K153685510(k) TraditionalCleared Oct 13, 2016296-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sunny Medical Device (Shenzhen) Co., Ltd. · DQX Wire, Guide, Catheter

Cleared on Oct 13, 2016 as substantially equivalent to K113148 (Synexmed (Shenzhen)Company Limited, 2012) and 1 other predicate after a 296-day review. Its family tree reaches back 4 generations to 1985.

Decided
Oct 13, 2016
Review
296 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K854261 (1985). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK854261 Advanced Cardiovascular Systems Hemostatic ValvesAdvanced Cardiovascular Systems, Inc. · 1985 · Recalled
  2. 3 generations backK991102 Copilot Bleedback Control Valve, Model 1003331Guidant Corp. · 1999 · Recalled
  3. 2 generations backK042060 Easypass US Y-Connector Hemostatic ValveMillimed A/S · 2004
  4. 1 generation backK113148 E-PASSSynexmed (Shenzhen)Company Limited · 2012
  5. This deviceK153685 Sunmed Haemostatic ValvesSunny Medical Device (Shenzhen) Co., Ltd. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K854261Advanced Cardiovascular Systems Hemostatic ValvesAdvanced Cardiovascular Systems, Inc.19852
−3K991102Copilot Bleedback Control Valve, Model 1003331Guidant Corp.19991
−2K042060Easypass US Y-Connector Hemostatic ValveMillimed A/S2004—
−1K113148E-PASSSynexmed (Shenzhen)Company Limited2012—
0 (this device)K153685Sunmed Haemostatic ValvesSunny Medical Device (Shenzhen) Co., Ltd.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K153685, 1985–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K113148E-PASS
Summary page 4
…Trade Name Manufacture Note Number Synexmed (Shenzhen) company K113148 E-PassTM Primary predicate l…
Synexmed (Shenzhen)Company Limited2012—
*K131124Colign
Summary page 5
…Shenzhen) Co., Ltd. Traditional 510(k) Sunny Medical Device (Shenzhen) Co., Ltd. CoLignTM Hemostasis K131124 Jilin Coronado Medical Ltd. Valve The LiiSA Lever K073260…
Jilin Coronado Medical, Ltd.2013—
†K073260Liisa Lever Integrated Interventional System Adapter, Model VSL-109Device Partners International2008—
†K052381Guardian Hemostasis Valve with Guidewire IntroducerZerusa Limited2005—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 5 companies; a new generation was cleared every 7.4 years on median.
  • 2 of the 5 ancestors have a recall of any class.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

The SunmedTM Haemostatic Valves is intended to maintain hemostasis during the introduction/withdrawal and use of diagnostic and interventional devices up to an external diameter of 7 Fr, 8 Fr or 9 Fr; The insertion tool facilitates introduction of guide wire through the haemostatic valves to reach the guiding catheter; The torquer provides a handle for easier manipulation of the guide wire when inserted into the proximal end of the guide wire.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K153685: Sunmed Haemostatic Valves.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K153685

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026