510(k) Report

510(k) · Cleared

Recalled · Class II · 2017

EasyOne Pro Respiratory Analysis System

K161534510(k) TraditionalCleared Feb 22, 2017264-day reviewClass II21 CFR 868.1890Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ndd Medizintechnik AG · BTY Calculator, Predicted Values, Pulmonary Function

Cleared on Feb 22, 2017 as substantially equivalent to K091428 (Ndd Medizitechnik AG, 2010) and 1 other predicate after a 264-day review. Its family tree reaches back 2 generations to 1994. 2 later devices descend from it. It has been recalled 2 times.

Decided
Feb 22, 2017
Review
264 days
Class
Class II
Product code
BTY
Recalls
2
Predicates
2

Its longest line of descent runs back 2 generations to K942211 (1994). 3 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2012: 1 other ancestor2022: 1 descendant cleared2023: 1 descendant clearedK942211 · VMAX229 Series Pulmonary/Metabolic Systems · Sensor Medics Corp. · 1994K091428 · Easyone Pro Respiratory Analysis System · Ndd Medizitechnik AG · 20101990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K091428 · Easyone Pro Respiratory Analysis System · Ndd Medizitechnik AG · 2010K942211 · VMAX229 Series Pulmonary/Metabolic Systems · Sensor Medics Corp. · 19940
  1. Root · 2 generations backK942211 VMAX229 Series Pulmonary/Metabolic SystemsSensor Medics Corp. · 1994
  2. 1 generation backK091428 Easyone Pro Respiratory Analysis SystemNdd Medizitechnik AG · 2010
  3. This deviceK161534 EasyOne Pro Respiratory Analysis SystemNdd Medizintechnik AG · 2017
  4. Descendant · cites it directly · 1 of its ownK221030 Model 9100 PFT/DICOVitalograph Ireland, Ltd. · 2022
  5. Descendant · 2 generations on · 0 of its ownK223818 Model 9160 VitaloQUBVitalograph Ireland, Ltd. · 2023

Most influential descendants

Showing 2 of 2 · See all
  • K221030Model 9100 PFT/DICOVitalograph Ireland, Ltd. · 2022 · cites it directly1descendant
  • K223818Model 9160 VitaloQUBVitalograph Ireland, Ltd. · 2023 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K942211VMAX229 Series Pulmonary/Metabolic SystemsSensor Medics Corp.1994—
−1K091428Easyone Pro Respiratory Analysis SystemNdd Medizitechnik AG2010—
0 (this device)K161534EasyOne Pro Respiratory Analysis SystemNdd Medizintechnik AG2017—
+1K221030Model 9100 PFT/DICOVitalograph Ireland, Ltd.2022—
+2K223818Model 9160 VitaloQUBVitalograph Ireland, Ltd.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202310
FIG. 1 — Lineage of K161534, 1994–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BTY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTY device

  1. #1 K260242 CPETWise Platformscore 13.1 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091428Easyone Pro Respiratory Analysis System
Summary page 4
…ator Product code: BTY Regulation number: 868.1890 Predicate Device Primary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro K091428 Secondary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro LAB K120635 Device Description The EasyOne Pro R…
Ndd Medizitechnik AG2010—
*K120635Easyone Pro Respiratory Testing Device
Summary page 4
…Primary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro K091428 Secondary Predicate: EasyOne Pro Respiratory Analysis System, model EasyOne Pro LAB K120635 Device Description The EasyOne Pro Respiratory Analysis System consists of two different device models: EasyOne Pro and EasyOne…
Ndd Medizitechnik AG2012—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K221030Model 9100 PFT/DICOVitalograph Ireland, Ltd.20221

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 15, 2017Class IIZ-0596-2020Component change controlThe CO/CO2 sensor cable harness may have lower electromagnetic shielding, which might have resulted in a non-compliance with the IEC 60601-1-2 standard. As a consequence of a lower electromagnetic shielding provided by the cable harness…
Aug 15, 2017Class IIZ-0597-2020Component change controlThe CO/CO2 sensor cable harness may have lower electromagnetic shielding, which might have resulted in a non-compliance with the IEC 60601-1-2 standard. As a consequence of a lower electromagnetic shielding provided by the cable harness…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 3 companies; a new generation was cleared every 15.2 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K221030 (Vitalograph Ireland, Ltd., 2022) has gone furthest, with 1 descendant of its own.

How does its category compare?

All BTY devices

BTY Calculator, Predicted Values, Pulmonary Function: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · BTY

3in 2024

2007: 22008: 32009: 12010: 12011: 12012: 32016: 12017: 12019: 22020: 12021: 12022: 12023: 12024: 32026 (partial year): 1
2007high 3 (2008) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTY

266in 2024

2008: 104 days median2012: 139 days median2024: 266 days median
2007high 266 (2024) · low 104 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTY

2in 2017

2014: 12017: 2
2007high 2 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BTY

5in 2024

2009: 12011: 32012: 22014: 12015: 512016: 242017: 92018: 52019: 32020: 32021: 22022: 22023: 12024: 5
2007high 51 (2015) · low 0 (2007)2025

MAUDE reports naming product code BTY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
2008310400
20091—01
20101—00
20111—03
2012313902
20130—00
20140—11
20150—051
20161—024
20171—29
20180—05
20192—03
20201—03
20211—02
20221—02
20231—01
2024326605
20250—00
20261—0—

What is it indicated for?

EasyOne Pro/LAB is designed for conducting lung function measurements in general or specialist practices or in hospitals.

EasyOne Pro/LAB can also be used in clinical settings in occupational medicine for performing lung function screenings or measurements.

EasyOne Pro/LAB is used to conduct lung function measurements on adults and children starting at age 4, except measurements of diffusing capacity of the lung based on CO (DLCO), which can be performed on adults and children starting at age 6.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161534: EasyOne Pro Respiratory Analysis System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161534

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026