Inclusive Abutments

K160979510(k) TraditionalCleared Nov 4, 2016211-day reviewClass II21 CFR 872.3630

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Prismatik Dentalcraft, Inc. · NHA Abutment, Implant, Dental, Endosseous

Cleared on Nov 4, 2016 after a 211-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 6 later devices descend from it.

Decided
Nov 4, 2016
Review
211 days
Class
Class II
Product code
NHA
Recalls
None
Predicates
0

6 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2019: 1 descendant cleared2023: 2 descendants cleared2025: 1 descendant cleared2024: 1 descendant cleared201620182020202220242026
  1. This deviceK160979 Inclusive AbutmentsPrismatik Dentalcraft, Inc. · 2016
  2. Descendant · cites it directly · 5 of its ownK170044 Inclusive Titanium Abutments compatible with: MegaGen AnyRidge…Prismatik Dentalcraft, Inc. · 2017
  3. Descendant · 2 generations on · 4 of its ownK191222 Inclusive Titanium Abutments compatible with: Dentsply Implants…Prismatik Dentalcraft, Inc. · 2019
  4. Descendant · 3 generations on · 0 of its ownK252582 Inclusive® Titanium Abutments compatible with: Camlog® CONELOG®…Prismatik Dentalcraft, Inc. · 2025
  5. Descendant · 3 generations on · 0 of its ownK240240 Inclusive® Titanium Abutments compatible with: Keystone® Dental…Prismatik Dentalcraft, Inc. · 2024
  6. Descendant · 3 generations on · 0 of its ownK231097 Inclusive® Titanium Abutments compatible with: Neoss® ProActive®…Prismatik Dentalcraft, Inc. · 2023

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2017: 12019: 12023: 22024: 12025: 1
2017high 2 (2023) · low 0 (2018)2026

Most influential descendants

Showing 5 of 6 · See all
  • K170044Inclusive Titanium Abutments compatible with: MegaGen AnyRidge Implant SystemPrismatik Dentalcraft, Inc. · 2017 · cites it directly5descendants
  • K191222Inclusive Titanium Abutments compatible with: Dentsply Implants Astra Tech Implant…Prismatik Dentalcraft, Inc. · 2019 · 2 generations on4descendants
  • K252582Inclusive® Titanium Abutments compatible with: Camlog® CONELOG® Implant System, Dentium®…Prismatik Dentalcraft, Inc. · 2025 · 3 generations on0descendants
  • K240240Inclusive® Titanium Abutments compatible with: Keystone® Dental PrimaConnex®, Neodent®…Prismatik Dentalcraft, Inc. · 2024 · 3 generations on0descendants
  • K231097Inclusive® Titanium Abutments compatible with: Neoss® ProActive® Narrow, Neoss®…Prismatik Dentalcraft, Inc. · 2023 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K160979Inclusive AbutmentsPrismatik Dentalcraft, Inc.2016—
+1K170044Inclusive Titanium Abutments compatible with: MegaGen AnyRidge Implant SystemPrismatik Dentalcraft, Inc.2017—
+2K191222Inclusive Titanium Abutments compatible with: Dentsply Implants Astra Tech…Prismatik Dentalcraft, Inc.2019—
+3K252582Inclusive® Titanium Abutments compatible with: Camlog® CONELOG® Implant…Prismatik Dentalcraft, Inc.2025—
+3K240240Inclusive® Titanium Abutments compatible with: Keystone® Dental PrimaConnex®…Prismatik Dentalcraft, Inc.2024—
+3K231097Inclusive® Titanium Abutments compatible with: Neoss® ProActive® Narrow…Prismatik Dentalcraft, Inc.2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
201910
202320
202410
202510
FIG. 1 — Lineage of K160979, 2016–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NHA device

  1. #1 K222288 DESS Dental Smart Solutionsscore 30.6 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (6)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K170044Inclusive Titanium Abutments compatible with: MegaGen AnyRidge Implant SystemPrismatik Dentalcraft, Inc.20175

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K170044 (Prismatik Dentalcraft, Inc., 2017) has gone furthest, with 5 descendants of its own.

How does its category compare?

