510(k) Report

510(k) · Cleared

Cleared

AXIOS Stent with Electrocautery Enhanced Delivery System

K150692510(k) TraditionalCleared Aug 5, 2015140-day reviewClass II21 CFR 876.5015

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corp · PCU Pancreatic Stent, Covered, Metallic, Removable

Cleared on Aug 5, 2015 as substantially equivalent to K140561 (Xlumena, Inc., 2014) and 2 other predicates after a 140-day review. Its family tree reaches back 3 generations to 1997. 8 later devices descend from it.

Decided
Aug 5, 2015
Review
140 days
Class
Class II
Product code
PCU
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K970053 (1997). 7 ancestors in all. 8 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2013: 1 other ancestor1997: 2 other ancestors2015: 2 descendants cleared2017: 1 descendant cleared2019: 2 descendants cleared2022: 1 descendant cleared2021: 1 descendant cleared2026: 1 descendant clearedK970053 · Ultratomerx · Boston Scientific Corp · 1997K013153 · Autotome RX Model # 4515, 4516 · Boston Scientific Corp · 2001 · recalledK022595 · Wilson-Cook Cystotome · Wilson-Cook Medical, Inc. · 20021995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 3 descendants4 generations forward: 1 descendant K022595 · Wilson-Cook Cystotome · Wilson-Cook Medical, Inc. · 2002K013153 · Autotome RX Model # 4515, 4516 · Boston Scientific Corp · 2001 · recalledK970053 · Ultratomerx · Boston Scientific Corp · 19970
  1. Root · 3 generations backK970053 UltratomerxBoston Scientific Corp · 1997
  2. 2 generations backK013153 Autotome RX Model # 4515, 4516Boston Scientific Corp · 2001 · Recalled
  3. 1 generation backK022595 Wilson-Cook CystotomeWilson-Cook Medical, Inc. · 2002
  4. This deviceK150692 AXIOS Stent with Electrocautery Enhanced Delivery SystemBoston Scientific Corp · 2015
  5. Descendant · cites it directly · 7 of its ownK152572 AXIOS Stent and Delivery SystemBoston Scientific Corporation · 2015
  6. Descendant · cites it directly · 6 of its ownK153088 AXIOS Stent with Delivery System, AXIOS Stent with Electro-cautery…Boston Scientific Corporation · 2015
  7. Descendant · 2 generations on · 5 of its ownK163272 AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation · 2017
  8. Descendant · 2 generations on · 4 of its ownK181905 AXIOS Stent and Delivery System, AXIOS Stent and Electrocautery…Boston Scientific Corporation · 2019 · Recalled
  9. Descendant · 3 generations on · 2 of its ownK192043 AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation · 2019

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2015: 22017: 12019: 22021: 12022: 12026: 1
2015high 2 (2015) · low 0 (2016)2026

Most influential descendants

Showing 5 of 8 · See all
  • K152572AXIOS Stent and Delivery SystemBoston Scientific Corporation · 2015 · cites it directly7descendants
  • K153088AXIOS Stent with Delivery System, AXIOS Stent with Electro-cautery Enhanced Delivery…Boston Scientific Corporation · 2015 · cites it directly6descendants
  • K163272AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation · 2017 · 2 generations on5descendants
  • K181905AXIOS Stent and Delivery System, AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation · 2019 · 2 generations on4descendants
  • K192043AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation · 2019 · 3 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K970053UltratomerxBoston Scientific Corp1997—
−2K013153Autotome RX Model # 4515, 4516Boston Scientific Corp200132
−1K022595Wilson-Cook CystotomeWilson-Cook Medical, Inc.2002—
0 (this device)K150692AXIOS Stent with Electrocautery Enhanced Delivery SystemBoston Scientific Corp2015—
+1K152572AXIOS Stent and Delivery SystemBoston Scientific Corporation2015—
+1K153088AXIOS Stent with Delivery System, AXIOS Stent with Electro-cautery Enhanced…Boston Scientific Corporation2015—
+2K163272AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation2017—
+2K181905AXIOS Stent and Delivery System, AXIOS Stent and Electrocautery Enhanced…Boston Scientific Corporation20198
+3K192043AXIOS Stent and Electrocautery Enhanced Delivery SystemBoston Scientific Corporation2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199720
201310
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201520
201710
201920
202110
202210
202610
FIG. 1 — Lineage of K150692, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PCU? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PCU device

  1. #1 K252648 Niti-S SPAXUS Stentscore 13.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140561Axios Stent and Delivery System (with 10MM X 10MM Stent) Axios Stent and Delivery System…
Summary page 4
…1 CFR 876.4300 Product Code: PCU / 78KNS Predicate Devices (Legally Xlumena, Inc. AXIOS Stent and Delivery System marketed devices to which K140561 and K123250 substantial equivalence is Wilson-Cook Medical, Inc. Wilson-Cook Cystotome claimed):…
Xlumena, Inc.2014—
*DEN130007Axios Stent and Delivery System
Our reading of the summary gave K123250, which is not in FDA’s 510(k) list. The device the summary names is FDA’s De Novo DEN130007, Axios Stent and Delivery System (Xlumena, Inc.), granted Dec 18, 2013; older De Novo requests were first filed under a 510(k) number, so this links to the grant.
Xlumena, Inc.2013—
*K022595Wilson-Cook Cystotome
Summary page 4
…eted devices to which K140561 and K123250 substantial equivalence is Wilson-Cook Medical, Inc. Wilson-Cook Cystotome claimed): K022595 I. Device Description: The AXIOS Stent with Electrocautery Enhanced Delivery System is intended for the endoscopic placement of…
Wilson-Cook Medical, Inc.2002—

Also cleared against K140561: 1 other device →

What descends from it? (8)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152572AXIOS Stent and Delivery SystemBoston Scientific Corporation20157
K153088AXIOS Stent with Delivery System, AXIOS Stent with Electro-cautery Enhanced Delivery…Boston Scientific Corporation20156

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 4.6 years on median.
  • 1 of the 7 ancestors has a recall of any class.
  • Of its descendants, K152572 (Boston Scientific Corporation, 2015) has gone furthest, with 7 descendants of its own.
  • 1 other device also cites its predicate K140561.

How does its category compare?

All PCU devices

PCU Pancreatic Stent, Covered, Metallic, Removable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · PCU

1in 2022

2013: 12014: 12015: 32017: 12019: 22021: 12022: 12026 (partial year): 1
2007high 3 (2015) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PCU

46in 2015

2015: 46 days median
2007high 46 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PCU

6in 2020

2020: 6
2007high 6 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PCU

292in 2025

2014: 32015: 172016: 1012017: 952018: 902019: 1362020: 1442021: 1622022: 2082023: 2602024: 4162025: 292
2007high 416 (2024) · low 0 (2007)2025

MAUDE reports naming product code PCU, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20131—00
20141—03
2015346017
20160—0101
20171—095
20180—090
20192—0136
20200—6144
20211—0162
20221—0208
20230—0260
20240—0416
20250—0292
20261—0—

What is it indicated for?

The AXIOS Stent with Electrocautery Enhanced Delivery System is indicated for use to facilitate transgastric or transduodenal endoscopic drainage of symptomatic pancreatic pseudocysts = 6cm in size, with > 70% fluid content that are adherent to the gastric or bowel wall. Once placed, the AXIOS Stent functions as an access port allowing passage of standard and therapeutic endoscopes to facilitate debridement, irrigation and cystoscopy. The stent is intended for implantation up to 60 days and should be removed upon confirmation of pseudocyst resolution.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K150692: AXIOS Stent with Electrocautery Enhanced Delivery System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150692

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026