510(k) · Cleared
ClearedIRIDEX CycloG6 Laser System, MicroPulse P3 Drive, G-Probe (RFID)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Iridex Corporation · GEX Powered Laser Surgical Instrument
Cleared on Jan 2, 2015 as substantially equivalent to K071687 (Iridex Corp, 2008) after a 60-day review. Its family tree reaches back 1 generation to 2008. 3 later devices descend from it.
- Decided
- Jan 2, 2015
- Review
- 60 days
- Class
- Class II
- Product code
- GEX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K071687 (2008). 3 later devices descend from it, 3 citing it directly.
- Root · 1 generation backK071687 Famili of Iridex IQ Laser SystemsIridex Corp · 2008
- This deviceK143154 IRIDEX CycloG6 Laser System, MicroPulse P3 Drive, G-Probe (RFID)Iridex Corporation · 2015
- Descendant · cites it directly · 1 of its ownK162416 IRIDEX Cyclo G6 Laser System, G-Probe IlluminateIridex Corporation · 2016
- Descendant · cites it directly · 0 of its ownK213592 Iridex 810 LaserIridex Corporation · 2022
- Descendant · cites it directly · 0 of its ownK163632 Katalyst Cyclophotocoagulation ProbeKatalyst Surgical, LLC · 2017
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K071687 | Famili of Iridex IQ Laser Systems | Iridex Corp | 2008 | — |
| 0 (this device) | K143154 | IRIDEX CycloG6 Laser System, MicroPulse P3 Drive, G-Probe (RFID) | Iridex Corporation | 2015 | — |
| +1 | K162416 | IRIDEX Cyclo G6 Laser System, G-Probe Illuminate | Iridex Corporation | 2016 | — |
| +1 | K213592 | Iridex 810 Laser | Iridex Corporation | 2022 | — |
| +1 | K163632 | Katalyst Cyclophotocoagulation Probe | Katalyst Surgical, LLC | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEX device
- #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K071687 | Famili of Iridex IQ Laser SystemsSummary page 4…Cyclo G6 Primary Classification Name(s): Electrosurgical cutting and coagulation device and accessories III. Predicate Devices K071687 – Family of Iridex IQ Laser Systems (IQ 532, IQ 577, IQ 630-670, IQ 810) Premarket Notificatio… | 2008 |
What descends from it? (3)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All GEX devicesGEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · GEX
83in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEX
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEX
3in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GEX
2,720in 2025
MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 73 | 79 | 9 | 342 |
| 2008 | 107 | 86 | 2 | 232 |
| 2009 | 69 | 100 | 0 | 209 |
| 2010 | 50 | 96 | 4 | 1,711 |
| 2011 | 41 | 83 | 18 | 3,024 |
| 2012 | 45 | 118 | 5 | 2,000 |
| 2013 | 46 | 144 | 3 | 2,236 |
| 2014 | 61 | 147 | 6 | 2,036 |
| 2015 | 47 | 112 | 0 | 2,099 |
| 2016 | 51 | 114 | 1 | 2,585 |
| 2017 | 67 | 90 | 5 (1) | 2,977 |
| 2018 | 51 | 78 | 5 | 3,525 |
| 2019 | 41 | 88 | 6 | 2,709 |
| 2020 | 52 | 90 | 1 | 2,183 |
| 2021 | 53 | 123 | 0 | 3,465 |
| 2022 | 60 | 152 | 0 | 2,288 |
| 2023 | 52 | 87 | 6 | 2,337 |
| 2024 | 82 | 90 | 3 | 2,187 |
| 2025 | 83 | 90 | 0 | 2,720 |
| 2026 | 57 | 90 | 2 | — |
What is it indicated for?
The Family of IRIDEX® IQ Laser Systems (IQ 532 [532nm], IQ 577 [577nm], IQ 630-670 [630nm-670nm], IQ 810 [810nm] [IRIDEX Cyclo G6 Laser System]) and the hand pieces, delivery devices & accessories that are used with them to deliver laser energy in either CW-pulse, MicroPulse™ or LongPulse™ mode. Intended for soft and fibrous tissue, including osseous tissue incision, excision, coagulation, vaporization, ablation and vessel hemostasis in the medical…
Read the full statement (168 words)
The Family of IRIDEX® IQ Laser Systems (IQ 532 [532nm], IQ 577 [577nm], IQ 630-670 [630nm-670nm], IQ 810 [810nm] [IRIDEX Cyclo G6 Laser System]) and the hand pieces, delivery devices & accessories that are used with them to deliver laser energy in either CW-pulse, MicroPulse™ or LongPulse™ mode. Intended for soft and fibrous tissue, including osseous tissue incision, excision, coagulation, vaporization, ablation and vessel hemostasis in the medical specialties of, dermatology, ear, nose and throat (ENT)/ otolaryngology, and ophthalmology as follows:
810nm (IRIDEX Cyclo G6 Laser System)
Ophthalmology:
The IRIDEX® Cyclo G6 Laser System and Probe Delivery Devices (G-Probe & MicroPulse P3) are used to deliver laser energy in either CW-Pulse (CW) or MicroPulse™ (µP) treatment mode and indicated for the treatment of Glaucoma:
MicroPulse P3 Device: For the treatment of Glaucoma including: Primary Open-Angle, Closed-Angle, Refractory. Treatment: Transscleral cyclophotocoagulation (TSCPC) of the ciliary processes. CW/µP: µP.
G-Probe: For the treatment of Glaucoma including: Primary Open-Angle, Closed-Angle, Refractory. Treatment: Transscleral cyclophotocoagulation (TSCPC) of the ciliary processes. CW/µP: CW.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K143154 · printed Nov 6, 2026
Cite this page
510(k) Report. “K143154: IRIDEX CycloG6 Laser System, MicroPulse P3 Drive, G-Probe (RFID).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K143154
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026