510(k) Report

510(k) · Cleared

Cleared

RiverLon (Nylon) Suture

K152795510(k) SpecialCleared Oct 28, 201530-day reviewClass II21 CFR 878.5020

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Riverpoint Medical · GAR Suture, Nonabsorbable, Synthetic, Polyamide

Cleared on Oct 28, 2015 as substantially equivalent to K100006 (Riverpoint Medical, 2010) after a 30-day review. Its family tree reaches back 5 generations to 1999.

Decided
Oct 28, 2015
Review
30 days
Class
Class II
Product code
GAR
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K990088 (1999). 20 ancestors in all, the oldest K930590 (1993). No later device cites it as a predicate yet.

  1. Root · 5 generations backK990088 Synthofil Nonabsorbable Pet Surgical SutureAesculap, Inc. · 1999
  2. 4 generations backK012923 Arthrex Fiberwire, Usp Size 5, Model AR-7201Arthrex, Inc. · 2001
  3. 3 generations backK021434 Arthrex Fiberwire in Usp SizesArthrex, Inc. · 2002
  4. 2 generations backK063778 Force Fiber Polyethylene Nonabsorbable SutureTeleflex Medical · 2007 · Recalled
  5. 1 generation backK100006 HS Fiber (Polyblend), River Bond, Riversilk (Silk), Riverpro…Riverpoint Medical · 2010 · Recalled
  6. This deviceK152795 RiverLon (Nylon) SutureRiverpoint Medical · 2015
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K990088Synthofil Nonabsorbable Pet Surgical SutureAesculap, Inc.1999—
−4K012923Arthrex Fiberwire, Usp Size 5, Model AR-7201Arthrex, Inc.2001—
−3K021434Arthrex Fiberwire in Usp SizesArthrex, Inc.2002—
−2K063778Force Fiber Polyethylene Nonabsorbable SutureTeleflex Medical20071
−1K100006HS Fiber (Polyblend), River Bond, Riversilk (Silk), Riverpro (Polypropylene)…Riverpoint Medical20102
0 (this device)K152795RiverLon (Nylon) SutureRiverpoint Medical2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199410
199610
199910
200040
200130
200210
200420
200510
FIG. 1 — Lineage of K152795, 1999–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GAR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GAR device

  1. #1 K261484 Tissue Approximation Systemscore 11.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100006HS Fiber (Polyblend), River Bond, Riversilk (Silk), Riverpro (Polypropylene), Riverlon…
Summary page 4
…nstructive Surgery Devices Branch Two - Skin/Wound Dressing/Aesthetic Injectables Predicate Device K100006 – Riverpoint Medical RiverLon (Nylon) -25-…
Riverpoint Medical20102

Also cleared against K100006: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 3.2 years on median.
  • 9 of the 20 ancestors have a recall of any class.
  • 8 other devices also cite its predicate K100006.

How does its category compare?

All GAR devices

GAR Suture, Nonabsorbable, Synthetic, Polyamide: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · GAR

1in 2023

2008: 12013: 12015: 12016: 12017: 12020: 12021: 12022: 12023: 12026 (partial year): 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GAR

Too few GAR 510(k)s in any year since 2007 to give a median.

Recalls per year · GAR

1in 2023

2008: 12011: 12023: 12026 (partial year): 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GAR

823in 2025

2007: 182008: 142009: 122010: 392011: 82012: 52013: 422014: 1032015: 862016: 1242017: 1802018: 5412019: 5182020: 3842021: 5322022: 5492023: 6072024: 6682025: 823
2007high 823 (2025) · low 5 (2012)2025

MAUDE reports naming product code GAR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—018
20081—114
20090—012
20100—039
20110—18
20120—05
20131—042
20140—0103
20151—086
20161—0124
20171—0180
20180—0541
20190—0518
20201—0384
20211—0532
20221—0549
20231—1607
20240—0668
20250—0823
20261—1—

What is it indicated for?

RiverLon Suture is intended to be used in general soft tissue approximation and/or ligation,

including use in cardiovascular, ophthalmic, and neurological procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K152795: RiverLon (Nylon) Suture.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152795

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026