510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Cortisol Saliva Luminescence Immunoassay

K150528510(k) TraditionalCleared Nov 25, 2015268-day reviewClass II21 CFR 862.1205Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ibl International GmbH · NHG Enzyme Immunoassay, Cortisol, Salivary

Cleared on Nov 25, 2015 as substantially equivalent to K102841 (Pantex, Div. Bio-Analysis, Inc., 2012) after a 268-day review. Its family tree reaches back 2 generations to 2001. It has been recalled once.

Decided
Nov 25, 2015
Review
268 days
Class
Class II
Product code
NHG
Recalls
1
Predicates
1

Its longest line of descent runs back 2 generations to K011323 (2001). No later device cites it as a predicate yet.

  1. Root · 2 generations backK011323 High Sensitivity Cortisol Enzyme Immunoassay, Model 1-0101/1-0102Salimetrics, LLC · 2001
  2. 1 generation backK102841 Pantex AM/PM Salivary Cortisol Enzyme ImmunoassayPantex, Div. Bio-Analysis, Inc. · 2012
  3. This deviceK150528 Cortisol Saliva Luminescence ImmunoassayIbl International GmbH · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K011323High Sensitivity Cortisol Enzyme Immunoassay, Model 1-0101/1-0102Salimetrics, LLC2001—
−1K102841Pantex AM/PM Salivary Cortisol Enzyme ImmunoassayPantex, Div. Bio-Analysis, Inc.2012—
0 (this device)K150528Cortisol Saliva Luminescence ImmunoassayIbl International GmbH2015—
FIG. 1 — Lineage of K150528, 2001–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102841Pantex AM/PM Salivary Cortisol Enzyme Immunoassay
Summary page 5
…tisone and hydroxycorticosterone) test system Classification Regulation: 862.1205 Product Code: NHG 6. Predicate Device Pantex INC. AM/PM Salivary cortisol EIA k102841. 7. Device Description Summary and explanation: Cortisol (also known as hydrocortisone, compound F) is the main glucoco…
Pantex, Div. Bio-Analysis, Inc.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 12, 2018Class IIZ-2923-2018Nonconforming Material/ComponentProduct is not meeting specification for traceability to NIST cortisol standard, generating 1.3-1.8 times higher cortisol values with laboratory samples in comparison to NIST cortisol standard.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 10.4 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All NHG devices

NHG Enzyme Immunoassay, Cortisol, Salivary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · NHG

1in 2015

2007: 12012: 12015: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHG

Too few NHG 510(k)s in any year since 2007 to give a median.

Recalls per year · NHG

3in 2025

2007: 12025: 3
2007high 3 (2025) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NHG

1in 2024

2011: 22012: 12013: 12014: 12015: 12016: 72017: 12018: 12019: 12021: 22023: 12024: 1
2007high 7 (2016) · low 0 (2007)2025

MAUDE reports naming product code NHG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—10
20080—00
20090—00
20100—00
20110—02
20121—01
20130—01
20140—01
20151—01
20160—07
20170—01
20180—01
20190—01
20200—00
20210—02
20220—00
20230—01
20240—01
20250—30
20260—0—

What is it indicated for?

The IBL International Cortisol Saliva Luminescence Immunoassay is intended for the in-vitro diagnostic quantitative determination of Cortisol in human saliva and for use as an aid in the diagnosis and treatment of adrenal disorders.

The device is not intended for point-of-care settings.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K150528: Cortisol Saliva Luminescence Immunoassay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150528

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026