Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc. · 2003
- 6 generations backK034019 Poly Per-Q-Cath Picc CathetersC.R. Bard, Inc. · 2004 · Recalled
- 5 generations backK050931 6 FR DL Powerpicc CatheterC.R. Bard, Inc. · 2005
- 4 generations backK051672 PowerpiccBard Access Systems, Inc. · 2005 · Recalled
- 3 generations backK060812 Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex…C.R. Bard, Inc. · 2006 · Recalled
- 2 generations backK071846 Modification to EZ Huber Safety Infusion SetPfm Medical, Inc. · 2007
- 1 generation backK080544 UnassignedMedcomp · 2008
- This deviceK132880 Medcomp Power Injectable Safety Huber NeedleMedical Components, Inc. · 2014
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K001901 | Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline… | C.R. Bard, Inc. | 2000 | 2 |
| −8 | K012902 | Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath… | C.R. Bard, Inc. | 2001 | — |
| −7 | K031129 | Poly Per-Q-Cath Picc Catheters; Poly Radpicc | C.R. Bard, Inc. | 2003 | — |
| −6 | K034019 | Poly Per-Q-Cath Picc Catheters | C.R. Bard, Inc. | 2004 | 1 |
| −5 | K050931 | 6 FR DL Powerpicc Catheter | C.R. Bard, Inc. | 2005 | — |
| −4 | K051672 | Powerpicc | Bard Access Systems, Inc. | 2005 | 1 |
| −3 | K060812 | Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-Multiple | C.R. Bard, Inc. | 2006 | 1 |
| −2 | K071846 | Modification to EZ Huber Safety Infusion Set | Pfm Medical, Inc. | 2007 | — |
| −1 | K080544 | Unassigned | Medcomp | 2008 | — |
| 0 (this device) | K132880 | Medcomp Power Injectable Safety Huber Needle | Medical Components, Inc. | 2014 | — |
| +1 | K162271 | Pro-Lock CT Safety Infusion Set | Medcomp (Medical Components, Inc.) | 2017 | — |
| +2 | K171333 | 20G x 5/8 Pro-Lock CT Safety Infusion Set | Medcomp (Dba Medical Components, Inc.) | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1989 | 4 | 0 |
| 1991 | 1 | 0 |
| 2000 | 2 | 0 |
| 2001 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K080544 | UnassignedSummary page 5…General Hospital C.F.R. Sections §880.5570 Product Code: PTI Class: II Predicate Devices: K080544, CT Injectable Safety Huber Needle, concurrence date August 14, 2008. Device Description:… | 2008 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K162271 | Pro-Lock CT Safety Infusion Set | 2017 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 5 companies; a new generation was cleared every 12 months on median.
- 11 of the 24 ancestors have a recall of any class.
- Of its descendants, K162271 (Medcomp (Medical Components, Inc.), 2017) has gone furthest, with 1 descendant of its own.
- 1 other device also cites its predicate K080544.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
The Medcomp® Power Injectable Huber Needle Safety Infusion Set is intended for use in the administration of fluids and drugs, as well as blood sampling through implanted vascular access ports. The Medcomp® Power Injectable Huber Needle Safety Infusion Set is also indicated for power injection of contrast media into the central venous system with implanted vascular access ports indicated for power injection. The maximum recommended infusion rate at 11.8 cPs is 5 ml/sec for 19 gauge and 20 gauge non-coring Huber style needles and 2 ml/sec for 22 gauge non-coring Huber style needles.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K132880 · printed Nov 4, 2026
Cite this page
510(k) Report. “K132880: Medcomp Power Injectable Safety Huber Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K132880
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026