510(k) Report

510(k) · Cleared

Cleared

1.5T Procure Array Coil, 3.0T Procure Array Coil

K140606510(k) SpecialCleared May 12, 201463-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Resonance Innovations, LLC · MOS Coil, Magnetic Resonance, Specialty

Cleared on May 12, 2014 as substantially equivalent to K022395 (Medic, Inc., 2002) after a 63-day review. Its family tree reaches back 2 generations to 1993. 9 later devices descend from it.

Decided
May 12, 2014
Review
63 days
Class
Class II
Product code
MOS
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K933659 (1993). 9 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2014: 2 descendants cleared2017: 1 descendant cleared2018: 1 descendant cleared2020: 2 descendants cleared2023: 1 descendant cleared2024: 2 descendants clearedK933659 · Model #100GE1500 Lower Extrem Quad Detect Array Coil · Medic, Inc. · 1993K022395 · 1.5T Scanmed PV Array · Medic, Inc. · 20021990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 2 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants K022395 · 1.5T Scanmed PV Array · Medic, Inc. · 2002K933659 · Model #100GE1500 Lower Extrem Quad Detect Array Coil · Medic, Inc. · 19930+5
  1. Root · 2 generations backK933659 Model #100GE1500 Lower Extrem Quad Detect Array CoilMedic, Inc. · 1993
  2. 1 generation backK022395 1.5T Scanmed PV ArrayMedic, Inc. · 2002
  3. This deviceK140606 1.5T Procure Array Coil, 3.0T Procure Array CoilResonance Innovations, LLC · 2014
  4. Descendant · cites it directly · 7 of its ownK142755 Siemens 3.0 Blanket Array CoilResonance Innovations, LLC · 2014
  5. Descendant · 2 generations on · 6 of its ownK173446 Contour 24Quality Electrodynamics, LLC · 2017
  6. Descendant · 3 generations on · 3 of its ownK183111 Contour 24Quality Electrodynamics, LLC · 2018
  7. Descendant · 4 generations on · 2 of its ownK223429 Contour KneeQuality Electrodynamics, LLC · 2023
  8. Descendant · 3 generations on · 1 of its ownK193140 Flex Body SPEEDERQuality Electrodynamics, LLC · 2020

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2014: 22017: 12018: 12020: 22023: 12024: 2
2014high 2 (2014) · low 0 (2015)2026

Most influential descendants

Showing 5 of 9 · See all
  • K142755Siemens 3.0 Blanket Array CoilResonance Innovations, LLC · 2014 · cites it directly7descendants
  • K173446Contour 24Quality Electrodynamics, LLC · 2017 · 2 generations on6descendants
  • K183111Contour 24Quality Electrodynamics, LLC · 2018 · 3 generations on3descendants
  • K223429Contour KneeQuality Electrodynamics, LLC · 2023 · 4 generations on2descendants
  • K193140Flex Body SPEEDERQuality Electrodynamics, LLC · 2020 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K933659Model #100GE1500 Lower Extrem Quad Detect Array CoilMedic, Inc.1993—
−1K0223951.5T Scanmed PV ArrayMedic, Inc.2002—
0 (this device)K1406061.5T Procure Array Coil, 3.0T Procure Array CoilResonance Innovations, LLC2014—
+1K142755Siemens 3.0 Blanket Array CoilResonance Innovations, LLC2014—
+2K173446Contour 24Quality Electrodynamics, LLC2017—
+3K183111Contour 24Quality Electrodynamics, LLC2018—
+4K223429Contour KneeQuality Electrodynamics, LLC2023—
+3K193140Flex Body SPEEDERQuality Electrodynamics, LLC2020—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201420
201710
201810
202020
202310
202420
FIG. 1 — Lineage of K140606, 1993–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOS device

  1. #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K0223951.5T Scanmed PV Array
Summary page 1
…Coil, Magnetic Resonance, Specialty Classification Code: MOS Predicate Device: 1.5T ScanMed'DPV Array, K022395 Description of the Device The PROCURETM Coil Family interfaces with a 1.5T or 3.OT 8-channel GE MR] scanner and provide…
Medic, Inc.2002—

What descends from it? (9)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142755Siemens 3.0 Blanket Array CoilResonance Innovations, LLC20147
K142676Siemens 3.0T PROCURE Array CoilResonance Innovations, LLC20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 2 companies; a new generation was cleared every 11.7 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K142755 (Resonance Innovations, LLC, 2014) has gone furthest, with 7 descendants of its own.

How does its category compare?

All MOS devices

MOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · MOS

3in 2025

2007: 162008: 192009: 102010: 162011: 252012: 152013: 72014: 122015: 62016: 112017: 92018: 102019: 32020: 52021: 42022: 112023: 102024: 102025: 32026 (partial year): 10
2007high 25 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOS

59in 2025

2007: 19 days median2008: 33 days median2009: 43 days median2010: 78 days median2011: 57 days median2012: 49 days median2013: 87 days median2014: 60 days median2015: 58 days median2016: 42 days median2017: 63 days median2018: 30 days median2019: 178 days median2020: 51 days median2021: 41 days median2022: 79 days median2023: 59 days median2024: 39 days median2025: 59 days median2026 (partial year): 45 days median
2007high 178 (2019) · low 19 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOS

13in 2024

2008: 22010: 12012: 12015: 22019: 82020: 12024: 13
2007high 13 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MOS

2in 2025

2007: 42008: 22009: 52010: 132011: 72012: 122013: 102014: 42015: 52016: 72017: 92018: 72019: 82020: 22021: 32022: 52023: 42024: 82025: 2
2007high 13 (2010) · low 2 (2008)2025

MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007161904
2008193322
2009104305
20101678113
2011255707
20121549112
2013787010
2014126004
201565825
2016114207
201796309
2018103007
2019317888
202055112
202144103
2022117905
2023105904
20241039138
202535902
202610450—

What is it indicated for?

The coil is indicated for use by the order of a physician to be used as an accessory to a General Electric 1.5T or 3.0T magnetic resonance scanner for general human anatomy imaging as supported by the scanner. These images, when interpreted by a trained physician, may assist in medical diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140606: 1.5T Procure Array Coil, 3.0T Procure Array Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K140606

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026