510(k) Report

510(k) · Cleared

Cleared

Audit MicroControls Linearity FD Tumor Markers II

K143573510(k) TraditionalCleared Jan 16, 201530-day reviewClass I21 CFR 862.1660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aalto Scientific, Ltd. · JJY Multi-Analyte Controls, All Kinds (Assayed)

Cleared on Jan 16, 2015 as substantially equivalent to K082717 (Aalto Scientific, Ltd., 2008) after a 30-day review. Its family tree reaches back 4 generations to 1991.

Decided
Jan 16, 2015
Review
30 days
Class
Class I
Product code
JJY
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K910440 (1991). No later device cites it as a predicate yet.

  1. Root · 4 generations backK910440 Document Reflectance II Linearity Test SetCasco Standards · 1991
  2. 3 generations backK023410 Validate Chem 10 Calibration Verification Test Set, Model 110Maine Standards Co. · 2003
  3. 2 generations backK042318 Audit Microcv General Chemistry Linearity SetAalto Scientific, Ltd. · 2004
  4. 1 generation backK082717 Audit Microcv Tumor Markers Linearity Set, Model K719M-5Aalto Scientific, Ltd. · 2008
  5. This deviceK143573 Audit MicroControls Linearity FD Tumor Markers IIAalto Scientific, Ltd. · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K910440Document Reflectance II Linearity Test SetCasco Standards1991—
−3K023410Validate Chem 10 Calibration Verification Test Set, Model 110Maine Standards Co.2003—
−2K042318Audit Microcv General Chemistry Linearity SetAalto Scientific, Ltd.2004—
−1K082717Audit Microcv Tumor Markers Linearity Set, Model K719M-5Aalto Scientific, Ltd.2008—
0 (this device)K143573Audit MicroControls Linearity FD Tumor Markers IIAalto Scientific, Ltd.2015—
FIG. 1 — Lineage of K143573, 1991–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082717Audit Microcv Tumor Markers Linearity Set, Model K719M-5
Summary page 4
…Class I, Reserved Product Code: JJY Regulation Number: 21CFR862.1660 C. Device to Which Substantial Equivalence is Claimed K082717 Audit® MicroCV™ Tumor Markers Linearity Set D. Intended Use Page 1 of 6 === Pa…
Aalto Scientific, Ltd.2008—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 3 companies; a new generation was cleared every 6.2 years on median.
  • None of the 4 ancestors has a recall.

How does its category compare?

All JJY devices

JJY Multi-Analyte Controls, All Kinds (Assayed): FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · JJY

3in 2017

2007: 112008: 72009: 82010: 102011: 142012: 132013: 162014: 102015: 42016: 12017: 3
2007high 16 (2013) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJY

78in 2017

2007: 49 days median2008: 54 days median2009: 80 days median2010: 109 days median2011: 120 days median2012: 40 days median2013: 82 days median2014: 49 days median2015: 153 days median2017: 78 days median
2007high 153 (2015) · low 40 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJY

2in 2025

2007: 52009: 22010: 62011: 12012: 32013: 22014: 22015: 12016: 32017: 42018: 32019: 42020: 62022: 32023: 32025: 22026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJY

13in 2025

2007: 22008: 12009: 32010: 32011: 62012: 202013: 52014: 42015: 42016: 132017: 122018: 72019: 12020: 72021: 12023: 42024: 12025: 13
2007high 20 (2012) · low 0 (2022)2025

MAUDE reports naming product code JJY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007114952
200875401
200988023
20101010963
20111412016
20121340320
2013168225
2014104924
2015415314
20161—313
2017378412
20180—37
20190—41
20200—67
20210—01
20220—30
20230—34
20240—01
20250—213
20260—1—

What is it indicated for?

The Linearity FD Tumor Markers II is an assayed quality control material intended to simulate human patient samples for use in determining linearity, calibration verification, and the verification of reportable range for the following analytes: Alpha fetoprotein (AFP), Carcinoembryonic antigen (CEA), Prostate-specific antigen-total (PSA), Carbonic Anhydrase-125 (CA-125), Carbonic Anhydrase 19-9 (CA19-9), Carbonic Anhydrase 27-29 (CA27-29)/(BR), free-PSA (fPSA), and Carbonic Anhydrase 15-3 (CA15-3).

The Linearity FD Tumor Markers II is for In Vitro Diagnostic use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K143573: Audit MicroControls Linearity FD Tumor Markers II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K143573

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026