510(k) Report

510(k) · Cleared

Cleared

Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 Guidewire

K152231510(k) TraditionalCleared Feb 12, 2016189-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corporation · DQX Wire, Guide, Catheter

Cleared on Feb 12, 2016 as substantially equivalent to K143587 (Boston Scientific Corporation, 2015) after a 189-day review. Its family tree reaches back 5 generations to 1991. 2 later devices descend from it.

Decided
Feb 12, 2016
Review
189 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K913353 (1991). 21 ancestors in all. 2 later devices descend from it, 2 citing it directly.

  1. Root · 5 generations backK913353 Vascular Guide WireAdvanced Cardiovascular Systems, Inc. · 1991
  2. 4 generations backK971815 Asc Balance Middleweight Guide WireGuidant Corp. · 1997
  3. 3 generations backK973494 HI-Torque Balance Guide Wire with Hydrocoat Hydrophilic Coating, Acs…Guidant Corp. · 1997
  4. 2 generations backK030617 PT2 Guide Wire and Addwire Extension WireBoston Scientific Scimed, Inc. · 2003 · Recalled
  5. 1 generation backK143587 ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT…Boston Scientific Corporation · 2015 · Recalled
  6. This deviceK152231 Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 GuidewireBoston Scientific Corporation · 2016
  7. Descendant · cites it directly · 0 of its ownK193194 CrossTorq 14 GuidewireScientia Cardio Access, LLC · 2019
  8. Descendant · cites it directly · 0 of its ownK180795 JUDO 1 Guidewire, JUDO 3 Guidewire, JUDO 6 GuidewireBoston Scientific · 2018

Most influential descendants

Showing 2 of 2 · See all
  • K193194CrossTorq 14 GuidewireScientia Cardio Access, LLC · 2019 · cites it directly0descendants
  • K180795JUDO 1 Guidewire, JUDO 3 Guidewire, JUDO 6 GuidewireBoston Scientific · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K913353Vascular Guide WireAdvanced Cardiovascular Systems, Inc.1991—
−4K971815Asc Balance Middleweight Guide WireGuidant Corp.1997—
−3K973494HI-Torque Balance Guide Wire with Hydrocoat Hydrophilic Coating, Acs HI-Torque…Guidant Corp.1997—
−2K030617PT2 Guide Wire and Addwire Extension WireBoston Scientific Scimed, Inc.20034
−1K143587ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT Guide Wire…Boston Scientific Corporation20151
0 (this device)K152231Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 GuidewireBoston Scientific Corporation2016—
+1K193194CrossTorq 14 GuidewireScientia Cardio Access, LLC2019—
+1K180795JUDO 1 Guidewire, JUDO 3 Guidewire, JUDO 6 GuidewireBoston Scientific2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199420
199550
199640
199710
199810
200110
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
FIG. 1 — Lineage of K152231, 1991–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143587ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT Guide Wire, PT Graphix…
Summary page 4
…rt 870.1330 Primary Predicate 15 Jan 2015 ChoICE™ Guidewire K143587 Device Reference ASAHI Confianza Pro 08 Mar 2013 Device(s)…
Boston Scientific Corporation20151
†K041531Asahi Ptca Guide Wire Confianza ProAsahi Intecc Co., Ltd.2004—

Also cleared against K143587: 3 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K193194CrossTorq 14 GuidewireScientia Cardio Access, LLC20190
K180795JUDO 1 Guidewire, JUDO 3 Guidewire, JUDO 6 GuidewireBoston Scientific20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 5.4 years on median.
  • 5 of the 21 ancestors have a recall of any class.
  • Of its descendants, K193194 (Scientia Cardio Access, LLC, 2019) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K143587.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

Boston Scientific Hornet, Hornet 10, and Hornet 14 Guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (PTCA) or other intravascular interventional procedures. These guidewires are not intended for use in the cerebral vasculature.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K152231: Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 Guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152231

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026