510(k) Report

510(k) · Cleared

Recalled · Class II · 2016

GEM Flow COUPLER Device and System

K143589510(k) SpecialCleared Jan 16, 201529-day reviewClass II21 CFR 878.4300Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Synovis Life Technologies, Inc. · MVR Device, Anastomotic, Microvascular

Cleared on Jan 16, 2015 as substantially equivalent to K142309 (Synovis Life Technologies, Inc., 2014) after a 29-day review. Its family tree reaches back 3 generations to 2010. 2 later devices descend from it. It has been recalled 2 times.

Decided
Jan 16, 2015
Review
29 days
Class
Class II
Product code
MVR
Recalls
2
Predicates
1

Its longest line of descent runs back 3 generations to K093310 (2010). 2 later devices descend from it, 2 citing it directly.

  1. Root · 3 generations backK093310 Gem Flow Coupler Device and SystemSynovis Micro Companies Alliance, Inc. · 2010
  2. 2 generations backK132727 Gem Flow Coupler Device and SystemSynovis Life Technologies, Inc. · 2013 · Recalled
  3. 1 generation backK142309 GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc. · 2014
  4. This deviceK143589 GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc. · 2015
  5. Descendant · cites it directly · 0 of its ownK233394 Gem Flow Now (GEM2770-FN)Synovis Micro Companies Alliance · 2024
  6. Descendant · cites it directly · 0 of its ownK190499 Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc. · 2019

Most influential descendants

Showing 2 of 2 · See all
  • K233394Gem Flow Now (GEM2770-FN)Synovis Micro Companies Alliance · 2024 · cites it directly0descendants
  • K190499Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc. · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K093310Gem Flow Coupler Device and SystemSynovis Micro Companies Alliance, Inc.2010—
−2K132727Gem Flow Coupler Device and SystemSynovis Life Technologies, Inc.20135
−1K142309GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc.2014—
0 (this device)K143589GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc.2015—
+1K233394Gem Flow Now (GEM2770-FN)Synovis Micro Companies Alliance2024—
+1K190499Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc.2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202410
FIG. 1 — Lineage of K143589, 2010–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MVR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K142309GEM Flow COUPLER Device and System
Our reading of the summary gave K142609, FDA’s number for CR3 Keyless Split Sample Cup Nortriptyline-Buprenorphine (Guangzhou Wondfo Biotech Co., Ltd.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “GEM Flow COUPLER Device and System”.
Synovis Life Technologies, Inc.2014—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233394Gem Flow Now (GEM2770-FN)Synovis Micro Companies Alliance20240
K190499Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc.20190

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 21, 2016Class IIZ-1631-2016Package design/selectionInstructions for use booklet may puncture the outer Tyvek lid.
Apr 21, 2016Class IIZ-1630-2016Package design/selectionInstructions for use booklet may puncture the outer Tyvek lid.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 11 months on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K233394 (Synovis Micro Companies Alliance, 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MVR devices

MVR Device, Anastomotic, Microvascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · MVR

2in 2019

2009: 12010: 12013: 12014: 12015: 12019: 2
2007high 2 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MVR

Too few MVR 510(k)s in any year since 2007 to give a median.

Recalls per year · MVR

1in 2020

2008: 12020: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MVR

91in 2025

2007: 12008: 122009: 232010: 312011: 282012: 292013: 212014: 262015: 402016: 222017: 132018: 132019: 442020: 432021: 352022: 182023: 282024: 382025: 91
2007high 91 (2025) · low 1 (2007)2025

MAUDE reports naming product code MVR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—112
20091—023
20101—031
20110—028
20120—029
20131—021
20141—026
20151—040
20160—022
20170—013
20180—013
20192—044
20200—143
20210—035
20220—018
20230—028
20240—038
20250—091
20260—0—

What is it indicated for?

The Flow COUPLER Device is a single use, implantable device that is intended to be used in the end-to-end anastomosis of veins and arteries normally encountered in microsurgical and vascular reconstructive procedures. The Flow COUPLER Device includes a pair of permanently implanted rings which secure the anastomosis and a removable Doppler probe that is press-fit onto one of the rings. When the Flow COUPLER Device is used in conjunction with the Flow…

Read the full statement (133 words)

The Flow COUPLER Device is a single use, implantable device that is intended to be used in the end-to-end anastomosis of veins and arteries normally encountered in microsurgical and vascular reconstructive procedures. The Flow COUPLER Device includes a pair of permanently implanted rings which secure the anastomosis and a removable Doppler probe that is press-fit onto one of the rings. When the Flow COUPLER Device is used in conjunction with the Flow COUPLER Monitor, the Flow COUPLER System is intended to detect blood flow and confirm vessel patency intra-operatively and post-operatively at the anastomotic site. Post-operatively, blood flow can be detected on an as needed basis for up to 7 days. The Flow COUPLER Doppler probe is not intended to be a permanent implant and should be removed 3 to 14 days post-operatively.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K143589: GEM Flow COUPLER Device and System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K143589

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026