Theia NPWT Foam Wound Dressing Kit-Small, Theia NPWT Foam Wound Dressing Kit-Medium, Theia NPWT Foam Wound Dressing Kit-Large

K161570510(k) TraditionalCleared Aug 29, 201683-day reviewClass II21 CFR 878.4780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lc Medical Concepts, Inc. · OMP Negative Pressure Wound Therapy Powered Suction Pump

Cleared on Aug 29, 2016 as substantially equivalent to K133333 (Blue Ocean Medical Product, LLC, 2014) after an 83-day review. Its family tree reaches back 7 generations to 1995. 2 later devices descend from it.

Decided
Aug 29, 2016
Review
83 days
Class
Class II
Product code
OMP
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K945062 (1995). 10 ancestors in all. 2 later devices descend from it, 1 citing it directly.

  1. Root · 7 generations backK945062 VacplusKinetic Concepts, Inc. · 1995
  2. 6 generations backK042134 Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2004 · Recalled
  3. 5 generations backK052456 Modification to Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2005
  4. 4 generations backK061919 Versatile 1 Ezcare Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2007 · Recalled
  5. 3 generations backK082211 Renasys-F Negative Pressure Wound Therapy Foam Dressing KitsSmith & Nephew, Inc. · 2008 · Recalled
  6. 2 generations backK092992 A4-XLR8 Foam DressingGenadyne Biotechnologies, Inc. · 2010
  7. 1 generation backK133333 Uni NPWT Foam Dressing Kit, Uni NPWT Foam Dressing Kit, Uni NPWT…Blue Ocean Medical Product, LLC · 2014
  8. This deviceK161570 Theia NPWT Foam Wound Dressing Kit-Small, Theia NPWT Foam Wound…Lc Medical Concepts, Inc. · 2016
  9. Descendant · cites it directly · 1 of its ownK211277 Theia NPWT Foam Wound Dressing KitClear Choice Therapeutics, Inc. · 2021
  10. Descendant · 2 generations on · 0 of its ownK232379 PREVENT KitClear Choice Therapeutics · 2024

Most influential descendants

Showing 2 of 2 · See all
  • K211277Theia NPWT Foam Wound Dressing KitClear Choice Therapeutics, Inc. · 2021 · cites it directly1descendant
  • K232379PREVENT KitClear Choice Therapeutics · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K945062VacplusKinetic Concepts, Inc.1995—
−6K042134Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated20042
−5K052456Modification to Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated2005—
−4K061919Versatile 1 Ezcare Wound Vacuum SystemBlue Sky Medical Group Incorporated20071
−3K082211Renasys-F Negative Pressure Wound Therapy Foam Dressing KitsSmith & Nephew, Inc.20081
−2K092992A4-XLR8 Foam DressingGenadyne Biotechnologies, Inc.2010—
−1K133333Uni NPWT Foam Dressing Kit, Uni NPWT Foam Dressing Kit, Uni NPWT Foam Dressing…Blue Ocean Medical Product, LLC2014—
0 (this device)K161570Theia NPWT Foam Wound Dressing Kit-Small, Theia NPWT Foam Wound Dressing…Lc Medical Concepts, Inc.2016—
+1K211277Theia NPWT Foam Wound Dressing KitClear Choice Therapeutics, Inc.2021—
+2K232379PREVENT KitClear Choice Therapeutics2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
202410
FIG. 1 — Lineage of K161570, 1995–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OMP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OMP device

  1. #1 K260646 Renasys Edge (66803126)score 15.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133333Uni NPWT Foam Dressing Kit, Uni NPWT Foam Dressing Kit, Uni NPWT Foam Dressing Kit
Summary page 4
…OMP – Pump, Portable, Aspiration (manual or powered) Panel: General & Plastic Surgery Predicate Device: UNI NPWT Foam Dressing Kit (K133333) Indications For Use: The Theia NPWT Foam Dressing Kit is intended to be used in conjunction with the Simex Negative Pressure W…
Blue Ocean Medical Product, LLC2014—

Also cleared against K133333: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K211277Theia NPWT Foam Wound Dressing KitClear Choice Therapeutics, Inc.20211

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 1.7 years on median.
  • 3 of the 10 ancestors have a recall of any class.
  • Of its descendants, K211277 (Clear Choice Therapeutics, Inc., 2021) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K133333.

How does its category compare?

All OMP devices

OMP Negative Pressure Wound Therapy Powered Suction Pump: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · OMP

5in 2025

2007: 62008: 82009: 82010: 62011: 62012: 112013: 112014: 102015: 202016: 192017: 112018: 132019: 152020: 62021: 92022: 102023: 82024: 92025: 52026 (partial year): 9
2007high 20 (2015) · low 5 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OMP

127in 2025

2007: 113 days median2008: 98 days median2009: 87 days median2010: 97 days median2011: 123 days median2012: 292 days median2013: 84 days median2014: 179 days median2015: 189 days median2016: 146 days median2017: 137 days median2018: 214 days median2019: 249 days median2020: 179 days median2021: 238 days median2022: 229 days median2023: 291 days median2024: 181 days median2025: 127 days median2026 (partial year): 141 days median
2007high 292 (2012) · low 84 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OMP

2in 2024

2009: 72010: 32012: 12013: 22014: 42015: 12016: 22019: 12024: 2
2007high 7 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OMP

140in 2025

2007: 12008: 12009: 792010: 802011: 1302012: 972013: 1692014: 2292015: 3782016: 3982017: 3682018: 4222019: 9942020: 3,6642021: 1,4222022: 2582023: 1432024: 1352025: 140
2007high 3,664 (2020) · low 1 (2007)2025

MAUDE reports naming product code OMP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611301
200889801
2009887779
2010697380
201161230130
201211292197
201311842169
2014101794229
2015201891378
2016191462398
2017111370368
2018132140422
2019152491994
2020617903,664
2021923801,422
2022102290258
202382910143
202491812135
202551270140
202691410—

What is it indicated for?

The Theia NPWT Foam Wound Dressing Kit is intended to be used in conjunction with the Simex Negative Pressure Wound Therapy Pumps (K113291) for the application of negative pressure wound therapy to the wound. When used in conjunction with the Simex Negative Pressure Wound Therapy Pumps, the Theia NPWT Foam Wound Dressing Kit is indicated for patients who would benefit from a suction device, particularly as the device may promote wound healing by removal…

Read the full statement (121 words)

The Theia NPWT Foam Wound Dressing Kit is intended to be used in conjunction with the Simex Negative Pressure Wound Therapy Pumps (K113291) for the application of negative pressure wound therapy to the wound. When used in conjunction with the Simex Negative Pressure Wound Therapy Pumps, the Theia NPWT Foam Wound Dressing Kit is indicated for patients who would benefit from a suction device, particularly as the device may promote wound healing by removal of excess exudates, infectious material and tissue debris.

The Theia NPWT Foam Wound Dressing Kit is appropriate for use on the following wounds;

• Pressure Ulcers

• Diabetic/Neuropathic Ulcers

• Venous Insufficiency Ulcers

• Traumatic Wounds

• Post-Operative and Dehisced Surgical Wounds

• Skin Flap and Grafts

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161570: Theia NPWT Foam Wound Dressing Kit-Small, Theia NPWT Foam Wound Dressing Kit-Medium, Theia NPWT Foam Wound Dressing Kit-Large.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161570

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026