OptiCross 18, 30 MHz Peripheral Imaging Catheter

K160514510(k) TraditionalCleared Jun 22, 2016119-day reviewClass II21 CFR 870.1200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corporation · OBJ Catheter, Ultrasound, Intravascular

Cleared on Jun 22, 2016 as substantially equivalent to K073623 (Boston Scientific Corp, 2008) after a 119-day review. Its family tree reaches back 3 generations to 1997. 1 later device descends from it.

Decided
Jun 22, 2016
Review
119 days
Class
Class II
Product code
OBJ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K970049 (1997). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK970049 BSC, Sonicath Ultra Imaging Catheter 3.2F/20MHZ (37410/456221 & BSC…Cardiovascular Imaging Systems, Inc. · 1997
  2. 2 generations backK060947 Sonicath Ultra Imaging Catheter, 3.2F,20MHZ Models 37410/456221/C1020Boston Scientific Corp · 2006
  3. 1 generation backK073623 Atlantis 018 Peripheral Imaging CatheterBoston Scientific Corp · 2008
  4. This deviceK160514 OptiCross 18, 30 MHz Peripheral Imaging CatheterBoston Scientific Corporation · 2016
  5. Descendant · cites it directly · 0 of its ownK222568 OptiCross™ 18 Peripheral Imaging CatheterBoston Scientific Corporation · 2022

Most influential descendants

Showing 1 of 1 · See all
  • K222568OptiCross™ 18 Peripheral Imaging CatheterBoston Scientific Corporation · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K970049BSC, Sonicath Ultra Imaging Catheter 3.2F/20MHZ (37410/456221 & BSC, Sonicath…Cardiovascular Imaging Systems, Inc.1997—
−2K060947Sonicath Ultra Imaging Catheter, 3.2F,20MHZ Models 37410/456221/C1020Boston Scientific Corp2006—
−1K073623Atlantis 018 Peripheral Imaging CatheterBoston Scientific Corp2008—
0 (this device)K160514OptiCross 18, 30 MHz Peripheral Imaging CatheterBoston Scientific Corporation2016—
+1K222568OptiCross™ 18 Peripheral Imaging CatheterBoston Scientific Corporation2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
FIG. 1 — Lineage of K160514, 1997–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OBJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OBJ device

  1. #1 K242893 VERAFEYE System VERAFEYE Imaging Catheter &…score 23.8 · 30 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073623Atlantis 018 Peripheral Imaging Catheter
Summary page 4
…as Class II per 21 CFR 892.1570. Predicate Atlantis™ 018 K073623 13-Mar-2008 Device Peripheral Imaging Catheter Reference OptiCross™ 40 MHz…
Boston Scientific Corp2008—
†K123621Opticross 40 MHZ Coronary Imaging CatheterBoston Scientific Corp20131
†K060947Sonicath Ultra Imaging Catheter, 3.2F,20MHZ Models 37410/456221/C1020Boston Scientific Corp2006—
†K153617OptiCross 6, 40 MHz Coronary Imaging Catheter (US Distribution), OptiCross 6, 40 MHz…Boston Scientific Corporation2016—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K222568OptiCross™ 18 Peripheral Imaging CatheterBoston Scientific Corporation20220

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 8.3 years on median.
  • 2 of the 5 ancestors have a recall of any class.
  • Of its descendants, K222568 (Boston Scientific Corporation, 2022) has gone furthest, with 0 descendants of its own.

How does its category compare?

All OBJ devices

OBJ Catheter, Ultrasound, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · OBJ

7in 2025

2007: 32008: 62009: 32010: 12011: 42012: 32013: 42014: 32015: 42016: 42017: 62018: 22019: 12020: 42021: 32022: 32023: 32024: 32025: 72026 (partial year): 4
2007high 7 (2025) · low 1 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OBJ

35in 2025

2007: 74 days median2008: 100 days median2009: 108 days median2011: 109 days median2012: 136 days median2013: 96 days median2014: 30 days median2015: 131 days median2016: 94 days median2017: 45 days median2020: 135 days median2021: 29 days median2022: 63 days median2023: 63 days median2024: 131 days median2025: 35 days median2026 (partial year): 81 days median
2007high 136 (2012) · low 29 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OBJ

2in 2020

2015: 22017: 22018: 22020: 22026 (partial year): 1, 1 Class I
2007high 2 (2015) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · OBJ

791in 2025

2008: 62009: 222010: 392011: 472012: 532013: 3282014: 6092015: 4012016: 5152017: 5242018: 5422019: 2372020: 2882021: 3532022: 4732023: 6972024: 1,1542025: 791
2007high 1,154 (2024) · low 0 (2007)2025

MAUDE reports naming product code OBJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200737400
2008610006
20093108022
20101—039
20114109047
20123136053
20134960328
20143300609
201541312401
20164940515
20176452524
20182—2542
20191—0237
202041352288
20213290353
20223630473
20233630697
2024313101,154
20257350791
20264811 (1)—

What is it indicated for?

OptiCross™ 18 is intended for intravascular ultrasound examination of peripheral vessels only. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal interventional procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K160514: OptiCross 18, 30 MHz Peripheral Imaging Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K160514

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026