510(k) Report

510(k) · Cleared

Cleared

IDSS ForceTriad Control Module

K153205510(k) TraditionalCleared Aug 1, 2016271-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Black Diamond Video, Inc. · ODA Endoscopic Central Control Unit

Cleared on Aug 1, 2016 as substantially equivalent to K111165 (KARL STORZ Endoscopy-America, Inc., 2012) after a 271-day review. Its family tree reaches back 2 generations to 2008.

Decided
Aug 1, 2016
Review
271 days
Class
Class II
Product code
ODA
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K080410 (2008). No later device cites it as a predicate yet.

  1. Root · 2 generations backK080410 Karl Storz SCB/Conmed Esu Interface Module, Model 20091522KARL STORZ Endoscopy-America, Inc. · 2008
  2. 1 generation backK111165 Karl Storz SCB / Covidien Forcetriad Interface ModuleKARL STORZ Endoscopy-America, Inc. · 2012
  3. This deviceK153205 IDSS ForceTriad Control ModuleBlack Diamond Video, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K080410Karl Storz SCB/Conmed Esu Interface Module, Model 20091522KARL STORZ Endoscopy-America, Inc.2008—
−1K111165Karl Storz SCB / Covidien Forcetriad Interface ModuleKARL STORZ Endoscopy-America, Inc.2012—
0 (this device)K153205IDSS ForceTriad Control ModuleBlack Diamond Video, Inc.2016—
FIG. 1 — Lineage of K153205, 2008–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODA device

  1. #1 K203566 Tablet Applicationscore 6.7 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K111165Karl Storz SCB / Covidien Forcetriad Interface Module
Summary page 4
…21 CFR 876.1500 Class: 2 Product Code: ODA Predicate Device : Karl Storz SCB/Covidien ForceTriad Interface Module (K111165) Device Description: The IDSS ForceTriad Control Module is an additional function to the IDSS, which is an i…
KARL STORZ Endoscopy-America, Inc.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 2 companies; a new generation was cleared every 4.6 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All ODA devices

ODA Endoscopic Central Control Unit: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · ODA

1in 2023

2007: 12008: 12009: 12010: 12011: 12012: 12016: 22020: 12021: 12022: 12023: 1
2007high 2 (2016) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODA

Too few ODA 510(k)s in any year since 2007 to give a median.

Recalls per year · ODA

No recall names ODA since 2007.

Adverse event reports per year · ODA

3in 2025

2009: 22010: 12011: 22012: 12015: 12017: 12025: 3
2007high 3 (2025) · low 0 (2007)2025

MAUDE reports naming product code ODA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
20091—02
20101—01
20111—02
20121—01
20130—00
20140—00
20150—01
20162—00
20170—01
20180—00
20190—00
20201—00
20211—00
20221—00
20231—00
20240—00
20250—03
20260—0—

What is it indicated for?

The IDSS-ForceTriad Control Module is designed for integration in the IDSS (Integrated Digital Surgical Suite) and enables the Covidien ForceTriad Energy Platform to be controlled remotely.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K153205: IDSS ForceTriad Control Module.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K153205

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026