510(k) Report

510(k) · Cleared

Cleared

Dental Implants and Abutments

K161497510(k) TraditionalCleared Oct 28, 2016149-day reviewClass II21 CFR 872.3640

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ditron Precision, Ltd. · DZE Implant, Endosseous, Root-Form

Cleared on Oct 28, 2016 as substantially equivalent to K140728 (Ditron Precision, Ltd., 2014) and 1 other predicate after a 149-day review. Its family tree reaches back 15 generations to 1996. 1 later device descends from it.

Decided
Oct 28, 2016
Review
149 days
Class
Class II
Product code
DZE
Recalls
None
Predicates
2

Its longest line of descent runs back 15 generations to K960026 (1996). 203 ancestors in all, the oldest K820013 (1982). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 3 other ancestors2012: 1 other ancestor2007: 10 other ancestors2010: 2 other ancestors2008: 8 other ancestors2006: 11 other ancestors2004: 13 other ancestors2003: 12 other ancestors2002: 14 other ancestors2001: 12 other ancestors2000: 8 other ancestors2009: 5 other ancestors1999: 12 other ancestors1998: 7 other ancestors1997: 5 other ancestors1996: 13 other ancestors1995: 9 other ancestors1990: 3 other ancestors1988: 1 other ancestor2005: 5 other ancestors1994: 13 other ancestors1993: 12 other ancestors1989: 2 other ancestors1987: 1 other ancestor1992: 1 other ancestor1991: 3 other ancestors1984: 1 other ancestor1982: 1 other ancestor2024: 1 descendant clearedReference device: K131097 · LEGACY3 6MM Length Implants · Implant Direct Sybron Manufacturing, LLC · 2013K960026 · Biohorizons Dental Implant System · BioHorizons Implant Systems, Inc. · 1996K964330 · Biohorizons Dental Implant System (Name Subject to Change) · BioHorizons Implant Systems, Inc. · 1997K972313 · The Maestro System · BioHorizons Implant Systems, Inc. · 1997×3: 3 generations cleared close together, K020133 (2002), K020645 (2002), K022795 (2002) K030463 · Modification to the Maestro System · BioHorizons Implant Systems, Inc. · 2003 · recalledK032351 · The Maestro System 3.0MM Diameter Implant · BioHorizons Implant Systems, Inc. · 2003K041938 · Maximus OS (Overdenture System) · BioHorizons Implant Systems, Inc. · 2004 · recalledK052419 · Maximus 3.0 and OS Implants · BioHorizons Implant Systems, Inc. · 2005×2: 2 generations cleared close together, K093321 (2010), K100985 (2010) ×2: 2 generations cleared close together, K103691 (2011), K112440 (2012) K140728 · Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision Implant, Opi - One Piece Implant, Dental Abutments and PR · Ditron Precision, Ltd. · 201419801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 18 other ancestors4 generations back: 42 other ancestors5 generations back: 36 other ancestors6 generations back: 26 other ancestors7 generations back: 20 other ancestors8 generations back: 28 other ancestors9 generations back: 10 other ancestors10 generations back: 3 other ancestors11 generations back: 1 other ancestor 1 generation forward: 1 descendant K140728 · Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision Implant, Opi - One Piece Implant, Dental Abutments and PR · Ditron Precision, Ltd. · 2014K112440 · AB Dental Devices Implants and Accessories · A.B. Dental Devices, Ltd. · 2012K103691 · Biohorizons Abutments for Zimmer · BioHorizons Implant Systems, Inc. · 2011 · recalledK100985 · Biohorizons Simple Solutions with Laser-Lok · BioHorizons Implant Systems, Inc. · 2010K093321 · Biohorizons Laser-Lok 3.0 Implant System · BioHorizons Implant Systems, Inc. · 2010 · recalledK052419 · Maximus 3.0 and OS Implants · BioHorizons Implant Systems, Inc. · 2005K041938 · Maximus OS (Overdenture System) · BioHorizons Implant Systems, Inc. · 2004 · recalledK032351 · The Maestro System 3.0MM Diameter Implant · BioHorizons Implant Systems, Inc. · 2003K030463 · Modification to the Maestro System · BioHorizons Implant Systems, Inc. · 2003 · recalledK022795 · Modification to the Maestro System · BioHorizons Implant Systems, Inc. · 2002K020645 · Modification to the Maestro System · BioHorizons Implant Systems, Inc. · 2002K020133 · Modification to the Maestro System · BioHorizons Implant Systems, Inc. · 2002K972313 · The Maestro System · BioHorizons Implant Systems, Inc. · 1997K964330 · Biohorizons Dental Implant System (Name Subject to Change) · BioHorizons Implant Systems, Inc. · 1997K960026 · Biohorizons Dental Implant System · BioHorizons Implant Systems, Inc. · 1996−15−10−50
  1. Root · 15 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
  2. 11 generations between
  3. 3 generations backK103691 Biohorizons Abutments for ZimmerBioHorizons Implant Systems, Inc. · 2011 · Recalled
  4. 2 generations backK112440 AB Dental Devices Implants and AccessoriesA.B. Dental Devices, Ltd. · 2012
  5. 1 generation backK140728 Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision…Ditron Precision, Ltd. · 2014
  6. This deviceK161497 Dental Implants and AbutmentsDitron Precision, Ltd. · 2016
  7. Descendant · cites it directly · 0 of its ownK233231 Dental Implants and AbutmentsDitron Dental, Ltd. · 2024
Show all 15 generations
  1. Root · 15 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
  2. 14 generations backK964330 Biohorizons Dental Implant System (Name Subject to Change)BioHorizons Implant Systems, Inc. · 1997
  3. 13 generations backK972313 The Maestro SystemBioHorizons Implant Systems, Inc. · 1997
  4. 12 generations backK020133 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
  5. 11 generations backK020645 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
  6. 10 generations backK022795 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
  7. 9 generations backK030463 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2003 · Recalled
  8. 8 generations backK032351 The Maestro System 3.0MM Diameter ImplantBioHorizons Implant Systems, Inc. · 2003
  9. 7 generations backK041938 Maximus OS (Overdenture System)BioHorizons Implant Systems, Inc. · 2004 · Recalled
  10. 6 generations backK052419 Maximus 3.0 and OS ImplantsBioHorizons Implant Systems, Inc. · 2005
  11. 5 generations backK093321 Biohorizons Laser-Lok 3.0 Implant SystemBioHorizons Implant Systems, Inc. · 2010 · Recalled
  12. 4 generations backK100985 Biohorizons Simple Solutions with Laser-LokBioHorizons Implant Systems, Inc. · 2010
  13. 3 generations backK103691 Biohorizons Abutments for ZimmerBioHorizons Implant Systems, Inc. · 2011 · Recalled
  14. 2 generations backK112440 AB Dental Devices Implants and AccessoriesA.B. Dental Devices, Ltd. · 2012
  15. 1 generation backK140728 Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision…Ditron Precision, Ltd. · 2014
  16. This deviceK161497 Dental Implants and AbutmentsDitron Precision, Ltd. · 2016

