510(k) Report

510(k) · Cleared

Recalled · Class II · 2017

Omnipore Customized Surgical Implants

K133046510(k) TraditionalCleared May 14, 2014229-day reviewClass II21 CFR 878.3500Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Matrix Surgical Holdings, LLC/Matrix Surgical USA · KKY Material, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Reconstruction

Cleared on May 14, 2014 as substantially equivalent to K123908 (Matrix Surgical USA, 2013) and 1 other predicate after a 229-day review. Its family tree reaches back 2 generations to 1992. It has been recalled once.

Decided
May 14, 2014
Review
229 days
Class
Class II
Product code
KKY
Recalls
1
Predicates
2

Its longest line of descent runs back 2 generations to K922489 (1992). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2013: 1 other ancestorK922489 · Medpor Surg Implant Material:Prefor Cran/Fac Impla · Porex Technologies Corp. · 1992 · recalledK083621 · Medpor Customized Surgical Implant · Porex Surgical, Inc. · 2009199019952000200520102015
  1. Root · 2 generations backK922489 Medpor Surg Implant Material:Prefor Cran/Fac ImplaPorex Technologies Corp. · 1992 · Recalled
  2. 1 generation backK083621 Medpor Customized Surgical ImplantPorex Surgical, Inc. · 2009
  3. This deviceK133046 Omnipore Customized Surgical ImplantsMatrix Surgical Holdings, LLC/Matrix Surgical USA · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K922489Medpor Surg Implant Material:Prefor Cran/Fac ImplaPorex Technologies Corp.19921
−1K083621Medpor Customized Surgical ImplantPorex Surgical, Inc.2009—
0 (this device)K133046Omnipore Customized Surgical ImplantsMatrix Surgical Holdings, LLC/Matrix Surgical USA2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K133046, 1992–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KKY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KKY device

  1. #1 K211514 Longeviti PorousFit implantscore 2.0 · 2 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K123908Omnipore Surgical Implants and Accessories
Summary page 4
…composite implant material Product Code: KKY Legally Marketed Predicate Device: Matrix Surgical USA - OmniPore® Surgical Implants - 510(k) # K123908 POREX Surgical Inc. (now owned by Stryker® Craniomaxillofacial) - MEDPOR® Customized Surgical Implant - 510(k) # K0…
Matrix Surgical USA20133
*K083621Medpor Customized Surgical Implant
Summary page 4
…Pore® Surgical Implants - 510(k) # K123908 POREX Surgical Inc. (now owned by Stryker® Craniomaxillofacial) - MEDPOR® Customized Surgical Implant - 510(k) # K083621 Device Description: The OmniPore® Customized Surgical Implants are marketed as single patient use sterile implants tha…
Porex Surgical, Inc.2009—

Also cleared against K123908: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 25, 2017Class IIZ-1382-2017OtherMislabeling. The packaging labeled as left mandible contained a right mandible.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 3 companies; a new generation was cleared every 16.4 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K123908.

How does its category compare?

All KKY devices

KKY Material, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Reconstruction: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · KKY

1in 2021

2007: 12008: 12010: 12011: 12013: 12014: 32015: 12016: 22021: 1
2007high 3 (2014) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KKY

224in 2014

2014: 224 days median
2007high 224 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KKY

1in 2013

2008: 42013: 1
2007high 4 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KKY

1in 2025

2008: 32009: 92010: 52011: 132012: 222013: 172014: 92015: 182016: 252017: 192018: 172019: 202020: 132021: 122022: 12023: 32024: 12025: 1
2007high 25 (2016) · low 0 (2007)2025

MAUDE reports naming product code KKY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—43
20090—09
20101—05
20111—013
20120—022
20131—117
2014322409
20151—018
20162—025
20170—019
20180—017
20190—020
20200—013
20211—012
20220—01
20230—03
20240—01
20250—01
20260—0—

What is it indicated for?

OmniPore® Customized Surgical Implants are intended for non-weight bearing applications of craniofacial reconstruction/ cosmetic surgery and repair of craniofacial trauma. OmniPore Customized Surgical Implants are also intended for the augmentation or restoration of contour in the craniomaxillofacial skeleton.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K133046: Omnipore Customized Surgical Implants.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K133046

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026