510(k) · Cleared
ClearedOxyless Blood Tubing Set
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Oxyless, Ltd. · FJK Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
Cleared on Feb 24, 2016 as substantially equivalent to K072024 (Nipro Medical Corp., 2007) after a 383-day review. Its family tree reaches back 2 generations to 2001.
- Decided
- Feb 24, 2016
- Review
- 383 days
- Class
- Class II
- Product code
- FJK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K010264 (2001). No later device cites it as a predicate yet.
- Root · 2 generations backK010264 Nipro Blood Tubing Set for Hemodialysis with Transducer Protectors…Nipro Medical Corp. · 2001
- 1 generation backK072024 Nipro Blood Tubing Set with Transducer Protector and Priming Set…Nipro Medical Corp. · 2007 · Recalled
- This deviceK150304 Oxyless Blood Tubing SetOxyless, Ltd. · 2016
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K010264 | Nipro Blood Tubing Set for Hemodialysis with Transducer Protectors and Priming… | Nipro Medical Corp. | 2001 | — |
| −1 | K072024 | Nipro Blood Tubing Set with Transducer Protector and Priming Set, Model… | Nipro Medical Corp. | 2007 | 1 |
| 0 (this device) | K150304 | Oxyless Blood Tubing Set | Oxyless, Ltd. | 2016 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FJK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FJK device
- #1 K252423 NovaLine Tubing Set for Hemodialysis (BL 124)score 12.2 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K072024 | Nipro Blood Tubing Set with Transducer Protector and Priming Set, Model A201-A219…Summary page 4…ccessories Product Code: FJK 21CFR 807.92 (a)(3) PREDICATE DEVICE The predicate for the Oxyless Blood Tubing Set is the: Nipro Blood Tubing Set cleared under 510(k) K072024: a. Device Proprietary Name: Blood Tubing Set with Transducer Protector and Priming Set b. Manuf… | 2007 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 2 companies; a new generation was cleared every 8.4 years on median.
- 1 of the 2 ancestors has a recall of any class.
- 5 other devices also cite its predicate K072024.
How does its category compare?
All FJK devicesFJK Set, Tubing, Blood, With And Without Anti-Regurgitation Valve: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · FJK
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FJK
255in 2021
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FJK
1in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · FJK
1,487in 2025
MAUDE reports naming product code FJK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 116 | 2 | 135 |
| 2008 | 1 | — | 2 | 86 |
| 2009 | 1 | — | 0 | 76 |
| 2010 | 1 | — | 2 | 130 |
| 2011 | 0 | — | 0 | 243 |
| 2012 | 2 | — | 0 | 35 |
| 2013 | 0 | — | 0 | 114 |
| 2014 | 1 | — | 0 | 116 |
| 2015 | 0 | — | 1 | 126 |
| 2016 | 1 | — | 0 | 139 |
| 2017 | 1 | — | 0 | 131 |
| 2018 | 1 | — | 0 | 119 |
| 2019 | 0 | — | 0 | 185 |
| 2020 | 0 | — | 1 | 190 |
| 2021 | 3 | 255 | 0 | 188 |
| 2022 | 0 | — | 0 | 362 |
| 2023 | 1 | — | 0 | 585 |
| 2024 | 1 | — | 0 | 417 |
| 2025 | 1 | — | 1 (1) | 1,487 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
The Oxyless Blood Tubing set with transducer protector and optional priming set comprises disposable blood tubing lines intended to provide extracorporeal access to the patient’s blood during hemodialysis. This blood tubing set is indicated for use with a medically prescribed hemodialyzer. The compatibility of available configurations is the responsibility of the physician in charge.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K150304 · printed Nov 6, 2026
Cite this page
510(k) Report. “K150304: Oxyless Blood Tubing Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150304
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026