510(k) Report

510(k) · Cleared

Cleared

U-Type Contra Angle, U-Type Sectional Contra Angle

K141125510(k) TraditionalCleared Oct 23, 2014175-day reviewClass I21 CFR 872.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Handpiece Headquarters · EGS Handpiece, Contra- And Right-Angle Attachment, Dental

Cleared on Oct 23, 2014 as substantially equivalent to K073652 (Nakamura Magnifier Co., Ltd., 2008) after a 175-day review. Its family tree reaches back 3 generations to 1990.

Decided
Oct 23, 2014
Review
175 days
Class
Class I
Product code
EGS
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K896877 (1990). 8 ancestors in all, the oldest K790722 (1979). No later device cites it as a predicate yet.

  1. Root · 3 generations backK896877 Dental Air Motors (Several Models)Micro Motors, Inc. · 1990
  2. 2 generations backK070869 Prophy Star 3 Hygiene Handpiece, Model 264422Dentalez, Inc. · 2007
  3. 1 generation backK073652 ND Low Speed Airmotor and Handpiece, Highspeed Airturbine Handpiece…Nakamura Magnifier Co., Ltd. · 2008
  4. This deviceK141125 U-Type Contra Angle, U-Type Sectional Contra AngleHandpiece Headquarters · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K896877Dental Air Motors (Several Models)Micro Motors, Inc.1990—
−2K070869Prophy Star 3 Hygiene Handpiece, Model 264422Dentalez, Inc.2007—
−1K073652ND Low Speed Airmotor and Handpiece, Highspeed Airturbine Handpiece, E-Type…Nakamura Magnifier Co., Ltd.2008—
0 (this device)K141125U-Type Contra Angle, U-Type Sectional Contra AngleHandpiece Headquarters2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197920
198610
199010
199610
FIG. 1 — Lineage of K141125, 1990–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EGS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EGS device

  1. #1 K251869 Disposable Prophy Angle (3399-60, 3399-090…score 10.0 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073652ND Low Speed Airmotor and Handpiece, Highspeed Airturbine Handpiece, E-Type Straight…
Summary page 4
…ories. EGS e- Substantial Equivalency is claimed against the following devices: ND U-TYPE PROPHYLAXIS ANGLES (SEVERAL MODELS) NAKAMURA DENTAL HANDPIECE MFG. CO., LTD. - K073652 f- Description of the device: U-Type contra angles and U-Type sectional contra angles are used to mount on U-Type Nose Attachment…
Nakamura Magnifier Co., Ltd.2008—

Also cleared against K073652: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 6.6 years on median.
  • None of the 8 ancestors has a recall.
  • 2 other devices also cite its predicate K073652.

How does its category compare?

All EGS devices

EGS Handpiece, Contra- And Right-Angle Attachment, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · EGS

2in 2025

2007: 12009: 12010: 22011: 32012: 32013: 12014: 22015: 32017: 22018: 12019: 32020: 12021: 12022: 42023: 12024: 12025: 2
2007high 4 (2022) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EGS

189in 2022

2011: 104 days median2012: 288 days median2015: 245 days median2019: 276 days median2022: 189 days median
2007high 288 (2012) · low 104 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EGS

1in 2023

2023: 1
2007high 1 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EGS

82in 2025

2007: 22008: 142009: 452010: 742011: 22012: 32013: 22014: 382015: 1662016: 2992017: 3162018: 2302019: 2192020: 1912021: 2942022: 2792023: 1152024: 812025: 82
2007high 316 (2017) · low 2 (2007)2025

MAUDE reports naming product code EGS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
20080—014
20091—045
20102—074
2011310402
2012328803
20131—02
20142—038
201532450166
20160—0299
20172—0316
20181—0230
201932760219
20201—0191
20211—0294
202241890279
20231—1115
20241—081
20252—082
20260—0—

What is it indicated for?

The U-Type Contra Angles and U-Type Sectional Contra Angles are used to mount on

U-Type Nose Attachments and powered by either low speed air motors or electric micro

motors. These U-Type are intended for removing carious material, cavity and crown

preparations, finishing tooth preparations, reducing hard tooth structures, restorations and

polishing teeth.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141125: U-Type Contra Angle, U-Type Sectional Contra Angle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141125

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026