Skeletal Dynamics, LLC · HRS Plate, Fixation, Bone
Cleared on May 12, 2015 as substantially equivalent to K093761 (Biomet Trauma (Aka Ebi, Lp), 2010) after a 57-day review. Its family tree reaches back 3 generations to 2000. 1 later device descends from it.
- Decided
- May 12, 2015
- Review
- 57 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K000684 (2000). 16 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backK000684 Small Fragment Dynamic Compression Locking (DCL) SystemSynthes (Usa) · 2000 · Recalled
- 2 generations backK011335 Synths One-Third Tubular DCL PlateSynthes (Usa) · 2001 · Recalled
- 1 generation backK093761 Optilock VL (Variable Angle Locking) Distal Radius Plating SystemBiomet Trauma (Aka Ebi, Lp) · 2010
- This deviceK150675 Dorsal Spanning PlateSkeletal Dynamics, LLC · 2015
- Descendant · cites it directly · 0 of its ownK212601 DRPx Locking Distal Radius Plate SystemOrthopaedic Implant Company · 2022
Most influential descendants
Showing 1 of 1 · See all- K212601DRPx Locking Distal Radius Plate SystemOrthopaedic Implant Company · 2022 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K000684 | Small Fragment Dynamic Compression Locking (DCL) System | Synthes (Usa) | 2000 | 1 |
| −2 | K011335 | Synths One-Third Tubular DCL Plate | Synthes (Usa) | 2001 | 2 |
| −1 | K093761 | Optilock VL (Variable Angle Locking) Distal Radius Plating System | Biomet Trauma (Aka Ebi, Lp) | 2010 | — |
| 0 (this device) | K150675 | Dorsal Spanning Plate | Skeletal Dynamics, LLC | 2015 | — |
| +1 | K212601 | DRPx Locking Distal Radius Plate System | Orthopaedic Implant Company | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 2 | 0 |
| 2001 | 1 | 0 |
| 2002 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 2 | 0 |
| 2006 | 2 | 0 |
| 2007 | 1 | 0 |
| 2009 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K093761 | Optilock VL (Variable Angle Locking) Distal Radius Plating SystemSummary page 4…accessories Classification 21 CFR §888.3030 Product Code HRS Class Class II Predicate Devices: OptiLock VL Distal Radius Plating System (K093761) Description of the Device: The Skeletal Dynamics Dorsal Spanning Plate consists of a bone plate designed for fracture fixation… | 2010 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K212601 | DRPx Locking Distal Radius Plate System | 2022 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 5.2 years on median.
- 6 of the 16 ancestors have a recall of any class.
- Of its descendants, K212601 (Orthopaedic Implant Company, 2022) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K093761.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The Skeletal Dynamics Dorsal Spanning Plate is intended for
fixation of fractures involving the distal radius and for wrist arthrodesis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K150675 · printed Nov 4, 2026
Cite this page
510(k) Report. “K150675: Dorsal Spanning Plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K150675
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026