510(k) Report

510(k) · Cleared

Recalled · Class II · 2016

1.5MM Hydro Expandable Lemaitre Valvulotome

K140042510(k) TraditionalCleared Apr 10, 201492-day reviewClass II21 CFR 870.4885Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

LeMaitre Vascular, Inc. · MGZ Valvulotome

Cleared on Apr 10, 2014 as substantially equivalent to K132190 (LeMaitre Vascular, Inc., 2013) and 1 other predicate after a 92-day review. Its family tree reaches back 3 generations to 1995. It has been recalled 3 times.

Decided
Apr 10, 2014
Review
92 days
Class
Class II
Product code
MGZ
Recalls
3
Predicates
2

Its longest line of descent runs back 3 generations to K946352 (1995). 6 ancestors in all, the oldest K890113 (1989). No later device cites it as a predicate yet.

Other ancestors, by year cleared 1998: 1 other ancestor1990: 1 other ancestor1989: 1 other ancestorK946352 · Lemaitre Valvulotome II · Vascutech, Inc. · 1995K080178 · Valvulotome by Koven · Koven Technology, Inc. · 2008K132190 · Expandable Lemaitre Valvulotome, Over-the-Wire Lemaitre Valvulotome · LeMaitre Vascular, Inc. · 20131985199019952000200520102015
  1. Root · 3 generations backK946352 Lemaitre Valvulotome IIVascutech, Inc. · 1995
  2. 2 generations backK080178 Valvulotome by KovenKoven Technology, Inc. · 2008
  3. 1 generation backK132190 Expandable Lemaitre Valvulotome, Over-the-Wire Lemaitre ValvulotomeLeMaitre Vascular, Inc. · 2013
  4. This deviceK140042 1.5MM Hydro Expandable Lemaitre ValvulotomeLeMaitre Vascular, Inc. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K946352Lemaitre Valvulotome IIVascutech, Inc.1995—
−2K080178Valvulotome by KovenKoven Technology, Inc.2008—
−1K132190Expandable Lemaitre Valvulotome, Over-the-Wire Lemaitre ValvulotomeLeMaitre Vascular, Inc.2013—
0 (this device)K1400421.5MM Hydro Expandable Lemaitre ValvulotomeLeMaitre Vascular, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199010
199810
FIG. 1 — Lineage of K140042, 1995–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MGZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MGZ device

  1. #1 K260188 LimFlow Vectorscore 11.9 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K132190Expandable Lemaitre Valvulotome, Over-the-Wire Lemaitre Valvulotome
Summary page 2
…Intended Use: It is used for the treatment of vascular disorders, and more particularly for excising or disrupting venous valves. Predicate Devices: 5 10(k): K 132190 (Change to indication) Device Name: Expandable LeMaitre Valvulotome, Over-the-Wire LeMaitre Valvulotome SE Date:…
LeMaitre Vascular, Inc.2013—
*K9807323M Cdi Quick-Cells with Heparin Treatment
Summary page 2
…8/5/20 13 Regulation Number: 21CFR §870.4885 Device Class Name: Valvulotome, External Vein Stripper Device Class: 11 Product Code: MGZ 5 10(k): K980732 Device Name: Expandable LeMaitre Valvulotome SE Date: 2/12/1999 Regulation Number: 2ICFR §870.4885 De…
3M Healthcare1998—

Also cleared against K132190: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 3, 2016Class IIZ-2544-2016Process controlWire which deploys the loop may be come detached at the handle causing the device to be inoperable
Aug 3, 2016Class IIZ-2543-2016Process controlWire which deploys the loop may be come detached at the handle causing the device to be inoperable
Aug 3, 2016Class IIZ-2545-2016Process controlWire which deploys the loop may be come detached at the handle causing the device to be inoperable

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 5.0 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K132190.

How does its category compare?

All MGZ devices

MGZ Valvulotome: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · MGZ

1in 2025

2008: 12011: 12013: 22014: 22019: 12022: 12025: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MGZ

Too few MGZ 510(k)s in any year since 2007 to give a median.

Recalls per year · MGZ

1in 2014

2014: 1
2007high 1 (2014) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MGZ

8in 2025

2007: 22009: 32014: 12016: 32017: 212018: 72019: 192020: 62021: 22022: 132023: 232024: 32025: 8
2007high 23 (2023) · low 0 (2008)2025

MAUDE reports naming product code MGZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20081—00
20090—03
20100—00
20111—00
20120—00
20132—00
20142—11
20150—00
20160—03
20170—021
20180—07
20191—019
20200—06
20210—02
20221—013
20230—023
20240—03
20251—08
20261—0—

What is it indicated for?

It is used for the treatment of vascular disorders, and more particularly for excising or disrupting venous valves.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140042: 1.5MM Hydro Expandable Lemaitre Valvulotome.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140042

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026