510(k) · Cleared
ClearedArthrex Pip Dart
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Arthrex, Inc. · HTY Pin, Fixation, Smooth
Cleared on Jul 18, 2014 as substantially equivalent to K050259 (Arthrex, Inc., 2005) after a 35-day review. Its family tree reaches back 1 generation to 2005.
- Decided
- Jul 18, 2014
- Review
- 35 days
- Class
- Class II
- Product code
- HTY
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K050259 (2005). No later device cites it as a predicate yet.
- Root · 1 generation backK050259 Arthrex Bio-PinArthrex, Inc. · 2005
- This deviceK141577 Arthrex Pip DartArthrex, Inc. · 2014
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K050259 | Arthrex Bio-Pin | Arthrex, Inc. | 2005 | — |
| 0 (this device) | K141577 | Arthrex Pip Dart | Arthrex, Inc. | 2014 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HTY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HTY device
- #1 K231272 OSSIOfiber® Pin Product Family, OSSIOfiber®…score 19.3 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K050259 | Arthrex Bio-PinSummary page 1…CFR fixation fastener Predicate Device K05 0259: Art hrex Blo-Pin Purpose of Submission This special 510(k) premarket notification is submitted to… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- 15 other devices also cite its predicate K050259.
How does its category compare?
All HTY devicesHTY Pin, Fixation, Smooth: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · HTY
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HTY
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HTY
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HTY
39in 2025
MAUDE reports naming product code HTY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 112 | 0 | 46 |
| 2008 | 6 | 86 | 0 | 38 |
| 2009 | 2 | — | 1 | 36 |
| 2010 | 9 | 180 | 1 | 33 |
| 2011 | 6 | 82 | 0 | 164 |
| 2012 | 4 | 76 | 0 | 129 |
| 2013 | 4 | 128 | 0 | 187 |
| 2014 | 8 | 73 | 0 | 149 |
| 2015 | 8 | 101 | 0 | 121 |
| 2016 | 6 | 114 | 2 | 128 |
| 2017 | 5 | 127 | 0 | 82 |
| 2018 | 4 | 162 | 0 | 138 |
| 2019 | 4 | 93 | 1 | 222 |
| 2020 | 5 | 108 | 0 | 210 |
| 2021 | 5 | 137 | 0 | 148 |
| 2022 | 4 | 121 | 2 | 96 |
| 2023 | 5 | 146 | 0 | 153 |
| 2024 | 1 | — | 0 | 297 |
| 2025 | 5 | 90 | 0 | 39 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
The Arthrex PIP Dart is intended to fix small bony or apical chondral fragments in the foot, ankle, upper extremities, hand, and wrist, where such fragments are not under tension or load-bearing. These devices are used in cases of osteochondritis dissecans and osteochondral fragments, fixation of fractures, 1st metatarsal (bunionectomy osteotomies), cuneiform bones, inherently stable osteotomies, and fusions of the phalanges, metatarsals, metacarpals…
Read the full statement (124 words)
The Arthrex PIP Dart is intended to fix small bony or apical chondral fragments in the foot, ankle, upper extremities, hand, and wrist, where such fragments are not under tension or load-bearing. These devices are used in cases of osteochondritis dissecans and osteochondral fragments, fixation of fractures, 1st metatarsal (bunionectomy osteotomies), cuneiform bones, inherently stable osteotomies, and fusions of the phalanges, metatarsals, metacarpals, carpal bones, tarsal bones, ankle, and wrist. The devices can be used for inherently stable intramedullary stabilization of joint arthroplasty (resection) or fusion for the treatment of digital deformities of the foot or hand. This device is also used in inherently stable long bone fractures such as the femur, fibula, tibia, radius and ulna, including the diaphyseal, epiphyseal, and metaphyseal areas.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K141577 · printed Nov 6, 2026
Cite this page
510(k) Report. “K141577: Arthrex Pip Dart.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141577
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026