Most influential descendants

Showing 1 of 1 · See all
  • K233231Dental Implants and AbutmentsDitron Dental, Ltd. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−15K960026Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc.1996—
−14K964330Biohorizons Dental Implant System (Name Subject to Change)BioHorizons Implant Systems, Inc.1997—
−13K972313The Maestro SystemBioHorizons Implant Systems, Inc.1997—
−12K020133Modification to the Maestro SystemBioHorizons Implant Systems, Inc.2002—
−11K020645Modification to the Maestro SystemBioHorizons Implant Systems, Inc.2002—
−10K022795Modification to the Maestro SystemBioHorizons Implant Systems, Inc.2002—
−9K030463Modification to the Maestro SystemBioHorizons Implant Systems, Inc.20031
−8K032351The Maestro System 3.0MM Diameter ImplantBioHorizons Implant Systems, Inc.2003—
−7K041938Maximus OS (Overdenture System)BioHorizons Implant Systems, Inc.20042
−6K052419Maximus 3.0 and OS ImplantsBioHorizons Implant Systems, Inc.2005—
−5K093321Biohorizons Laser-Lok 3.0 Implant SystemBioHorizons Implant Systems, Inc.20101
−4K100985Biohorizons Simple Solutions with Laser-LokBioHorizons Implant Systems, Inc.2010—
−3K103691Biohorizons Abutments for ZimmerBioHorizons Implant Systems, Inc.20111
−2K112440AB Dental Devices Implants and AccessoriesA.B. Dental Devices, Ltd.2012—
−1K140728Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision Implant, Opi -…Ditron Precision, Ltd.2014—
0 (this device)K161497Dental Implants and AbutmentsDitron Precision, Ltd.2016—
+1K233231Dental Implants and AbutmentsDitron Dental, Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198410
198710
198810
198920
199030
199130
199210
1993120
1994130
199590
1996130
199750
199870
1999120
200080
2001120
2002140
2003120
2004130
200550
2006110
2007100
200880
200950
201020
201130
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K161497, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DZE device

