510(k) · Cleared
ClearedViZion DR + Wireless
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Viztek, LLC · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)
Cleared on Sep 10, 2015 as substantially equivalent to K123644 (Viztek, LLC, 2013) after a 29-day review. Its family tree reaches back 9 generations to 1998. 27 later devices descend from it.
- Decided
- Sep 10, 2015
- Review
- 29 days
- Class
- Class II
- Product code
- MQB
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K981556 (1998). 20 ancestors in all. 27 later devices descend from it, 2 citing it directly.
- Root · 9 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
- 5 generations between
- 3 generations backK102123 Vizion DRViztek, Inc. · 2011
- 2 generations backK112661 Vizion DRViztek, LLC · 2011
- 1 generation backK123644 Vizion + DRViztek, LLC · 2013
- This deviceK152279 ViZion DR + WirelessViztek, LLC · 2015
- Descendant · cites it directly · 24 of its ownK161730 Wireless Digital Flat Panel DetectorIray Technology (Shanghai), Ltd. · 2016
- Descendant · 2 generations on · 18 of its ownK182551 Wireless Digital Flat Panel DetectorIray Technology Taicang, Ltd. · 2018
- Descendant · 3 generations on · 9 of its ownK183713 Wireless Digital Flat DetectorIray Technology Taicang, Ltd. · 2019
- Descendant · 4 generations on · 7 of its ownK201043 Wireless Digital Flat Panel Detector (Model: Mars1717V-VSI, Mano4343W)Iray Technology Taicang, Ltd. · 2020
- Descendant · 5 generations on · 4 of its ownK210314 Mars1717X Wireless Digital Flat Panel DetectorIray Technology Taicang, Ltd. · 2021
Show all 9 generations
- Root · 9 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
- 8 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
- 7 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
- 6 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
- 5 generations backK042876 Urs LP Digital, Millennium, RadproSedecal., Sa. · 2004
- 4 generations backK082604 Viztek DR, Models: DR1000, DR3000, DR4000Viztek, Inc. · 2008
- 3 generations backK102123 Vizion DRViztek, Inc. · 2011
- 2 generations backK112661 Vizion DRViztek, LLC · 2011
- 1 generation backK123644 Vizion + DRViztek, LLC · 2013
- This deviceK152279 ViZion DR + WirelessViztek, LLC · 2015
Showing 5 of 27 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 27 · See all- K161730Wireless Digital Flat Panel DetectorIray Technology (Shanghai), Ltd. · 2016 · cites it directly24descendants
- K182551Wireless Digital Flat Panel DetectorIray Technology Taicang, Ltd. · 2018 · 2 generations on18descendants
- K183713Wireless Digital Flat DetectorIray Technology Taicang, Ltd. · 2019 · 3 generations on9descendants
- K201043Wireless Digital Flat Panel Detector (Model: Mars1717V-VSI, Mano4343W)Iray Technology Taicang, Ltd. · 2020 · 4 generations on7descendants
- K210314Mars1717X Wireless Digital Flat Panel DetectorIray Technology Taicang, Ltd. · 2021 · 5 generations on4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K981556 | Canon X-Ray Digital Camera Cxdi-11 | Canon USA, Inc. | 1998 | — |
| −8 | K992547 | Canon X-Ray Digital Camera, Model Cxdi-22 | Canon USA, Inc. | 1999 | — |
| −7 | K023750 | Cannon Digital Radiography Model Cxdi-40G | Canon USA, Inc. | 2002 | — |
| −6 | K031447 | Canon, Digital Radiography, Model Cxdi-50G | Canon, Inc. | 2003 | — |
| −5 | K042876 | Urs LP Digital, Millennium, Radpro | Sedecal., Sa. | 2004 | — |
| −4 | K082604 | Viztek DR, Models: DR1000, DR3000, DR4000 | Viztek, Inc. | 2008 | — |
| −3 | K102123 | Vizion DR | Viztek, Inc. | 2011 | — |
| −2 | K112661 | Vizion DR | Viztek, LLC | 2011 | — |
| −1 | K123644 | Vizion + DR | Viztek, LLC | 2013 | — |
| 0 (this device) | K152279 | ViZion DR + Wireless | Viztek, LLC | 2015 | — |
| +1 | K161730 | Wireless Digital Flat Panel Detector | Iray Technology (Shanghai), Ltd. | 2016 | — |
| +2 | K182551 | Wireless Digital Flat Panel Detector | Iray Technology Taicang, Ltd. | 2018 | — |
| +3 | K183713 | Wireless Digital Flat Detector | Iray Technology Taicang, Ltd. | 2019 | — |
| +4 | K201043 | Wireless Digital Flat Panel Detector (Model: Mars1717V-VSI, Mano4343W) | Iray Technology Taicang, Ltd. | 2020 | — |
| +5 | K210314 | Mars1717X Wireless Digital Flat Panel Detector | Iray Technology Taicang, Ltd. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
| 2001 | 4 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2012 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 6 | 0 |
| 2020 | 3 | 0 |
| 2021 | 4 | 0 |
| 2022 | 6 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQB device
- #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K123644 | Vizion + DRSummary page 4…Common/Usual Name: Digital X-Ray Receptor Panel Device Class/Regulation Number: Class II per regulation 892.1680 2. Equivalent legally marketed device: ViZion DR +, K123644, Viztek. Classification Name: Stationary X-Ray System Product Code: MQB, Common/Usual Name: Digital X-Ray Receptor Panel… | 2013 |
What descends from it? (27)
See all 272 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 5 companies; a new generation was cleared every 1.5 years on median.
- 1 of the 20 ancestors has a recall of any class.
- Of its descendants, K161730 (Iray Technology (Shanghai), Ltd., 2016) has gone furthest, with 24 descendants of its own.
- 3 other devices also cite its predicate K123644.
How does its category compare?
All MQB devicesMQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · MQB
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MQB
127in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQB
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQB
141in 2025
MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 22 | 15 | 25 |
| 2008 | 8 | 15 | 36 | 30 |
| 2009 | 15 | 57 | 19 | 34 |
| 2010 | 11 | 116 | 14 | 39 |
| 2011 | 24 | 102 | 10 | 101 |
| 2012 | 22 | 80 | 8 | 267 |
| 2013 | 21 | 105 | 6 | 159 |
| 2014 | 32 | 102 | 0 | 29 |
| 2015 | 21 | 81 | 0 | 21 |
| 2016 | 22 | 92 | 0 | 26 |
| 2017 | 31 | 30 | 1 | 20 |
| 2018 | 16 | 30 | 4 | 84 |
| 2019 | 22 | 30 | 1 | 45 |
| 2020 | 19 | 28 | 4 | 9 |
| 2021 | 21 | 48 | 1 | 26 |
| 2022 | 31 | 48 | 0 | 13 |
| 2023 | 10 | 30 | 0 | 51 |
| 2024 | 8 | 187 | 0 | 91 |
| 2025 | 8 | 127 | 1 | 141 |
| 2026 | 3 | 245 | 1 | — |
What is it indicated for?
Intended for digital image capture use in general radiographic examinations, wherever conventional screen-film systems may be used, excluding fluoroscopy, angiography and mammography. ViZion DR + Wireless allows imaging of the skull, chest, shoulders, spine, abdomen, pelvis, and extremities..
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K152279 · printed Nov 5, 2026
Cite this page
510(k) Report. “K152279: ViZion DR + Wireless.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K152279
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026