Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Trident S.R.L · MUH System, X-Ray, Extraoral Source, Digital

Cleared on Mar 10, 2016 as substantially equivalent to K143703 (Nical Spa, 2015) after a 28-day review. Its family tree reaches back 4 generations to 1994.

Decided
Mar 10, 2016
Review
28 days
Class
Class II
Product code
MUH
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K934949 (1994). No later device cites it as a predicate yet.

  1. Root · 4 generations backK934949 DigoraOrion Corporation Soredex · 1994
  2. 3 generations backK041050 Digora Optime (or Digora Ontime)Soredex Palodex Group OY · 2004 · Recalled
  3. 2 generations backK131442 Firecr Dentalimaging System3Disc Americas · 2013
  4. 1 generation backK143703 NICAL SMART MICRO CR system for intraoral dental imagesNical Spa · 2015
  5. This deviceK160386 ReadeR, VieweR, QuickScan PSPTrident S.R.L · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K934949DigoraOrion Corporation Soredex1994—
−3K041050Digora Optime (or Digora Ontime)Soredex Palodex Group OY20044
−2K131442Firecr Dentalimaging System3Disc Americas2013—
−1K143703NICAL SMART MICRO CR system for intraoral dental imagesNical Spa2015—
0 (this device)K160386ReadeR, VieweR, QuickScan PSPTrident S.R.L2016—
FIG. 1 — Lineage of K160386, 1994–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUH device

  1. #1 K242778 X Sensor (Model: IOS-A15IF, HDI-15DGF)score 16.0 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143703NICAL SMART MICRO CR system for intraoral dental images
Summary page 5
…5.0-1 Predicate Device The subject device claims equivalence to the following legally marketed predicate: 510(k) Number: K143703 Date Cleared March 18, 2015 Trade Name: NICAL SMART MICRO CR System for Intraoral Dental…
Nical Spa2015—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 5 companies; a new generation was cleared every 9.2 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All MUH devices

MUH System, X-Ray, Extraoral Source, Digital: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · MUH

3in 2025

2007: 112008: 82009: 92010: 92011: 102012: 92013: 92014: 82015: 122016: 62017: 92018: 32019: 52020: 52021: 102022: 72023: 112024: 42025: 32026 (partial year): 2
2007high 12 (2015) · low 3 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUH

159in 2025

2007: 48 days median2008: 64 days median2009: 88 days median2010: 174 days median2011: 89 days median2012: 81 days median2013: 172 days median2014: 168 days median2015: 111 days median2016: 47 days median2017: 84 days median2018: 29 days median2019: 64 days median2020: 36 days median2021: 80 days median2022: 57 days median2023: 57 days median2024: 144 days median2025: 159 days median
2007high 174 (2010) · low 29 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUH

1in 2015

2008: 12009: 22013: 12014: 12015: 1
2007high 2 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUH

1in 2025

2009: 122010: 92012: 52013: 12014: 52015: 32016: 12017: 42018: 102019: 62021: 12023: 12025: 1
2007high 12 (2009) · low 0 (2007)2025

MAUDE reports naming product code MUH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007114800
200886410
2009988212
2010917409
2011108900
201298105
2013917211
2014816815
20151211113
201664701
201798404
2018329010
201956406
202053600
2021108001
202275700
2023115701
2024414400
2025315901
20262—0—

What is it indicated for?

ReadeR is a dental imaging system indicated for capturing, digitization and processing of intra oral x-ray images stored in imaging plate recording media.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K160386: ReadeR, VieweR, QuickScan PSP.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K160386

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026