# K133589: Somatom Force

- Pathway: 510(k) (Traditional)
- Applicant: Siemens Medical Solutions USA, Inc.
- Decided: Apr 17, 2014 after 146 days
- Product code: JAK (System, X-Ray, Tomography, Computed)
- Device class: 2
- Regulation: 21 CFR 892.1750
- Recalls of this device: 9 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 7 generations back to K013561 (2001). 12 ancestors in all.
29 later devices descend from it; 3 cite it directly.
0 of 42 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K121072: Somatom Definition Flash, Siemens Medical Systems, Inc. (2012) Summary page 2.

## Most influential descendants
- K142955: SOMATOM Force, SOMATOM Definition Flash, SOMATOM Definition Edge, SOMATOM Definition AS/AS+, SOMATOM Definition AS Open, SOMATON Emotion 6/16, SOMATOM Sensation 64/Sensation Cardiac , SOMATOM Perspective SOMATOM Scope/ Scope Power (2015), 27 descendants of its own
- K161196: SOMATOM Drive (2016), 24 descendants of its own
- K162302: Somatom Confidence ® RT Pro (2016), 21 descendants of its own
- K173630: SOMATOM Force, SOMATOM Definition Flash, SOMATOM Drive, SOMATOM Definition Edge, SOMATOM Definition AS Open, SOMATOM Deinition AS/AS+, SOMATOM Confidence (2018), 20 descendants of its own
- K190578: SOMATOM Force, SOMATOM Definition Flash, SOMATOM Drive, SOMATOM Definition Edge, SOMATOM Definition AS Open, SOMATOM Edge Plus, SOMATOM Definition AS/AS+, SOMATOM Confidence (2019), 19 descendants of its own

## Recalls of this device
- Nov 24, 2020 · Class II · Z-0771-2021: System does not trigger a cancel command followed by a reload of the scan with the new parameter(s). This issue may result in a delay in diagnosis and/or need for patient rescan
- Jun 22, 2020 · Class II · Z-3025-2020: Sporadic problems with the current software may result in scanning workflow interruptions and unexpected user notifications causing delay in diagnosis or patient rescan
- Oct 7, 2019 · Class II · Z-0406-2020: Software issue identified in the software versions syngo CT VB20 running on the SOMATOM CT Scanner: scan aborts and system crashes
- Jul 3, 2019 · Class II · Z-2274-2019: Potential for four safety-related software issues impacting systems utilizing syngo.CT software version VB10A which may result in a scan abort.
- Oct 20, 2016 · Class II · Z-0692-2017: Siemens is providing software update version VA50A_SP3 to address the software bugs that were identified through normal field monitoring and the Global Complaint Handling Process. Correction for the p
- Apr 1, 2016 · Class II · Z-1558-2016: The Neonate Head protocol with the pediatric kernel Hp38 could result in artefacts and possibly lead to a misdiagnosis (i.e. either non-existing blood or liquid is mimicked in the images or actual exi
- Aug 18, 2015 · Class II · Z-0107-2016: Software and firmware bugs
- Feb 6, 2015 · Class II · Z-1267-2015: Possibility of image artifacts during data acquisition when using Adaptive Cardio Sequence, Turbo Flash, and Head modes. The update improves system start-up behavior and resuming, ECG handling with vi
- Dec 3, 2014 · Class II · Z-0971-2015: Artifacts are found in acquired imaging on the SOMATOM Force.

## Indications for use
This computed tomography system is intended to generate and process cross-sectional images of patients by computer reconstruction of x-ray transmission data. The images delivered by the system can be used by a trained physician as an aid in diagnosis.

Source page: https://510kreport.com/device/K133589