510(k) Report

510(k) · Cleared

Recalled · Class I · 2018

Reprocessed Steerable Introducer

K152090510(k) TraditionalCleared Mar 23, 2016240-day reviewClass II21 CFR 870.1340Recalls 2 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sterilmed, Inc. · PNE Reprocessed Catheter Introducer

Cleared on Mar 23, 2016 as substantially equivalent to K061363 (St Jude Medical, 2006) and 1 other predicate after a 240-day review. Its family tree reaches back 4 generations to 1997. 1 of the 7 devices in its family, counting itself, has a Class I recall. It has been recalled 2 times, including a Class I recall.

Decided
Mar 23, 2016
Review
240 days
Class
Class II
Product code
PNE
Recalls
2 (1 Class I)
Predicates
2

Its longest line of descent runs back 4 generations to K964518 (1997). 6 ancestors in all. No later device cites it as a predicate yet. 1 of the 7 devices in this family, counting this one, has a Class I recall.

  1. Root · 4 generations backK964518 Fast-Cath Transseptal Catheter IntroducerDaig Corp. · 1997 · Recalled
  2. 3 generations backK042623 Agilis Steerable Catheter Introducer, Model 408304St. Jude Medical, Daig Division, Inc. · 2005 · Recalled
  3. 2 generations backK061363 Agilis NXT Steerable IntroducerSt Jude Medical · 2006 · Recalled
  4. 1 generation backK081645 Agilis NXT Steerable Introducer, Model G408324St Jude Medical · 2008
  5. This deviceK152090 Reprocessed Steerable IntroducerSterilmed, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K964518Fast-Cath Transseptal Catheter IntroducerDaig Corp.19974
−3K042623Agilis Steerable Catheter Introducer, Model 408304St. Jude Medical, Daig Division, Inc.20051
−2K061363Agilis NXT Steerable IntroducerSt Jude Medical20061
−1K081645Agilis NXT Steerable Introducer, Model G408324St Jude Medical2008—
0 (this device)K152090Reprocessed Steerable IntroducerSterilmed, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200210
FIG. 1 — Lineage of K152090, 1997–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PNE device

  1. #1 K250305 Reprocessed Agilis NxT Steerable Introducerscore 14.8 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061363Agilis NXT Steerable Introducer
Summary page 6
…oroscopy. 1.6 PERFORMANCE TESTING OVERVIEW The reprocessed steerable introducer devices are substantially equivalent to the new un- reprocessed predicate devices (K061363 and K081645) in that the reprocessed devices are the same as the new un-reprocessed predicate devices in terms of form, fit, func…
St Jude Medical20061
*K081645Agilis NXT Steerable Introducer, Model G408324
Summary page 6
….6 PERFORMANCE TESTING OVERVIEW The reprocessed steerable introducer devices are substantially equivalent to the new un- reprocessed predicate devices (K061363 and K081645) in that the reprocessed devices are the same as the new un-reprocessed predicate devices in terms of form, fit, function, and in…
St Jude Medical2008—
†K935170Cardiovascular and Vascular Guidewire ModificationsLake Region Mfg., Inc.1994—

Also cleared against K061363: 14 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 17, 2018Class IIZ-0090-2019Material/Component ContaminationReprocessed Agilis Steerable Introducers may not meet endotoxin requirements per product specification for biological residues determined by LAL testing.
Jun 2, 2017Class IZ-0213-2018Process controlInadequate seal due to lack of adhesive glue

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 7.3 years on median.
  • 4 of the 6 ancestors have a recall of any class.
  • 14 other devices also cite its predicate K061363.

How does its category compare?

All PNE devices

PNE Reprocessed Catheter Introducer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · PNE

1in 2025

2016: 12017: 12022: 12023: 12024: 12025: 12026 (partial year): 1
2007high 1 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PNE

Too few PNE 510(k)s in any year since 2007 to give a median.

Recalls per year · PNE

No recall names PNE since 2007.

Adverse event reports per year · PNE

4in 2024

2017: 22021: 12022: 22023: 52024: 4
2007high 5 (2023) · low 0 (2007)2025

MAUDE reports naming product code PNE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—00
20171—02
20180—00
20190—00
20200—00
20210—01
20221—02
20231—05
20241—04
20251—00
20261—0—

What is it indicated for?

The reprocessed steerable introducer devices are indicated for introducing various cardiovascular catheters into the heart, including the left side of the heart through the interatrial septum.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K152090: Reprocessed Steerable Introducer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152090

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026