510(k) Report

510(k) · Cleared

Cleared

PK Morcellator

K161038510(k) TraditionalCleared Oct 7, 2016177-day reviewClass II21 CFR 878.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gyrus Acmi, Inc. · GEI Electrosurgical, Cutting & Coagulation & Accessories

Cleared on Oct 7, 2016 as substantially equivalent to K080093 (Gyrus Acmi, Inc., 2008) after a 177-day review. Its family tree reaches back 10 generations to 1994.

Decided
Oct 7, 2016
Review
177 days
Class
Class II
Product code
GEI
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K936109 (1994). 70 ancestors in all, the oldest K800617 (1980). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 11 other ancestors2003: 2 other ancestors2002: 2 other ancestors2001: 3 other ancestors1998: 6 other ancestors1997: 4 other ancestors1991: 4 other ancestors1996: 8 other ancestors1995: 7 other ancestors1994: 4 other ancestors1992: 3 other ancestors1999: 1 other ancestor1980: 1 other ancestor1993: 1 other ancestor1990: 1 other ancestor1989: 1 other ancestor1986: 1 other ancestorK936109 · Sharplan Model 1120 CO2 Surgical Laser · Sharplan Lasers, Inc. · 1994K960521 · Sharplan Lasers, Inc. Silktouch Flash Scanner · Sharplan Lasers, Inc. · 1996K963339 · Coherent Ultrapulse CO2 Surgical Lasers · Coherent Medical Group · 1997K974789 · Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and L · Lumenis, Inc. · 1998K990947 · Modified Versapulse Select Single Wavelength, HO: Yag and Dual Wavelength, HO: Yag/ND: Yag Surgical Lasers and Delivery · Lumenis, Inc. · 1999K011703 · Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength (HO:Yag/ND:Yag) Surgical Lasers and Delivery Devices · Lumenis · 2001 · recalledK014290 · Entec Plasma Wands · Arthrocare Corp. · 2002K021777 · Gyrus Ent Cogent 2/G2 System (Generator,Accessories Somnoplasty Electrodes and Plasmacision Electrodes) · Gyrus Ent LLC · 2002K041633 · Gyrus Plasmacision Laparoscopic Spatula · Gyrus Medical, Inc. · 2004K080093 · PKS Plasma Morcellator, Models 962000PK, 3620PK · Gyrus Acmi, Inc. · 20081980199020002010
  1. Root · 10 generations backK936109 Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc. · 1994
  2. 6 generations between
  3. 3 generations backK021777 Gyrus Ent Cogent 2/G2 System (Generator,Accessories Somnoplasty…Gyrus Ent LLC · 2002
  4. 2 generations backK041633 Gyrus Plasmacision Laparoscopic SpatulaGyrus Medical, Inc. · 2004
  5. 1 generation backK080093 PKS Plasma Morcellator, Models 962000PK, 3620PKGyrus Acmi, Inc. · 2008
  6. This deviceK161038 PK MorcellatorGyrus Acmi, Inc. · 2016
Show all 10 generations
  1. Root · 10 generations backK936109 Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc. · 1994
  2. 9 generations backK960521 Sharplan Lasers, Inc. Silktouch Flash ScannerSharplan Lasers, Inc. · 1996
  3. 8 generations backK963339 Coherent Ultrapulse CO2 Surgical LasersCoherent Medical Group · 1997
  4. 7 generations backK974789 Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and LLumenis, Inc. · 1998
  5. 6 generations backK990947 Modified Versapulse Select Single Wavelength, HO: Yag and Dual…Lumenis, Inc. · 1999
  6. 5 generations backK011703 Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength…Lumenis · 2001 · Recalled
  7. 4 generations backK014290 Entec Plasma WandsArthrocare Corp. · 2002
  8. 3 generations backK021777 Gyrus Ent Cogent 2/G2 System (Generator,Accessories Somnoplasty…Gyrus Ent LLC · 2002
  9. 2 generations backK041633 Gyrus Plasmacision Laparoscopic SpatulaGyrus Medical, Inc. · 2004
  10. 1 generation backK080093 PKS Plasma Morcellator, Models 962000PK, 3620PKGyrus Acmi, Inc. · 2008
  11. This deviceK161038 PK MorcellatorGyrus Acmi, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K936109Sharplan Model 1120 CO2 Surgical LaserSharplan Lasers, Inc.1994—
−9K960521Sharplan Lasers, Inc. Silktouch Flash ScannerSharplan Lasers, Inc.1996—
−8K963339Coherent Ultrapulse CO2 Surgical LasersCoherent Medical Group1997—
−7K974789Coherent Ultrapulse S Series CO2 Surgical Lasers Model C and LLumenis, Inc.1998—
−6K990947Modified Versapulse Select Single Wavelength, HO: Yag and Dual Wavelength, HO…Lumenis, Inc.1999—
−5K011703Lumenis Versapulse Powersuite Holmium (HO:Yag) and Dual Wavelength…Lumenis20012
−4K014290Entec Plasma WandsArthrocare Corp.2002—
−3K021777Gyrus Ent Cogent 2/G2 System (Generator,Accessories Somnoplasty Electrodes and…Gyrus Ent LLC2002—
−2K041633Gyrus Plasmacision Laparoscopic SpatulaGyrus Medical, Inc.2004—
−1K080093PKS Plasma Morcellator, Models 962000PK, 3620PKGyrus Acmi, Inc.2008—
0 (this device)K161038PK MorcellatorGyrus Acmi, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
198610
198910
199010
199140
199230
199310
199440
199570
199680
199740
199860
199910
2000110
200130
200220
200320
FIG. 1 — Lineage of K161038, 1994–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEI device

