ClearedBLE Smart Blood Glucose Monitoring System, BLE Smart Professional Blood Glucose Monitoring System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Infopia Co, Ltd. · NBW System, Test, Blood Glucose, Over The Counter
Cleared on Sep 28, 2016 as substantially equivalent to K130181 (Infopia Co, Ltd., 2013) after a 232-day review. Its family tree reaches back 2 generations to 2006.
- Decided
- Sep 28, 2016
- Review
- 232 days
- Class
- Class II
- Product code
- NBW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K062058 (2006). No later device cites it as a predicate yet.
- Root · 2 generations backK062058 Ascensia Contour Blood Glucose Meter, Model 7151; Reagent Strip…Bayer Healthcare · 2006 · Recalled
- 1 generation backK130181 Gluneo Blood Glucose Monitoring System, and Professional Blood…Infopia Co, Ltd. · 2013
- This deviceK160365 BLE Smart Blood Glucose Monitoring System, BLE Smart Professional…Infopia Co, Ltd. · 2016
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K062058 | Ascensia Contour Blood Glucose Meter, Model 7151; Reagent Strip, Model 7080 | Bayer Healthcare | 2006 | 2 |
| −1 | K130181 | Gluneo Blood Glucose Monitoring System, and Professional Blood Glucose… | Infopia Co, Ltd. | 2013 | — |
| 0 (this device) | K160365 | BLE Smart Blood Glucose Monitoring System, BLE Smart Professional Blood… | Infopia Co, Ltd. | 2016 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NBW device
- #1 K260545 CONTOUR® PLUS BLUE Blood Glucose Monitoring…score 14.6 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K130181 | Gluneo Blood Glucose Monitoring System, and Professional Blood Glucose Monitoring SystemSummary page 5… Classification regulation: 21 CFR Part 862.1345, 21 CFR Part 862.1660 Product Code: NBW, LFR, JJX 4. Predicate Device: K130181, GluNEO™ Blood Glucose Monitoring System & GluNEO™ Professional Blood Glucose Monitoring System by Infopia Co., Ltd.… | 2013 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 2 companies; a new generation was cleared every 6.9 years on median.
- 1 of the 2 ancestors has a recall of any class.
- 1 other device also cites its predicate K130181.
How does its category compare?
All NBW devicesNBW System, Test, Blood Glucose, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · NBW
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NBW
243in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NBW
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · NBW
4,745in 2025
MAUDE reports naming product code NBW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 29 | 85 | 9 | 7,991 |
| 2008 | 37 | 128 | 2 | 7,704 |
| 2009 | 38 | 140 | 5 | 10,963 |
| 2010 | 31 | 132 | 11 | 11,631 |
| 2011 | 30 | 328 | 1 | 22,909 |
| 2012 | 30 | 230 | 1 | 23,449 |
| 2013 | 47 | 167 | 5 (2) | 35,408 |
| 2014 | 24 | 202 | 1 | 38,524 |
| 2015 | 32 | 237 | 0 | 62,111 |
| 2016 | 20 | 233 | 1 | 76,621 |
| 2017 | 25 | 244 | 0 | 37,538 |
| 2018 | 19 | 168 | 0 | 16,911 |
| 2019 | 10 | 127 | 14 | 14,472 |
| 2020 | 7 | 121 | 0 | 10,703 |
| 2021 | 7 | 465 | 0 | 9,198 |
| 2022 | 12 | 410 | 0 | 8,103 |
| 2023 | 5 | 193 | 0 | 7,256 |
| 2024 | 7 | 243 | 0 | 6,220 |
| 2025 | 2 | — | 1 | 4,745 |
| 2026 | 5 | 190 | 0 | — |
What is it indicated for?
BLE Smart Blood Glucose Monitoring System The BLE Smart Blood Glucose Monitoring System is intended for the quantitative measurement of glucose (sugar) in fresh capillary whole blood from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and thigh. The BLE Smart Blood Glucose Monitoring System is intended to be used by a single patient and should not be shared. The BLE Smart Blood Glucose Monitoring System is intended for testing…
Read the full statement (432 words)
BLE Smart Blood Glucose Monitoring System
The BLE Smart Blood Glucose Monitoring System is intended for the quantitative measurement of glucose (sugar) in fresh capillary whole blood from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and thigh. The BLE Smart Blood Glucose Monitoring System is intended to be used by a single patient and should not be shared. The BLE Smart Blood Glucose Monitoring System is intended for testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of diabetes control. It should not be used for the diagnosis of or screening of diabetes or for neonatal use. Alternative site testing should be done only during steady–state times (when glucose is not changing rapidly).
The BLE Smart Blood Glucose Test Strips are for use with the BLE Smart Meter to quantitatively measure glucose in fresh capillary whole blood. Fresh capillary whole blood samples may be drawn from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and thigh.
The BLE Smart Blood Glucose Control Solutions are for use with the BLE Smart Blood Glucose Monitoring System to check that the meter and test strips are working together properly and the test is performing correctly.
BLE Smart Professional Blood Glucose Monitoring System
The BLE Smart Professional Blood Glucose Monitoring System is intended for the quantitative measurement of glucose in capillary whole blood from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and thigh and in venous whole blood. The BLE Smart Professional Blood Glucose Monitoring System is intended for testing outside the body (in vitro diagnostic use) and is intended for multiple-patient use in professional healthcare settings as an aid to monitor the effectiveness of diabetes control program. This system should only be used with auto-disabling, single-use lancing devices. The BLE Smart Professional Blood Glucose Monitoring System should not be used for the diagnosis of or screening of diabetes or for neonatal use. Alternative site testing should be done only during steady – state times (when glucose is not changing rapidly).
The BLE Smart Professional Blood Glucose Test Strips are for use with the BLE Smart Professional Meter to quantitatively measure glucose in venous whole blood samples and fresh capillary whole blood samples drawn from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and/or thigh.
The BLE Smart Professional Blood Glucose Control Solutions are for use with the BLE Smart Professional Blood Glucose Monitoring System to check that the meter and test strips are working together properly and that the test is performing correctly.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K160365 · printed Nov 4, 2026
Cite this page
510(k) Report. “K160365: BLE Smart Blood Glucose Monitoring System, BLE Smart Professional Blood Glucose Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K160365
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026