ClearedEGV1.1 Self Monitoring Blood Glucose System and EGV1.1 Pro Monitoring Blood Glucose System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Eps Bio Technology Corp. · LFR Glucose Dehydrogenase, Glucose
Cleared on Apr 28, 2014 after a 161-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Apr 28, 2014
- Review
- 161 days
- Class
- Class II
- Product code
- LFR
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LFR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LFR devicesLFR Glucose Dehydrogenase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · LFR
1in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · LFR
161in 2014
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LFR
1in 2012
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LFR
827in 2025
MAUDE reports naming product code LFR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 3 | 23,819 |
| 2008 | 0 | — | 1 | 6,584 |
| 2009 | 1 | — | 4 | 10,823 |
| 2010 | 0 | — | 0 | 4,865 |
| 2011 | 6 | 296 | 1 | 3,802 |
| 2012 | 13 | 152 | 1 | 3,341 |
| 2013 | 3 | 212 | 0 | 3,821 |
| 2014 | 3 | 161 | 0 | 3,960 |
| 2015 | 1 | — | 0 | 3,366 |
| 2016 | 0 | — | 0 | 2,145 |
| 2017 | 0 | — | 0 | 103 |
| 2018 | 0 | — | 0 | 108 |
| 2019 | 0 | — | 0 | 108 |
| 2020 | 0 | — | 0 | 132 |
| 2021 | 0 | — | 0 | 164 |
| 2022 | 0 | — | 0 | 101 |
| 2023 | 0 | — | 0 | 103 |
| 2024 | 0 | — | 0 | 171 |
| 2025 | 0 | — | 0 | 827 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The EGVI.I Pro Monitoring Blood Glucose System is intended for the quantitative measurement of glucose in venous whole blood or fresh capillary whole blood from fingertip. Testing is done outside the body (In Vitro diagnostic use). It is intended for multiple-patient use in professional healthcare settings as an aid to monitor the effectiveness of diabetes control. The system is only used with single-use lancing devices. The system is not to be used on…
Read the full statement (263 words)
The EGVI.I Pro Monitoring Blood Glucose System is intended for the quantitative measurement of glucose in venous whole blood or fresh capillary whole blood from fingertip. Testing is done outside the body (In Vitro diagnostic use). It is intended for multiple-patient use in professional healthcare settings as an aid to monitor the effectiveness of diabetes control. The system is only used with single-use lancing devices. The system is not to be used on neonates, nor for the diagnosis of, or screening for diabetes mellitus.
The system consists of the EGVI.l Pro meter and the EGV 1.1 Pro test strips. The EGVI.1 Pro meter only is used with the EGVI.I Pro test strips to quantitatively measure glucose in venous whole blood or fresh capillary whole blood from fingertip.
The EGV1.1 Self Monitoring Blood Glucose System is intended for the quantitative measurement of glucose in fresh capillary whole blood from fingertip, palm, or forearm. Testing is done outside the body (In Vitro diagnostic use). It is indicated for use at home (over the counter [QTC]) by a single patient with diabetes and should not be shared, as an aid to monitor the effectiveness of diabetes control. The system is not to be used on neonates, nor for the diagnosis of, or screening for diabetes mellitus. Alternative site testing can be only used during steady-state blood glucose conditions.
The system consists of the EGVI.lI meter and the EGV1.I1 test strips. The EGV1.I1 meter only is used with the EGVI. I test strips to quantitatively measure glucose in fresh capillary whole blood from fingertip, palm, or forearm.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K133537 · printed Nov 5, 2026
Cite this page
510(k) Report. “K133537: EGV1.1 Self Monitoring Blood Glucose System and EGV1.1 Pro Monitoring Blood Glucose System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K133537
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026