Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, Camera Sterilization Tray

K152951510(k) TraditionalCleared Dec 28, 201583-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Paragon Medical, Inc. · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories

Cleared on Dec 28, 2015 as substantially equivalent to K141616 (Oticon Medical AB, 2014) after an 83-day review. Its family tree reaches back 5 generations to 1984. 1 later device descends from it.

Decided
Dec 28, 2015
Review
83 days
Class
Class II
Product code
KCT
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K844002 (1984). 7 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 5 generations backK844002 HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc. · 1984
  2. 4 generations backK980065 C/T Med-Systems Cassette SystemC/T Med System, Ltd. · 1998
  3. 3 generations backK990761 Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd. · 1999
  4. 2 generations backK012105 Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc. · 2002
  5. 1 generation backK141616 Sterilization CassetteOticon Medical AB · 2014
  6. This deviceK152951 Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and…Paragon Medical, Inc. · 2015
  7. Descendant · cites it directly · 0 of its ownK190667 Sonopet iQ Sterilization TrayParagon Medical · 2019

Most influential descendants

Showing 1 of 1 · See all
  • K190667Sonopet iQ Sterilization TrayParagon Medical · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K844002HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc.1984—
−4K980065C/T Med-Systems Cassette SystemC/T Med System, Ltd.1998—
−3K990761Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd.1999—
−2K012105Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc.2002—
−1K141616Sterilization CassetteOticon Medical AB2014—
0 (this device)K152951Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera…Paragon Medical, Inc.2015—
+1K190667Sonopet iQ Sterilization TrayParagon Medical2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K152951, 1984–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KCT device

  1. #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141616Sterilization Cassette
Summary page 5
…ners, trays, cassettes and other accessories, Class II Product Code KCT Predicate Device Sterilization cassette by Oticon Medical AB, k141616 Device Description: The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera…
Oticon Medical AB2014—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K190667Sonopet iQ Sterilization TrayParagon Medical20190

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 6 companies; a new generation was cleared every 3.1 years on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K190667 (Paragon Medical, 2019) has gone furthest, with 0 descendants of its own.

How does its category compare?

All KCT devices

KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · KCT

11in 2025

2007: 32008: 62009: 62010: 122011: 62012: 102013: 82014: 112015: 152016: 122017: 102018: 152019: 182020: 142021: 182022: 112023: 102024: 82025: 112026 (partial year): 9
2007high 18 (2019) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KCT

205in 2025

2007: 199 days median2008: 182 days median2009: 89 days median2010: 202 days median2011: 117 days median2012: 236 days median2013: 131 days median2014: 169 days median2015: 151 days median2016: 182 days median2017: 211 days median2018: 192 days median2019: 187 days median2020: 134 days median2021: 185 days median2022: 137 days median2023: 94 days median2024: 106 days median2025: 205 days median2026 (partial year): 122 days median
2007high 236 (2012) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KCT

17in 2022

2010: 12011: 22013: 12014: 12016: 32017: 12021: 12022: 17
2007high 17 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KCT

50in 2025

2007: 22008: 82009: 52010: 32011: 32012: 22013: 62014: 52015: 62016: 162017: 32018: 222019: 152020: 662021: 262022: 82023: 302024: 182025: 50
2007high 66 (2020) · low 2 (2007)2025

MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007319902
2008618208
200968905
20101220213
2011611723
20121023602
2013813116
20141116915
20151515106
201612182316
20171021113
201815192022
201918187015
202014134066
202118185126
202211137178
20231094030
20248106018
202511205050
202691220—

What is it indicated for?

The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are intended to enclose and organize Stryker Endoscopy reusable medical instruments during sterilization at a healthcare facility. The trays are optional accessories to the Stryker Endoscopy instruments for which they are designed. The trays are not intended to maintain sterility; they are intended to be used in conjunction with…

Read the full statement (449 words)

The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are intended to enclose and organize Stryker Endoscopy reusable medical instruments during sterilization at a healthcare facility. The trays are optional accessories to the Stryker Endoscopy instruments for which they are designed. The trays are not intended to maintain sterility; they are intended to be used in conjunction with legally marketed, FDA-cleared sterilization wrap in order to maintain sterility of the enclosed devices. The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are intended for use in any of the following standard sterilization machines / cycles:

No Method Cycle

1 Ethylene Oxide (EtO) Preconditioning Parameters

Temperature (°C) 55°C (131°F)

Chamber Humidity 70% RH

Vacuum Set Points 1.3 psia

Time 30 minutes

Exposure

Concentration 725 mg/L, 100% EO

Temperature (°C) 55°C +2°C (131°F +5°F)

Time 1 hour

Chamber Humidity (%) 70% RH (50-80%) +5%

Aeration

Aeration Time 12 hours

Temperature 35°C - 54°C (95°F – 129°F)

2 Prevacuum Steam Cycle 1 Cycle 2

Wrapping Double Double

Temperature 132°C (270°F) 134°C (273°F)

Sterilization Time 4 minutes 3 minutes

Dry Time 30 minutes 30 minutes

3 Gravity Steam Cycle 1 Cycle 2

Wrapping Double Double

Temperature 132°C (270°F) 134°C (273°F)

Sterilization Time 15 minutes 10 minutes

Dry Time 30 minutes 30 minutes

4 STERIS® V-PRO® 1 Standard

5 STERIS® V-PRO® 1 Plus Non-Lumen or Lumen

6 STERIS® V-PRO® maX Non-Lumen or Lumen

7 STERRAD® 100S Standard

8 STERRAD® NX® Standard

9 STERRAD® 100NX® Standard

In addition, the Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are validated for the following Immediate Use Steam Sterilization cycles for emergency situations ONLY.

Method Cycle

Immediate Use Steam Sterilization (“Flash”) Cycle 1 Cycle 2

Wrapping None None

Prevacuum Steam

Temperature 132°C (270°F) 134°C (273°F)

Sterilization Time 4 minutes 3 minutes

Dry Time None None

The maximum product loads for the trays are as follows:

Tray Description | Catalog Number | Maximum Tray Product Load | Total Loaded Tray Weight

Advanced Imaging Modality (AIM) Sterilization Tray | 0233-032-301 | Camera (Qty. 1), Light Cable (Qty. 1), Coupler (Qty. 1), Scope (Qty. 2), Adapter (Qty. 2) | 10.58 lbs

Endoscope and Camera Sterilization Tray | 233-032-302 | Camera (Qty. 1), Light Cable (Qty. 1), Coupler (Qty. 1), Scope (Qty. 2), Adapter (Qty. 2) | 10.58 lbs

Camera Sterilization Tray | 0233-410-002 | Camera (Qty. 1), Light Cable (Qty. 1), Coupler (Qty. 1) | 8.83 lbs

* Validated worst case loading configuration included the Advanced Imaging Modality (AIM) Sterilization Tray containing a camera (Qty. 1), light cable (Qty. 1), coupler (Qty. 2), scope (Qty. 3) and adapter (Qty. 3).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K152951: Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, Camera Sterilization Tray.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K152951

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026