All NHA devices

NHA Abutment, Implant, Dental, Endosseous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · NHA

40in 2025

2007: 382008: 312009: 302010: 192011: 312012: 252013: 222014: 272015: 292016: 382017: 312018: 312019: 282020: 382021: 292022: 332023: 512024: 432025: 402026 (partial year): 23
2007high 51 (2023) · low 19 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHA

147in 2025

2007: 91 days median2008: 90 days median2009: 95 days median2010: 162 days median2011: 130 days median2012: 171 days median2013: 184 days median2014: 160 days median2015: 151 days median2016: 202 days median2017: 188 days median2018: 200 days median2019: 160 days median2020: 153 days median2021: 211 days median2022: 142 days median2023: 147 days median2024: 158 days median2025: 147 days median2026 (partial year): 169 days median
2007high 211 (2021) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NHA

1in 2025

2007: 12008: 22011: 52012: 12013: 12015: 12016: 362017: 22018: 12020: 72023: 32025: 12026 (partial year): 3
2007high 36 (2016) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NHA

838in 2025

2007: 12008: 82009: 302010: 612011: 562012: 52013: 1432014: 1462015: 8582016: 3142017: 5772018: 5912019: 5302020: 4582021: 5462022: 4972023: 6182024: 6352025: 838
2007high 858 (2015) · low 1 (2007)2025

MAUDE reports naming product code NHA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007389111
2008319028
20093095030
201019162061
201131130556
20122517115
2013221841143
2014271600146
2015291511858
20163820236314
2017311882577
2018312001591
2019281600530
2020381537458
2021292110546
2022331420497
2023511473618
2024431580635
2025401471838
2026231693—

What is it indicated for?

Inclusive” Abutments are premanufactured prosthetic components connected to endosseous dental implants in the edentulous or partially edentulous maxilla or mandible to provide support for cement-retained or screw-retained prosthetic restorations. Compatible Implant System Implant Diameter (mm) Platform Diameter (mm) Astra Tech OsseoSpeed™ 3.0,3.5,4.0,4.5,5.0 3.0,3.5,4.0,4.5,5.0 Biomet 3i Osseotite” Certain” 3.25,4.0,5.0,6.0 3.4,4.1,5.0,6.0 Camlog…

Read the full statement (141 words)

Inclusive” Abutments are premanufactured prosthetic components connected to endosseous dental implants in the edentulous or partially edentulous maxilla or mandible to provide support for cement-retained or screw-retained prosthetic restorations.

Compatible Implant System Implant Diameter (mm) Platform Diameter (mm)

Astra Tech OsseoSpeed™ 3.0,3.5,4.0,4.5,5.0 3.0,3.5,4.0,4.5,5.0

Biomet 3i Osseotite” Certain” 3.25,4.0,5.0,6.0 3.4,4.1,5.0,6.0

Camlog Screw-line 3.3,3.8,4.3,5.0,6.0 3.3,3.8,4.3,5.0,6.0

Dentsply Ankylos 3.5,4.5,55,7.0 3.5,4.5,5.5,7.0

Hahn Tapered Implant System 3.0,3.5,4.3,5.0,7.0 3.0,3.5,4.3,5.0,7.0

Hiossen HG Implant System mini, standard 3.5,4.0,45,5.0 37,4.2,4.6,5.1

Inclusive Tapered Implant System 3.7,4.7,5.2 35,45

Nobel Biocare Branemark RP 3.75,4.0 4.1

Nobel Biocare NobelActive™ NP, RP 35,43,5.0 35,39

Nobel Biocare NobelReplace™ NP, RP, WP, 6.0 3.5,4.3,5.0,6.0 3.5,4.3,5.0,6.0

Straumann Bone Level NC, RC 33,4.1,4.8 33,4.1,4.8

Straumann synOcta RN, WN 4.1,4.8 4.8,6.5

Zimmer Screw-Vent® 37,4.1,4.7,6.0 3.5,4.5,5.7

All digitally designed abutments for use with Inclusive® Abutments for CAD/CAM are intended to be sent to a Prismatik Dentalcraft validated milling center for manufacture.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K160979: Inclusive Abutments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K160979

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026