510(k) · Cleared

Cleared

Polysyn Surgical Suture

K141625510(k) SpecialCleared Jul 18, 201431-day reviewClass II21 CFR 878.4493

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Surgical Specialties Corp · GAM Suture, Absorbable, Synthetic, Polyglycolic Acid

Cleared on Jul 18, 2014 as substantially equivalent to K965162 (Lukens Medical Corp., 1997) after a 31-day review. Its family tree reaches back 1 generation to 1997.

Decided
Jul 18, 2014
Review
31 days
Class
Class II
Product code
GAM
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K965162 (1997). No later device cites it as a predicate yet.

  1. Root · 1 generation backK965162 Lukens Pga, (Polyglycolic Acid) Synthetic Absorbable Surgical…Lukens Medical Corp. · 1997 · Recalled
  2. This deviceK141625 Polysyn Surgical SutureSurgical Specialties Corp · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K965162Lukens Pga, (Polyglycolic Acid) Synthetic Absorbable Surgical Suture,Coated…Lukens Medical Corp.19971
0 (this device)K141625Polysyn Surgical SutureSurgical Specialties Corp2014—
FIG. 1 — Lineage of K141625, 1997–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GAM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GAM device

  1. #1 K252743 STRATAFIX™ Spiral PDS™ Plus Knotless Tissue…score 14.8 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K965162Lukens Pga, (Polyglycolic Acid) Synthetic Absorbable Surgical Suture,Coated…
Summary page 1
…glycolic Acid Product code, 6AM 21 CFR 878.4493 Class 11 Legally marketed device K965 162: PolySynTM Surgical Suture (primary) to which the device is substantially equivalent: K022269 Coated VICRYLT…
Lukens Medical Corp.19971
†K022269Coated Vicryl* (Polyglactin 910) SutureETHICON, Inc.20023

Also cleared against K965162: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • 2 other devices also cite its predicate K965162.

How does its category compare?

All GAM devices

GAM Suture, Absorbable, Synthetic, Polyglycolic Acid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · GAM

3in 2025

2007: 72008: 62009: 32010: 12011: 22012: 52013: 12014: 102015: 52016: 32017: 82018: 52019: 42020: 32021: 22022: 22023: 12024: 22025: 32026 (partial year): 4
2007high 10 (2014) · low 1 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GAM

29in 2025

2007: 50 days median2008: 174 days median2009: 10 days median2012: 31 days median2014: 121 days median2015: 209 days median2016: 169 days median2017: 134 days median2018: 98 days median2019: 90 days median2020: 140 days median2025: 29 days median2026 (partial year): 131 days median
2007high 209 (2015) · low 10 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GAM

1in 2024

2007: 102008: 12009: 62010: 32011: 62016: 12017: 12019: 12020: 442022: 42024: 12026 (partial year): 2
2007high 44 (2020) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GAM

8,970in 2025

2007: 2742008: 1942009: 2872010: 5872011: 6372012: 8682013: 8982014: 1,4102015: 9352016: 1,1122017: 1,4992018: 2,2292019: 3,5642020: 3,4152021: 4,5062022: 4,8142023: 5,0702024: 7,2262025: 8,970
2007high 8,970 (2025) · low 194 (2008)2025

MAUDE reports naming product code GAM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200775010274
200861741194
20093106287
20101—3587
20112—6637
20125310868
20131—0898
20141012101,410
201552090935
2016316911,112
2017813411,499
201859802,229
201949013,564
20203140443,415
20212—04,506
20222—44,814
20231—05,070
20242—17,226
202532908,970
202641312—

What is it indicated for?

POLYSYNTM Polyglycolic Acid (PGA) Suture is indicated for use in general soft tissue approximation and/or ligation, including use in ophthalmic procedures, but not for use in Cardiovascular and Neurological procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141625: Polysyn Surgical Suture.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141625

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026