  1. #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080093PKS Plasma Morcellator, Models 962000PK, 3620PK
Summary page 4
…Laparoscopic Power Morcellator Device name / Model Number PK Morcellator / WA90200A Predicate Device Gyrus ACMI PKS Plasma Morcellator K080093 No recalls reported for predicate device…
Gyrus Acmi, Inc.2008—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 8 companies; a new generation was cleared every 1.9 years on median.
  • 2 of the 70 ancestors have a recall of any class.

How does its category compare?

All GEI devices

GEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · GEI

52in 2025

2007: 502008: 612009: 422010: 462011: 352012: 392013: 482014: 492015: 472016: 642017: 522018: 472019: 482020: 592021: 462022: 552023: 652024: 592025: 522026 (partial year): 43
2007high 65 (2023) · low 35 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEI

113in 2025

2007: 51 days median2008: 71 days median2009: 130 days median2010: 109 days median2011: 135 days median2012: 133 days median2013: 136 days median2014: 103 days median2015: 123 days median2016: 108 days median2017: 72 days median2018: 93 days median2019: 93 days median2020: 105 days median2021: 146 days median2022: 150 days median2023: 104 days median2024: 125 days median2025: 113 days median2026 (partial year): 183 days median
2007high 183 (2026) · low 51 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEI

4in 2025

2007: 212008: 192009: 272010: 512011: 322012: 302013: 132014: 32015: 42016: 32017: 22018: 62019: 52020: 12021: 62022: 492023: 27, 4 Class I2024: 22, 10 Class I2025: 42026 (partial year): 8
2007high 51 (2010) · low 1 (2020)2026

Class I (14 since 2007) Class II/III not classified

Adverse event reports per year · GEI

7,592in 2025

2007: 2,7952008: 2,5562009: 3,5912010: 3,3772011: 4,4632012: 5,2162013: 4,8972014: 4,9082015: 4,9362016: 5,6162017: 6,0732018: 6,5452019: 7,0672020: 6,4902021: 6,3542022: 6,1032023: 7,1762024: 7,8972025: 7,592
2007high 7,897 (2024) · low 2,556 (2008)2025

MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075051212,795
20086171192,556
200942130273,591
201046109513,377
201135135324,463
201239133305,216
201348136134,897
20144910334,908
20154712344,936
20166410835,616
2017527226,073
2018479366,545
2019489357,067
20205910516,490
20214614666,354
202255150496,103
20236510427 (4)7,176
20245912522 (10)7,897
20255211347,592
2026431838—

What is it indicated for?

The PK Morcellator is intended for cutting, and extracting tissue in laparoscopic gynecologic procedures.

It is recommended to use the PK Morcellator in conjunction with the PneumoLiner containment device (WA90500US) for removal of uterine tissue.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161038: PK Morcellator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161038

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026