510(k) · Cleared
ClearedNITRILE BLUE POWDER FREE EXAMINATION GLOVES tested for use with Chemotheraphy Drugs
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Gmp Medicare Sdn Bhd (F25) · LZC Medical Glove, Specialty
Cleared on Apr 21, 2016 after a 258-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Apr 21, 2016
- Review
- 258 days
- Class
- Class I
- Product code
- LZC
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LZC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LZC device
- #1 K201390 Medline Powder-Free Light Blue Nitrile Exam…score 19.2 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LZC devicesLZC Medical Glove, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · LZC
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LZC
85in 2022
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LZC
1in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LZC
10in 2025
MAUDE reports naming product code LZC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 3 | 166 | 1 | 0 |
| 2009 | 5 | 253 | 0 | 1 |
| 2010 | 5 | 68 | 0 | 0 |
| 2011 | 0 | — | 4 | 1 |
| 2012 | 4 | 149 | 0 | 1 |
| 2013 | 0 | — | 0 | 1 |
| 2014 | 0 | — | 0 | 3 |
| 2015 | 1 | — | 0 | 0 |
| 2016 | 3 | 258 | 0 | 5 |
| 2017 | 6 | 121 | 0 | 7 |
| 2018 | 6 | 105 | 0 | 6 |
| 2019 | 7 | 200 | 0 | 8 |
| 2020 | 3 | 167 | 0 | 1 |
| 2021 | 3 | 94 | 1 | 2 |
| 2022 | 7 | 85 | 0 | 2 |
| 2023 | 0 | — | 0 | 1 |
| 2024 | 0 | — | 0 | 16 |
| 2025 | 1 | — | 0 | 10 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
An Examination Glove is a disposable device intended for medical purpose that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. These gloves were tested for use with Chemotherapy Drugs as per ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs: Chemotherapy Drug Permeation The following chemicals have been tested with these gloves Chemotherapy Drug…
Read the full statement (140 words)
An Examination Glove is a disposable device intended for medical purpose that is worn on the examiner's hand or finger
to prevent contamination between patient and examiner.
These gloves were tested for use with Chemotherapy Drugs as per ASTM D6978-05 Standard Practice for Assessment of
Medical Gloves to Permeation by Chemotherapy Drugs:
Chemotherapy Drug Permeation
The following chemicals have been tested with these gloves
Chemotherapy Drug Concentration Breakthrough Detection Time in Minutes
Carmustine (BCNU) 3.3mg/ml *10.1
Cisplatin 1.0mg/ml >240
Cyclophosphamide (Cytoxan) 20.0mg/ml >240
Dacarbazine {DTIC) 10.0mg/ml >240
Doxorubicin Hydrochloride 2.0mg/ml >240
Etoposide (Toposar) 20.0mg/ml >240
Fluorouracil 50.0mg/ml >240
Paclitaxel (Taxol) 6.0mg/ml >240
Thiotepa 10.0mg/ml *20.2
Amethopterin Hydrate 25.0mg/ml >240
Methotrexate 25.0mg/ml >240
Mitomycin C 0.5mg/ml >240
Vincristine Sulfate 1.0mg/ml >240
* Please note that the following drugs have extremely low permeation times:
Carmustine (BCNU): 10.1 minutes and Thiotepa: 20.2 minutes
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K152222 · printed Nov 5, 2026
Cite this page
510(k) Report. “K152222: NITRILE BLUE POWDER FREE EXAMINATION GLOVES tested for use with Chemotheraphy Drugs.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K152222
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026