  1. #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140728Mpi - Molecular Precision Implant, Cpi - Cylindrical Precision Implant, Opi - One Piece…
Summary page 5
…nt to the following predicate devices:  Ditron Precision Ltd's legally marketed Dental Implants and Abutments, cleared under 510(k) number K140728 (primary predicate device), and;  MIS Implants Technologies Ltd's MIS Short Implants (SEVEN), cleared under…
Ditron Precision, Ltd.2014—
*K103089Seven Implants; Biocom Implants; Lance Implants
Summary page 5
…510(k) number K140728 (primary predicate device), and;  MIS Implants Technologies Ltd's MIS Short Implants (SEVEN), cleared under 510(k) number K103089 (reference predicate device).  Implant Direct LLC's Legacy3 6mm Length implants, cleared under 510(k) number…
Mis - Implant Technologies, Ltd.2011—
†K131097LEGACY3 6MM Length ImplantsImplant Direct Sybron Manufacturing, LLC2013—

Also cleared against K140728: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233231Dental Implants and AbutmentsDitron Dental, Ltd.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 9 months on median.
  • 27 of the 203 ancestors have a recall of any class.
  • Of its descendants, K233231 (Ditron Dental, Ltd., 2024) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K140728.

How does its category compare?

All DZE devices

DZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DZE

31in 2025

2007: 432008: 612009: 412010: 342011: 262012: 392013: 422014: 362015: 362016: 402017: 482018: 412019: 312020: 412021: 342022: 342023: 352024: 402025: 312026 (partial year): 15
2007high 61 (2008) · low 26 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DZE

184in 2025

2007: 107 days median2008: 118 days median2009: 110 days median2010: 162 days median2011: 194 days median2012: 174 days median2013: 195 days median2014: 265 days median2015: 215 days median2016: 219 days median2017: 223 days median2018: 200 days median2019: 231 days median2020: 230 days median2021: 182 days median2022: 243 days median2023: 248 days median2024: 222 days median2025: 184 days median2026 (partial year): 194 days median
2007high 265 (2014) · low 107 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DZE

1in 2025

2007: 112008: 42009: 32010: 32012: 112013: 12014: 72015: 32016: 152017: 42018: 42019: 82021: 62024: 12025: 12026 (partial year): 2
2007high 15 (2016) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DZE

465,788in 2025

2007: 2252008: 3932009: 1642010: 3602011: 3622012: 3582013: 3912014: 1,1242015: 2,8942016: 1,1162017: 9,7192018: 12,8922019: 167,0162020: 255,5242021: 479,6182022: 483,2242023: 537,5852024: 473,6292025: 465,788
2007high 537,585 (2023) · low 164 (2009)2025

MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074310711225
2008611184393
2009411103164
2010341623360
2011261940362
20123917411358
2013421951391
20143626571,124
20153621532,894
201640219151,116
20174822349,719
201841200412,892
2019312318167,016
2020412300255,524
2021341826479,618
2022342430483,224
2023352480537,585
2024402221473,629
2025311841465,788
2026151942—

What is it indicated for?

Ditron's Dental Implants and Abutments are indicated for use in surgical and restorative applications for placement in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, in order to restore the patient’s chewing function. » Two stage: MPI, ULT, API and CPI models * One stage: OPI model The 3.3 and 3.0 mm diameter models for One stage OPI, Two stage MPI, Two stage and API implants are intended only for…

Read the full statement (244 words)

Ditron's Dental Implants and Abutments are indicated for use in surgical and restorative applications for placement in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, in order to restore the patient’s chewing function.

» Two stage: MPI, ULT, API and CPI models

* One stage: OPI model

The 3.3 and 3.0 mm diameter models for One stage OPI, Two stage MPI, Two stage and API implants are intended only for the incisors and cuspids of the maxilla and mandible. They are also indicated for denture stabilization using multiple implants.

Two stage and One stage implants for temporary or long-term use: MPI, ULT, API, CPI, OPI are self-tapping titanium threaded screws indicated for long term intra bony applications. They permit immediate splint stability and long-term fixation of new or existing crown, bridge and prosthesis and protection of graft sites.

MPI, ULT, API, CPI and OPI designs are indicated for immediate loading (except for MPI and API in 6mm length) when good primary stability is achieved and with appropriate occlusal loading.

MPI, ULT, API, CPI and OPI are indicated for immediate loading (except for MPI and API in 6mm length) in single tooth restorations when good primary stability is achieved with appropriate occlusal loading.

The 30-degree multi-unit abutments must be used within 45 degrees of parallelism for a splinted restoration. The 17-degree multi-unit abutments must be used within 32 degrees of parallelism for a splinted restoration.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K161497: Dental Implants and Abutments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K161497

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026