510(k) Report

510(k) · Cleared

Cleared

Sumitomo Proton Therapy System

K160612510(k) TraditionalCleared Aug 17, 2016167-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sumitomo Heavy Industries, Ltd. · LHN System, Radiation Therapy, Charged-Particle, Medical

Cleared on Aug 17, 2016 as substantially equivalent to K130426 (Sumitomo Heavy Industries, Ltd., 2013) after a 167-day review. Its family tree reaches back 4 generations to 1988.

Decided
Aug 17, 2016
Review
167 days
Class
Class II
Product code
LHN
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K872369 (1988). 6 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK872369 Loma Linda Univ. Proton Beam Therapy SystemLoma Linda University Medical Center · 1988
  2. 3 generations backK992414 Proton Beam Therapy System (PBTS)Optivus Technology, Inc. · 2000
  3. 2 generations backK053280 ProbeatHitachi, Ltd., Power Systems Group · 2006
  4. 1 generation backK130426 Sumitomo Proton Therapy SystemSumitomo Heavy Industries, Ltd. · 2013
  5. This deviceK160612 Sumitomo Proton Therapy SystemSumitomo Heavy Industries, Ltd. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K872369Loma Linda Univ. Proton Beam Therapy SystemLoma Linda University Medical Center1988—
−3K992414Proton Beam Therapy System (PBTS)Optivus Technology, Inc.2000—
−2K053280ProbeatHitachi, Ltd., Power Systems Group2006—
−1K130426Sumitomo Proton Therapy SystemSumitomo Heavy Industries, Ltd.2013—
0 (this device)K160612Sumitomo Proton Therapy SystemSumitomo Heavy Industries, Ltd.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200120
FIG. 1 — Lineage of K160612, 1988–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LHN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LHN device

  1. #1 K260597 Virtue QAscore 15.4 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130426Sumitomo Proton Therapy System
Summary page 4
…egulation: 21 CFR 892.5050 Product Code: LHN 3. PREDICATE DEVICE • Sumitomo Proton Therapy System, Sumitomo Heavy Industries, Ltd. (K130426) • IBA Proton Therapy System- Proteus 235, Ion Beam Applications, S.A. (K082416) 4. DEVICE DESCRIPTION The Sumitomo Pr…
Sumitomo Heavy Industries, Ltd.2013—
†K082416Iba Proton Therapy System- Proteus 235Ion Beam Applications S.A.20083

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 7.7 years on median.
  • None of the 6 ancestors has a recall.

How does its category compare?

All LHN devices

LHN System, Radiation Therapy, Charged-Particle, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · LHN

3in 2025

2007: 22008: 32009: 52010: 42011: 12012: 32013: 32014: 42015: 32016: 72017: 42018: 32019: 22020: 42022: 22023: 22024: 12025: 32026 (partial year): 4
2007high 7 (2016) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LHN

190in 2025

2008: 113 days median2009: 69 days median2010: 96 days median2012: 111 days median2013: 70 days median2014: 93 days median2015: 53 days median2016: 120 days median2017: 173 days median2018: 78 days median2020: 74 days median2025: 190 days median2026 (partial year): 194 days median
2007high 194 (2026) · low 53 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LHN

1in 2023

2007: 22008: 22014: 22015: 12017: 52018: 22020: 12021: 12022: 22023: 1
2007high 5 (2017) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LHN

11in 2025

2008: 12009: 52010: 32011: 12012: 12013: 12014: 52015: 22016: 12017: 72018: 82019: 32020: 202021: 242022: 102023: 72024: 22025: 11
2007high 24 (2021) · low 0 (2007)2025

MAUDE reports naming product code LHN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—20
2008311321
200956905
201049603
20111—01
2012311101
201337001
201449325
201535312
2016712001
2017417357
201837828
20192—03
2020474120
20210—124
20222—210
20232—17
20241—02
20253190011
202641940—

What is it indicated for?

The Sumitomo Proton Therapy System is a medical device designed to produce and deliver a proton beam for treatment of patients with localized tumors and other conditions susceptible to treatment by radiation.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K160612: Sumitomo Proton Therapy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K160612

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026