510(k) Report

510(k) · Cleared

Recalled · Class II · 2020

Arietta 70/Arietta S70/Arietta V70 Diagnostic Ultrasound Scanner

K134016510(k) TraditionalCleared Mar 28, 201488-day reviewClass II21 CFR 892.1550Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hitachi Aloka Medical,Ltd. (Hitachi Aloka Medical · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Mar 28, 2014 as substantially equivalent to K110673 (Hitachi Medical Systems America, Inc., 2011) and 1 other predicate after an 88-day review. Its family tree reaches back 13 generations to 1995. 25 later devices descend from it. It has been recalled 2 times.

Decided
Mar 28, 2014
Review
88 days
Class
Class II
Product code
IYN
Recalls
2
Predicates
2

Its longest line of descent runs back 13 generations to K935595 (1995). 79 ancestors in all, the oldest K891689 (1989). 25 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2011: 1 other ancestor2003: 7 other ancestors2008: 1 other ancestor2006: 2 other ancestors2004: 10 other ancestors2001: 6 other ancestors2000: 6 other ancestors1999: 6 other ancestors1997: 4 other ancestors2007: 1 other ancestor1996: 1 other ancestor2005: 5 other ancestors2002: 4 other ancestors1995: 4 other ancestors1998: 1 other ancestor1994: 4 other ancestors1992: 1 other ancestor1989: 1 other ancestor2023: 3 descendants cleared2016: 2 descendants cleared2017: 5 descendants cleared2018: 4 descendants cleared2019: 4 descendants cleared2020: 1 descendant cleared2021: 1 descendant cleared2025: 3 descendants cleared2022: 1 descendant cleared2026: 1 descendant clearedK935595 · Acuson Model 3001 · Acuson Corp. · 1995K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003×3: 3 generations cleared close together, K041319 (2004), K042770 (2004), K050240 (2005) K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalled×2: 2 generations cleared close together, K063138 (2006), K063803 (2007) K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K093466 · HI Vision Preirus Doagnostic Ultrasound Scanner Model HI Vision Preirus · Hitachi Medical Systems America, Inc. · 2010 · recalledK110673 · HI Vision Ascendus Diagnostic Ultrasound Scanner · Hitachi Medical Systems America, Inc. · 20111990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 8 other ancestors4 generations back: 4 other ancestors5 generations back: 8 other ancestors6 generations back: 6 other ancestors7 generations back: 8 other ancestors8 generations back: 9 other ancestors9 generations back: 9 other ancestors10 generations back: 10 other ancestors 1 generation forward: 6 descendants2 generations forward: 3 descendants3 generations forward: 6 descendants4 generations forward: 7 descendants5 generations forward: 3 descendants K110673 · HI Vision Ascendus Diagnostic Ultrasound Scanner · Hitachi Medical Systems America, Inc. · 2011K093466 · HI Vision Preirus Doagnostic Ultrasound Scanner Model HI Vision Preirus · Hitachi Medical Systems America, Inc. · 2010 · recalledK072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K063803 · Acuson Antares Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · recalledK063138 · Modification to Acuson Antares Ultrasound System · Siemens Medical Solutions USA, Inc. · 2006K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK050240 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK042770 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK041319 · Sequoia Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2004K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K935595 · Acuson Model 3001 · Acuson Corp. · 1995−10−50+5
  1. Root · 13 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 9 generations between
  3. 3 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
  4. 2 generations backK093466 HI Vision Preirus Doagnostic Ultrasound Scanner Model HI Vision…Hitachi Medical Systems America, Inc. · 2010 · Recalled
  5. 1 generation backK110673 HI Vision Ascendus Diagnostic Ultrasound ScannerHitachi Medical Systems America, Inc. · 2011
  6. This deviceK134016 Arietta 70/Arietta S70/Arietta V70 Diagnostic Ultrasound ScannerHitachi Aloka Medical,Ltd. (Hitachi Aloka Medical · 2014
  7. Descendant · cites it directly · 12 of its ownK153277 6200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A. · 2016
  8. Descendant · cites it directly · 9 of its ownK163082 6200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A. · 2017 · Recalled
  9. Descendant · 2 generations on · 8 of its ownK173291 6440 Ultrasound SystemEsaote, S.p.A. · 2018
  10. Descendant · cites it directly · 8 of its ownK171708 Aloka Arietta 850Hitachi Healthcare Americas Corporation · 2017 · Recalled
  11. Descendant · 2 generations on · 7 of its ownK173739 Aloka Arietta 850Hitachi Healthcare Americas Corporation · 2018 · Recalled
Show all 13 generations
  1. Root · 13 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 12 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
  3. 11 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
  4. 10 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
  5. 9 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
  6. 8 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  7. 7 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  8. 6 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  9. 5 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
  10. 4 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
  11. 3 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
  12. 2 generations backK093466 HI Vision Preirus Doagnostic Ultrasound Scanner Model HI Vision…Hitachi Medical Systems America, Inc. · 2010 · Recalled
  13. 1 generation backK110673 HI Vision Ascendus Diagnostic Ultrasound ScannerHitachi Medical Systems America, Inc. · 2011
  14. This deviceK134016 Arietta 70/Arietta S70/Arietta V70 Diagnostic Ultrasound ScannerHitachi Aloka Medical,Ltd. (Hitachi Aloka Medical · 2014

Showing 5 of 25 descendants. See all descendants

Descendants cleared per year

2016: 22017: 52018: 42019: 42020: 12021: 12022: 12023: 32025: 32026: 1
2016high 5 (2017) · low 0 (2024)2026

