MEMO 3D ReChord

K142221510(k) SpecialCleared Aug 29, 201417-day reviewClass II21 CFR 870.3800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sorin Group Italia S.R.L. · KRH Ring, Annuloplasty

Cleared on Aug 29, 2014 as substantially equivalent to K071327 (Sorin Biomedica Cardio S.R.L., 2007) after a 17-day review. Its family tree reaches back 2 generations to 1993. 3 later devices descend from it.

Decided
Aug 29, 2014
Review
17 days
Class
Class II
Product code
KRH
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K926138 (1993). 5 ancestors in all. 3 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 2 other ancestors1997: 1 other ancestor2018: 1 descendant cleared2023: 1 descendant cleared2026: 1 descendant clearedK926138 · Carpentier-Edwards Physio Annuloplasty Ring · Baxter Healthcare Corp · 1993K071327 · Memo 3D Semirigid Annuloplasty Ring · Sorin Biomedica Cardio S.R.L. · 20071990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 3 other ancestors 1 generation forward: 2 descendants2 generations forward: 1 descendant K071327 · Memo 3D Semirigid Annuloplasty Ring · Sorin Biomedica Cardio S.R.L. · 2007K926138 · Carpentier-Edwards Physio Annuloplasty Ring · Baxter Healthcare Corp · 19930
  1. Root · 2 generations backK926138 Carpentier-Edwards Physio Annuloplasty RingBaxter Healthcare Corp · 1993
  2. 1 generation backK071327 Memo 3D Semirigid Annuloplasty RingSorin Biomedica Cardio S.R.L. · 2007
  3. This deviceK142221 MEMO 3D ReChordSorin Group Italia S.R.L. · 2014
  4. Descendant · cites it directly · 2 of its ownK180411 MEMO 4DSorin Group Italia S.R.L. · 2018
  5. Descendant · cites it directly · 1 of its ownK230318 Memo 3D Semirigid Annuloplasty Ring; Memo 3D ReChord Semirigid…Corcym S.r.l. · 2023
  6. Descendant · 2 generations on · 0 of its ownK261707 MEMO 4D Curve™ Semirigid mitral annuloplasty ringCorcym S.r.l. · 2026

Most influential descendants

Showing 3 of 3 · See all
  • K180411MEMO 4DSorin Group Italia S.R.L. · 2018 · cites it directly2descendants
  • K230318Memo 3D Semirigid Annuloplasty Ring; Memo 3D ReChord Semirigid Annuloplasty Ring; Memo…Corcym S.r.l. · 2023 · cites it directly1descendant
  • K261707MEMO 4D Curve™ Semirigid mitral annuloplasty ringCorcym S.r.l. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K926138Carpentier-Edwards Physio Annuloplasty RingBaxter Healthcare Corp1993—
−1K071327Memo 3D Semirigid Annuloplasty RingSorin Biomedica Cardio S.R.L.2007—
0 (this device)K142221MEMO 3D ReChordSorin Group Italia S.R.L.2014—
+1K180411MEMO 4DSorin Group Italia S.R.L.2018—
+1K230318Memo 3D Semirigid Annuloplasty Ring; Memo 3D ReChord Semirigid Annuloplasty…Corcym S.r.l.2023—
+2K261707MEMO 4D Curve™ Semirigid mitral annuloplasty ringCorcym S.r.l.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200220

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202310
202610
FIG. 1 — Lineage of K142221, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRH device

  1. #1 K261707 MEMO 4D Curve™ Semirigid mitral annuloplasty…score 12.7 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071327Memo 3D Semirigid Annuloplasty Ring
Summary page 4
…o its cleared predicate device identified below. Both devices have the same fundamental scientific technology and intended use: 510(k) Number: K071327 Proprietary Name: MEMO 3D Semirigid Annuloplasty Ring Common/Usual Name: Ring, Annuloplasty…
Sorin Biomedica Cardio S.R.L.2007—

Also cleared against K071327: 1 other device →

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K180411MEMO 4DSorin Group Italia S.R.L.20182
K230318Memo 3D Semirigid Annuloplasty Ring; Memo 3D ReChord Semirigid Annuloplasty Ring; Memo…Corcym S.r.l.20231

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 14.1 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K180411 (Sorin Group Italia S.R.L., 2018) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K071327.

How does its category compare?

All KRH devices

KRH Ring, Annuloplasty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · KRH

4in 2025

2007: 42008: 22009: 82010: 22011: 22014: 12016: 12018: 22019: 22020: 22023: 22024: 12025: 42026 (partial year): 2
2007high 8 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRH

98in 2025

2007: 90 days median2009: 68 days median2025: 98 days median
2007high 98 (2025) · low 68 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRH

No recall names KRH since 2007.

Adverse event reports per year · KRH

420in 2025

2007: 2612008: 1,2882009: 9732010: 6302011: 3212012: 902013: 972014: 732015: 1452016: 3472017: 3792018: 3782019: 3492020: 3402021: 4232022: 3722023: 3242024: 4072025: 420
2007high 1,288 (2008) · low 73 (2014)2025

MAUDE reports naming product code KRH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074900261
20082—01,288
20098680973
20102—0630
20112—0321
20120—090
20130—097
20141—073
20150—0145
20161—0347
20170—0379
20182—0378
20192—0349
20202—0340
20210—0423
20220—0372
20232—0324
20241—0407
20254980420
20262—0—

What is it indicated for?

MEMO 3D ReChord device is intended for correction of mitral insufficiencies or steno-insufficiences. The use of the MEMO 3D ReChord device is indicated for correction of congenital or acquired mitral insufficiencies with dilatation and deformation of the mitral annulus. Type I insufficiencies, with no manifest lesions in the subvalvular apparatus, can be treated with the implant of the annuloplasty ring on its own. For type II insufficiencies…

Read the full statement (108 words)

MEMO 3D ReChord device is intended for correction of mitral insufficiencies or steno-insufficiences.

The use of the MEMO 3D ReChord device is indicated for correction of congenital or acquired mitral insufficiencies with dilatation and deformation of the mitral annulus. Type I insufficiencies, with no manifest lesions in the subvalvular apparatus, can be treated with the implant of the annuloplasty ring on its own. For type II insufficiencies, characterised by valve prolapse sustained by elongation/ breakage of the chordae tendineae and papillary muscles, and type III insufficiencies, characterised by partially immobilised leaflets due to the fusion/hypertrophy of the chordae tendineae, the device implantation must be accompanied by corrective valvuloplasty.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K142221: MEMO 3D ReChord.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142221

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026