510(k) Report

510(k) · Cleared

Cleared

NeumoFilt Ergo/Neumo Filt BiteOn

K142303510(k) TraditionalCleared Nov 20, 201494-day reviewClass II21 CFR 868.1840

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical Respiratory Devices S.L. · BZG Spirometer, Diagnostic

Cleared on Nov 20, 2014 as substantially equivalent to K051712 (Air Safety, Ltd., 2005) after a 94-day review. Its family tree reaches back 3 generations to 1993.

Decided
Nov 20, 2014
Review
94 days
Class
Class II
Product code
BZG
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K934475 (1993). No later device cites it as a predicate yet.

  1. Root · 3 generations backK934475 Koko Filter IIPulmonary Data Services Inst., Inc. · 1993
  2. 2 generations backK013123 Ems Pulmonary Function Testing FilterEngineered Medical Systems · 2002
  3. 1 generation backK051712 Model 2800 PFT FilterAir Safety, Ltd. · 2005
  4. This deviceK142303 NeumoFilt Ergo/Neumo Filt BiteOnMedical Respiratory Devices S.L. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K934475Koko Filter IIPulmonary Data Services Inst., Inc.1993—
−2K013123Ems Pulmonary Function Testing FilterEngineered Medical Systems2002—
−1K051712Model 2800 PFT FilterAir Safety, Ltd.2005—
0 (this device)K142303NeumoFilt Ergo/Neumo Filt BiteOnMedical Respiratory Devices S.L.2014—
FIG. 1 — Lineage of K142303, 1993–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZG device

  1. #1 K251777 MESI mTABLET SPIROscore 13.0 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K051712Model 2800 PFT Filter
Summary page 5
…number: 21 CFR 868.1840 Device class: Class II Predicate Device: Air Safety Model 2800 PFT filter (K051712) Device Description: The MRD NeumoFilt pulmonary function filter (“PFT filter”) is a standard electrostatic filter that is place…
Air Safety, Ltd.2005—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 4 companies; a new generation was cleared every 8.4 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All BZG devices

BZG Spirometer, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · BZG

2in 2024

2007: 32008: 32009: 82010: 42011: 62012: 32013: 32014: 52015: 52016: 42017: 22018: 12019: 32020: 52021: 12022: 22023: 52024: 22026 (partial year): 1
2007high 8 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZG

362in 2023

2007: 121 days median2008: 209 days median2009: 141 days median2010: 181 days median2011: 278 days median2012: 59 days median2013: 266 days median2014: 154 days median2015: 273 days median2016: 235 days median2019: 146 days median2020: 126 days median2023: 362 days median
2007high 362 (2023) · low 59 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZG

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BZG

1in 2025

2007: 12011: 12012: 22013: 12014: 12015: 12016: 12017: 12018: 12019: 12020: 22021: 12022: 32023: 22024: 32025: 1
2007high 3 (2022) · low 0 (2008)2025

MAUDE reports naming product code BZG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007312101
2008320900
2009814100
2010418100
2011627801
201235902
2013326601
2014515401
2015527301
2016423501
20172—01
20181—01
2019314601
2020512602
20211—01
20222—03
2023536202
20242—13
20250—01
20261—0—

What is it indicated for?

For use with pulmonary function testing (PFT) equipment only, to filter air between the patient’s exhaled air and the testing equipment. Single patient use, disposable. Duration of use <24 hours. Environment of use: Hospital, Sub-acute facilities, Clinics, Physician offices.

For use with pulmonary function testing (PFT) equipment only, to filter air between the patient’s exhaled air and the testing equipment. Single patient use, disposable. Duration of use <24 hours. Environment of use: Hospital, Sub-acute facilities, Clinics, Physician offices.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K142303: NeumoFilt Ergo/Neumo Filt BiteOn.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142303

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026