510(k) Report

510(k) · Cleared

Cleared

Osstell IDx

K142358510(k) TraditionalCleared Feb 19, 2015178-day reviewClass I21 CFR 872.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Osstell AB · EKX Handpiece, Direct Drive, Ac-Powered

Cleared on Feb 19, 2015 as substantially equivalent to K082523 (Osstell AB, 2008) after a 178-day review. Its family tree reaches back 3 generations to 2001.

Decided
Feb 19, 2015
Review
178 days
Class
Class I
Product code
EKX
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K003714 (2001). No later device cites it as a predicate yet.

  1. Root · 3 generations backK003714 Osstell Resonance Frequency AnalyzerIntegration Diagnostics, Ltd. · 2001
  2. 2 generations backK033689 Osstell Mentor RfaIntegration Diagnostics, Ltd. · 2004
  3. 1 generation backK082523 Osstell Isq Implant Stability MeterOsstell AB · 2008
  4. This deviceK142358 Osstell IDxOsstell AB · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K003714Osstell Resonance Frequency AnalyzerIntegration Diagnostics, Ltd.2001—
−2K033689Osstell Mentor RfaIntegration Diagnostics, Ltd.2004—
−1K082523Osstell Isq Implant Stability MeterOsstell AB2008—
0 (this device)K142358Osstell IDxOsstell AB2015—
FIG. 1 — Lineage of K142358, 2001–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EKX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EKX device

  1. #1 K261987 Reusable SmartPegscore 13.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082523Osstell Isq Implant Stability Meter
Summary page 4
…umber: Regulation Name: Device Description: 2014-08-22 Osstell IDx Dental implant stability analyzer Class I EKX - handpiece, direct drive, ac-powered Osstell 1SQ (K082523) 21 CFR 872.4200 Dental handpiece and accessories The Osstell 1Dx is a modification of the Osstell ISQ (K082523). The system i…
Osstell AB2008—

Also cleared against K082523: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 4.6 years on median.
  • None of the 3 ancestors has a recall.
  • 4 other devices also cite its predicate K082523.

How does its category compare?

All EKX devices

EKX Handpiece, Direct Drive, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · EKX

5in 2025

2007: 12008: 32009: 42010: 32011: 42012: 22013: 22014: 32015: 32016: 32017: 22018: 32019: 32020: 12021: 52022: 32023: 42024: 42025: 52026 (partial year): 1
2007high 5 (2021) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EKX

244in 2025

2008: 101 days median2009: 186 days median2010: 114 days median2011: 75 days median2014: 251 days median2015: 178 days median2016: 274 days median2018: 293 days median2019: 349 days median2021: 214 days median2022: 359 days median2023: 152 days median2024: 276 days median2025: 244 days median
2007high 359 (2022) · low 75 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EKX

No recall names EKX since 2007.

Adverse event reports per year · EKX

9in 2025

2007: 92008: 102009: 112010: 202011: 62012: 272013: 452014: 1022015: 682016: 662017: 102018: 492019: 562020: 672021: 792022: 372023: 142024: 192025: 9
2007high 102 (2014) · low 6 (2011)2025

MAUDE reports naming product code EKX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—09
20083101010
20094186011
20103114020
201147506
20122—027
20132—045
201432510102
20153178068
20163274066
20172—010
20183293049
20193349056
20201—067
20215214079
20223359037
20234152014
20244276019
2025524409
20261—0—

What is it indicated for?

The Osstell IDx is indicated for use in measuring the stability of implants in the oral cavity and maxillofacial region.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K142358: Osstell IDx.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142358

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026