Most influential descendants

Showing 5 of 25 · See all
  • K1532776200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A. · 2016 · cites it directly12descendants
  • K1630826200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A. · 2017 · cites it directly9descendants
  • K1732916440 Ultrasound SystemEsaote, S.p.A. · 2018 · 2 generations on8descendants
  • K171708Aloka Arietta 850Hitachi Healthcare Americas Corporation · 2017 · cites it directly8descendants
  • K173739Aloka Arietta 850Hitachi Healthcare Americas Corporation · 2018 · 2 generations on7descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13K935595Acuson Model 3001Acuson Corp.1995—
−12K973767Harmonic Imaging with ContrastAcuson Corp.1997—
−11K022567Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp.2002—
−10K032114Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2003—
−9K041319Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2004—
−8K042770Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20041
−7K050240Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20051
−6K052894Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc.20051
−5K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc.2006—
−4K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI20079
−3K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc.2007—
−2K093466HI Vision Preirus Doagnostic Ultrasound Scanner Model HI Vision PreirusHitachi Medical Systems America, Inc.20101
−1K110673HI Vision Ascendus Diagnostic Ultrasound ScannerHitachi Medical Systems America, Inc.2011—
0 (this device)K134016Arietta 70/Arietta S70/Arietta V70 Diagnostic Ultrasound ScannerHitachi Aloka Medical,Ltd. (Hitachi Aloka Medical2014—
+1K1532776200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A.2016—
+1K1630826200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A.20172
+2K1732916440 Ultrasound SystemEsaote, S.p.A.2018—
+1K171708Aloka Arietta 850Hitachi Healthcare Americas Corporation20171
+2K173739Aloka Arietta 850Hitachi Healthcare Americas Corporation20182

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199210
199440
199540
199610
199740
199810
199960
200060
200160
200240
200370
2004100
200550
200620
200710
200810
201110
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201620
201750
201840
201940
202010
202110
202210
202330
202530
202610
FIG. 1 — Lineage of K134016, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110673HI Vision Ascendus Diagnostic Ultrasound Scanner
Summary page 2
…Arietta 70*! AscenduA S K 123828 Arietta S701/ K 110673 Function Arietta \V70* Color Flow…
Hitachi Medical Systems America, Inc.2011—
*K123828Prosound F75 Diagnostic Ultrasound System
Summary page 1
…rketed predicate Device(s): Hlitachi HIl VISION Ascendus Diagnostic Ultrasound Scanner [K! 1067311 Hlitachi Prosound F75 Diagnostic Ultrasound Scanner [K 123828] 4. Device Description: An ultrasound diagnostic system Nvith the folowying leatUres: " Ultrasound tra…
Hitachi Aloka Medical, Ltd.20131

Also cleared against K110673: 2 other devices →

What descends from it? (25)

See all 25

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K1532776200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A.201612
K1630826200 Ultrasound System and 6250 Ultrasound SystemEsaote, S.p.A.20179
K171708Aloka Arietta 850Hitachi Healthcare Americas Corporation20178
K232518EndoSound Vision System; EVSEndosound, Inc.20230
K163505Arietta PrecisionHitachi, Ltd.20170
K162583Aloka Lisendo 880Hitachi, Ltd.20160

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 31, 2020Class IIZ-1341-2020Process change controlThese 18 probes may have mis-wiring in the inner cables, causing decreased sensitivity and thus resulting in lower peak velocity readings.
May 2, 2017Class IIZ-2090-2017Device DesignThe strength of the arm mounting mechanism was insufficient and had to be redesigned.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 5 companies; a new generation was cleared every 11 months on median.
  • 18 of the 79 ancestors have a recall of any class.
  • Of its descendants, K153277 (Esaote, S.p.A., 2016) has gone furthest, with 12 descendants of its own.
  • 2 other devices also cite its predicate K110673.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The Hitachi Aloka Medical, Ltd. Arietta70/ AriettaS70 /AriettaV70 is intended for use by trained personnel (doctor, sonographer, etc.) for the diagnostic ultrasound evaluation of Abdominal, Cardiac, Intra-operative, Fetal, Pediatric, Small Organ, Peripheral vessel, Biopsy, Trans-rectal, Trans-vaginal, Musculoskeletal, Neonatal Cephalic, Adult Cephalic, Endoscopy, Intra-luminal, Gynecology, Urology and Laparoscopic clinical applications. The Modes of…

Read the full statement (92 words)

The Hitachi Aloka Medical, Ltd. Arietta70/ AriettaS70 /AriettaV70 is intended for use by trained personnel (doctor, sonographer, etc.) for the diagnostic ultrasound evaluation of Abdominal, Cardiac, Intra-operative, Fetal, Pediatric, Small Organ, Peripheral vessel, Biopsy, Trans-rectal, Trans-vaginal, Musculoskeletal, Neonatal Cephalic, Adult Cephalic, Endoscopy, Intra-luminal, Gynecology, Urology and Laparoscopic clinical applications.

The Modes of Operation are B mode, M mode, PW mode (Pulsed Wave Doppler), CW mode (Continuous Wave Doppler), Color Doppler, Amplitude Doppler (Color Flow Angiography), TDI (Tissue Doppler Imaging), 3D Imaging, 4D Imaging, Real Time Tissue Elastography, and Real Time Virtual Sonography.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K134016: Arietta 70/Arietta S70/Arietta V70 Diagnostic Ultrasound Scanner.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K134016

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026