510(k) Report

510(k) · Cleared

Cleared

Imdx HSV-1/2 for Abbott M2000

K140198510(k) TraditionalCleared May 13, 2014106-day reviewClass II21 CFR 866.3305

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intelligent Medical Devices, Inc. · OQO Herpes Simplex Virus Nucleic Acid Amplification Assay

Cleared on May 13, 2014 as substantially equivalent to K100336 (Eragen Biosciences, 2010) after a 106-day review. Its family tree reaches back 2 generations to 1997. 2 later devices descend from it.

Decided
May 13, 2014
Review
106 days
Class
Class II
Product code
OQO
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K971662 (1997). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2018: 1 descendant cleared2015: 1 descendant clearedK971662 · Elvis HSV ID/Typing Test System · Diagnostic Hybrids, Inc. · 1997K100336 · Multicode - RTX Herpes Simplex Virus 1 and 2 Kit, Model 3711 · Eragen Biosciences · 20101995200020052010201520202025
  1. Root · 2 generations backK971662 Elvis HSV ID/Typing Test SystemDiagnostic Hybrids, Inc. · 1997
  2. 1 generation backK100336 Multicode - RTX Herpes Simplex Virus 1 and 2 Kit, Model 3711Eragen Biosciences · 2010
  3. This deviceK140198 Imdx HSV-1/2 for Abbott M2000Intelligent Medical Devices, Inc. · 2014
  4. Descendant · cites it directly · 0 of its ownK172509 Sentosa SA201 HSV 1/2 Qualitative PCR TestVela Diagnostics USA, Inc. · 2018
  5. Descendant · cites it directly · 0 of its ownK142156 Seegene Anyplex II HSV-1/2 AssaySeegene · 2015

Most influential descendants

Showing 2 of 2 · See all
  • K172509Sentosa SA201 HSV 1/2 Qualitative PCR TestVela Diagnostics USA, Inc. · 2018 · cites it directly0descendants
  • K142156Seegene Anyplex II HSV-1/2 AssaySeegene · 2015 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K971662Elvis HSV ID/Typing Test SystemDiagnostic Hybrids, Inc.1997—
−1K100336Multicode - RTX Herpes Simplex Virus 1 and 2 Kit, Model 3711Eragen Biosciences2010—
0 (this device)K140198Imdx HSV-1/2 for Abbott M2000Intelligent Medical Devices, Inc.2014—
+1K172509Sentosa SA201 HSV 1/2 Qualitative PCR TestVela Diagnostics USA, Inc.2018—
+1K142156Seegene Anyplex II HSV-1/2 AssaySeegene2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
201810
FIG. 1 — Lineage of K140198, 1997–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OQO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100336Multicode - RTX Herpes Simplex Virus 1 and 2 Kit, Model 3711
Summary page 2
…s. Substantial Equivalency The IM~x HSV-1/2 for Abbott mn2000 is substantially equivalent to the Eragen Bioscience, Inc MultiCodJ'-R Fx Herpes Simplex Virus I & 2 Kit. (K 100336). Table I compares the characteristics of the IM~x H-SV-1/2 for Abbott mn2000 assay (New Device) and the MultiCode'-RTx Herpes Si…
Eragen Biosciences2010—

Also cleared against K100336: 2 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172509Sentosa SA201 HSV 1/2 Qualitative PCR TestVela Diagnostics USA, Inc.20180
K142156Seegene Anyplex II HSV-1/2 AssaySeegene20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 12.5 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K172509 (Vela Diagnostics USA, Inc., 2018) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K100336.

How does its category compare?

All OQO devices

OQO Herpes Simplex Virus Nucleic Acid Amplification Assay: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · OQO

1in 2018

2010: 12011: 32014: 32015: 32017: 12018: 1
2007high 3 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OQO

140in 2015

2011: 81 days median2014: 87 days median2015: 140 days median
2007high 140 (2015) · low 81 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OQO

No recall names OQO since 2007.

Adverse event reports per year · OQO

1in 2025

2016: 62024: 22025: 1
2007high 6 (2016) · low 0 (2007)2025

MAUDE reports naming product code OQO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20101—00
201138100
20120—00
20130—00
201438700
2015314000
20160—06
20171—00
20181—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—02
20250—01
20260—0—

What is it indicated for?

The lMDx HSV-l/2 for Abbott m2000 assay is an in vitro diagnostic test for the direct, qualitative detection and differentiation of herpes simplex virus type I (HSV-l) and type 2 (HSV-2) DNA from male and female skin lesions from anogenital or oral sites. The test is intended for use as an aid in the diagnosis of HSV infection in symptomatic patients. The assay is intended to be run on the Abbott m;2000 instrument system.

Warning: The IMDx HSV 1/2 for Abbott m2000 assay is not FDA cleared for use with cerebrospinal fluid (CSF). The assay is not intended for prenatal screening.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K140198: Imdx HSV-1/2 for Abbott M2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140198

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026