510(k) · Cleared
ClearedZL Microdent Natural Lock Implant System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Zl Microdent-Attachment GmbH & Co. KG · DZE Implant, Endosseous, Root-Form
Cleared on Aug 21, 2014 as substantially equivalent to K031345 (Nobel Biocare Uas, Inc., 2003) and 2 other predicates after a 261-day review. Its family tree reaches back 2 generations to 2003.
- Decided
- Aug 21, 2014
- Review
- 261 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 2 generations to K023952 (2003). 4 ancestors in all. No later device cites it as a predicate yet.
- Root · 2 generations backK023952 Replace One Piece Implant, HA, Replace One Piece Implant, TiuniteNobel Biocare Uas, Inc. · 2003
- 1 generation backK031345 Nobel Direct, Models 30937, 30938Nobel Biocare Uas, Inc. · 2003
- This deviceK133706 ZL Microdent Natural Lock Implant SystemZl Microdent-Attachment GmbH & Co. KG · 2014
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K023952 | Replace One Piece Implant, HA, Replace One Piece Implant, Tiunite | Nobel Biocare Uas, Inc. | 2003 | — |
| −1 | K031345 | Nobel Direct, Models 30937, 30938 | Nobel Biocare Uas, Inc. | 2003 | — |
| 0 (this device) | K133706 | ZL Microdent Natural Lock Implant System | Zl Microdent-Attachment GmbH & Co. KG | 2014 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K031345 | Nobel Direct, Models 30937, 30938Summary page 6…2 Classification name: Endosseous dental implant, Dental (21 CFR 872.3640- DZE) Predicate devices: K031345 Nobel Direct Nobel Biocare USA Inc., 22715 Savi Ranch Parkway, Yorba Linda, CA 92887, USA K062281 Zimmer One Piece,… | 2003 |
| * | K062281 | Zimmer One-Piece Implant, 4.7MM, Straight, Models ZOP47S10, ZOP47S11, ZOP47S13, ZOP47S16Summary page 6…tal implant, Dental (21 CFR 872.3640- DZE) Predicate devices: K031345 Nobel Direct Nobel Biocare USA Inc., 22715 Savi Ranch Parkway, Yorba Linda, CA 92887, USA K062281 Zimmer One Piece, 4,7mm K052997 Zimmer Once Piece Zimmer Dental Inc., 1900 Aston Ave., Carlsbad, CA 92008, USA… | 2006 |
| * | K052997 | Zimmer Dental One-Piece ImplantSummary page 6…DZE) Predicate devices: K031345 Nobel Direct Nobel Biocare USA Inc., 22715 Savi Ranch Parkway, Yorba Linda, CA 92887, USA K062281 Zimmer One Piece, 4,7mm K052997 Zimmer Once Piece Zimmer Dental Inc., 1900 Aston Ave., Carlsbad, CA 92008, USA… | 2006 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 11.1 years on median.
- 1 of the 4 ancestors has a recall of any class.
- 4 other devices also cite its predicate K031345.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
The NaturaLLock implant system is an endosseous dental implant system made of titanium. NaturaLLock implants are indicated for the support and retention of fixed single tooth and fixed partial denture restorations in the molar, premolar, cuspid, and incisor regions of partially edentulous jaws. NaturaLLock implants may be loaded immediately in the anterior mandibular arch if four are splinted together with a bar. NaturaLLock implants may be immediately restored with a temporary prosthesis that is not in functional occlusion.
The implants are offered in sterile condition, all other components can be sterilized in an autoclave .
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K133706 · printed Nov 6, 2026
Cite this page
510(k) Report. “K133706: ZL Microdent Natural Lock Implant System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K133706
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026