CapsoCam (SV-1)

K151635510(k) TraditionalCleared Feb 9, 2016237-day reviewClass II21 CFR 876.1300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

CapsoVision, Inc. · NEZ System, Imaging, Gastrointestinal, Wireless, Capsule

Cleared on Feb 9, 2016 as substantially equivalent to K070475 (Given Imaging, Ltd., 2007) after a 237-day review. Its family tree reaches back 13 generations to 2001. 1 later device descends from it.

Decided
Feb 9, 2016
Review
237 days
Class
Class II
Product code
NEZ
Recalls
None
Predicates
1

Its longest line of descent runs back 13 generations to DEN010002 (2001). 1 later device descends from it, 1 citing it directly.

  1. Root · 13 generations backDEN010002 Given Diagnostic Imaging SystemGiven Imaging, Ltd. · 2001
  2. 9 generations between
  3. 3 generations backK060805 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2006
  4. 2 generations backK062786 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2006
  5. 1 generation backK070475 Modificaton to: Given Diagnostic Imaging SystemGiven Imaging, Ltd. · 2007
  6. This deviceK151635 CapsoCam (SV-1)CapsoVision, Inc. · 2016
  7. Descendant · cites it directly · 0 of its ownK161773 CapsoCam Plus (SV-3) Capsule Endoscope SystemCapsoVision, Inc. · 2016
Show all 13 generations
  1. Root · 13 generations backDEN010002 Given Diagnostic Imaging SystemGiven Imaging, Ltd. · 2001
  2. 12 generations backK020341 Given Diagnostic SystemGiven Imaging, Ltd. · 2002
  3. 11 generations backK022362 Given Diagnostics SystemGiven Imaging, Ltd. · 2002
  4. 10 generations backK022980 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2003
  5. 9 generations backK031033 Given Diagnostic SystemGiven Imaging, Ltd. · 2003
  6. 8 generations backK032405 Given Diagnostic SystemGiven Imaging, Ltd. · 2003
  7. 7 generations backK040248 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2004
  8. 6 generations backK041149 Given Diagnostic System with M2A Eso CapsuleGiven Imaging, Ltd. · 2004
  9. 5 generations backK042960 Given Diagnostic System with Pillcam EsoGiven Imaging, Ltd. · 2004
  10. 4 generations backK052184 Given Diagnostic SystemGiven Imaging, Ltd. · 2005
  11. 3 generations backK060805 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2006
  12. 2 generations backK062786 Modification to Given Diagnostic SystemGiven Imaging, Ltd. · 2006
  13. 1 generation backK070475 Modificaton to: Given Diagnostic Imaging SystemGiven Imaging, Ltd. · 2007
  14. This deviceK151635 CapsoCam (SV-1)CapsoVision, Inc. · 2016

Most influential descendants

Showing 1 of 1 · See all
  • K161773CapsoCam Plus (SV-3) Capsule Endoscope SystemCapsoVision, Inc. · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13DEN010002Given Diagnostic Imaging SystemGiven Imaging, Ltd.2001—
−12K020341Given Diagnostic SystemGiven Imaging, Ltd.2002—
−11K022362Given Diagnostics SystemGiven Imaging, Ltd.2002—
−10K022980Modification to Given Diagnostic SystemGiven Imaging, Ltd.2003—
−9K031033Given Diagnostic SystemGiven Imaging, Ltd.2003—
−8K032405Given Diagnostic SystemGiven Imaging, Ltd.2003—
−7K040248Modification to Given Diagnostic SystemGiven Imaging, Ltd.2004—
−6K041149Given Diagnostic System with M2A Eso CapsuleGiven Imaging, Ltd.2004—
−5K042960Given Diagnostic System with Pillcam EsoGiven Imaging, Ltd.2004—
−4K052184Given Diagnostic SystemGiven Imaging, Ltd.2005—
−3K060805Modification to Given Diagnostic SystemGiven Imaging, Ltd.2006—
−2K062786Modification to Given Diagnostic SystemGiven Imaging, Ltd.2006—
−1K070475Modificaton to: Given Diagnostic Imaging SystemGiven Imaging, Ltd.2007—
0 (this device)K151635CapsoCam (SV-1)CapsoVision, Inc.2016—
+1K161773CapsoCam Plus (SV-3) Capsule Endoscope SystemCapsoVision, Inc.2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K151635, 2001–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NEZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NEZ device

  1. #1 K252617 MiroCam® Capsule Endoscope Systemscore 17.0 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070475Modificaton to: Given Diagnostic Imaging System
Summary page 4
…etric gastrointestinal capsule imaging system (21 CFR § 876.1300) Predicate Devices: Given Imaging PillCam™ SB2 (K070475) Intended Use: The CapsoCam video capsule system is intended for visualization of the small bowel mucosa in adul…
Given Imaging, Ltd.2007—

Also cleared against K070475: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161773CapsoCam Plus (SV-3) Capsule Endoscope SystemCapsoVision, Inc.20160

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 2 companies; a new generation was cleared every 6 months on median.
  • None of the 13 ancestors has a recall.
  • Of its descendants, K161773 (CapsoVision, Inc., 2016) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K070475.

How does its category compare?

All NEZ devices

NEZ System, Imaging, Gastrointestinal, Wireless, Capsule: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · NEZ

1in 2025

2007: 22009: 22010: 12011: 32012: 12013: 32014: 32015: 22016: 22017: 42018: 32019: 22020: 12021: 12022: 12023: 12024: 32025: 12026 (partial year): 1
2007high 4 (2017) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NEZ

99in 2024

2011: 213 days median2013: 194 days median2014: 194 days median2017: 83 days median2018: 233 days median2024: 99 days median
2007high 233 (2018) · low 83 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NEZ

1in 2011

2007: 12011: 1
2007high 1 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NEZ

69in 2025

2008: 92009: 62010: 132011: 102012: 192013: 62014: 132015: 302016: 572017: 552018: 502019: 562020: 312021: 412022: 632023: 342024: 1032025: 69
2007high 103 (2024) · low 0 (2007)2025

MAUDE reports naming product code NEZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—10
20080—09
20092—06
20101—013
20113213110
20121—019
2013319406
20143194013
20152—030
20162—057
2017483055
20183233050
20192—056
20201—031
20211—041
20221—063
20231—034
20243990103
20251—069
20261—0—

What is it indicated for?

The CapsoCam SV-1 video capsule system is intended for visualization of the small bowel mucosa in adults. It may be used as a tool in the detection of abnormalities of the small bowel.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K151635: CapsoCam (SV-1).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K151635

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026