# K142345: Talos-C (HA) Cervical Intervertebral Body Fusion Devices

- Pathway: 510(k) (Traditional)
- Applicant: Meditech Spine, LLC
- Decided: Feb 22, 2015 after 184 days
- Product code: ODP (Intervertebral Fusion Device With Bone Graft, Cervical)
- Device class: 2
- Regulation: 21 CFR 888.3080
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 1 generation back to K122850 (2013). 1 ancestor in all.
239 later devices descend from it; 4 cite it directly.
0 of 241 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K122850: Talos-C Cervical Intervertebral Body Fusion Devices, Meditech Advisors, LLC (2013) Summary page 4.

## Most influential descendants
- K150788: Talos Intervertebral Body Fusion Devices, Talos -C Cervical Intervertebral Body Fusion Devices, Talos -C (HA) Cervical Intervertebral Body Fusion Devices (2015), 202 descendants of its own
- K160924: Amendia Interbody Fusion Devices (2016), 166 descendants of its own
- K171496: Tritanium C Anterior Cervical Cage (2017), 129 descendants of its own
- K180364: HD LifeSciences Cervical IBFD System (2018), 106 descendants of its own
- K183557: Endoskeleton® TA Interbody Fusion Device, Endoskeleton® TAS Interbody Fusion Device, Endoskeleton® TO Interbody Fusion Device, Endoskeleton® TT Interbody Fusion Device, Endoskeleton® TC Interbody Fusion Device, Endoskeleton® TCS Interbody Fusion Device, Endoskeleton® TL Interbody Fusion Device, Endoskeleton® TA Vertebral Body Replacement (VBR) Device (2019), 104 descendants of its own

## Indications for use
Talos®-C (HA) Cervical Intervertebral Body Fusion Devices are intervertebral body devices intended for use in skeletally mature patients with Degenerative Disc Disease (DDD) of the cervical spine at one level from C2-T1. Cervical degenerative disc disease is defined as intractable radiculopathy and/or myelopathy with herniated disc and/or osteophyte formation on the posterior vertebral endplates producing symptomatic nerve root and/or spinal cord compression confirmed by history and radiographic studies. Talos®-C (HA) Cervical IBF Devices are intended to be used with autologous bone graft to facilitate fusion. Non-operative treatment prior to treatment with Talos®-C (HA) Cervical Intervertebral Body Fusion Devices is six (6) weeks. Talos®-C (HA) Cervical IBF Devices are to be implanted via an open anterior approach. Talos®-C (HA) Cervical IBF Devices are also to be used with supplemental fixation.

Source page: https://510kreport.com/device/K142345