510(k) Report

510(k) · Cleared

Cleared

SoundStar eco 8F 3D Diagnostic eco Ultrasound Catheters, SoundStar eco 8F G 3D Diagnostic eco Ultrasound Catheters

K161700510(k) TraditionalCleared Nov 21, 2016154-day reviewClass II21 CFR 870.1200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sterilmed, Inc. · OWQ Reprocessed Intravascular Ultrasound Catheter

Cleared on Nov 21, 2016 as substantially equivalent to K140318 (Biosense Webster, 2014) and 1 other predicate after a 154-day review. Its family tree reaches back 5 generations to 1992.

Decided
Nov 21, 2016
Review
154 days
Class
Class II
Product code
OWQ
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K921148 (1992). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK921148 Cvis Insight Catheters for Intracardiac UseCardiovascular Imaging Systems, Inc. · 1992
  2. 4 generations backK992631 Acunav Diagnostic Ultrasound CatheterAcuson Corp. · 1999 · Recalled
  3. 3 generations backK033650 Acunav 90/10 Diagnostic Ultrasound CatheterSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  4. 2 generations backK070242 Soundstar 3D Ultrasound Catheter, Model M-5723-05Biosense Webster, Inc. · 2007
  5. 1 generation backK110076 Reprocessed 3D Diagnostic Ultrasound CatheterSterilmed, Inc. · 2011 · Recalled
  6. This deviceK161700 SoundStar eco 8F 3D Diagnostic eco Ultrasound Catheters, SoundStar…Sterilmed, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K921148Cvis Insight Catheters for Intracardiac UseCardiovascular Imaging Systems, Inc.1992—
−4K992631Acunav Diagnostic Ultrasound CatheterAcuson Corp.19991
−3K033650Acunav 90/10 Diagnostic Ultrasound CatheterSiemens Medical Solutions USA, Inc.20041
−2K070242Soundstar 3D Ultrasound Catheter, Model M-5723-05Biosense Webster, Inc.2007—
−1K110076Reprocessed 3D Diagnostic Ultrasound CatheterSterilmed, Inc.20111
0 (this device)K161700SoundStar eco 8F 3D Diagnostic eco Ultrasound Catheters, SoundStar eco 8F G 3D…Sterilmed, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199710
201410
FIG. 1 — Lineage of K161700, 1992–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWQ device

  1. #1 K254149 Reprocessed AcuNav CRYSTAL™ Ultrasound…score 13.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140318Soundstar Eco 8F Gultrasound Catheter, Soundstar Eco 8F Ultrasound Catheter
Summary page 5
…OWQ Predicate Biosense Webster, Inc.: SoundStar eco 8F G Ultrasound Catheter, and SoundStar Device: eco 8F Ultrasound Catheter (510(k) K140318) Secondary / Sterilmed Inc: Reprocessed 3D Ultrasound Diagnostic Catheter (510(k) K110076) Reference Sterilmed Inc:…
Biosense Webster20141
*K110076Reprocessed 3D Diagnostic Ultrasound Catheter
Summary page 5
…heter, and SoundStar Device: eco 8F Ultrasound Catheter (510(k) K140318) Secondary / Sterilmed Inc: Reprocessed 3D Ultrasound Diagnostic Catheter (510(k) K110076) Reference Sterilmed Inc: Reprocessed Ivus Imaging Catheter (510(k) K043453) Predicates Device Sterilmed Repro…
Sterilmed, Inc.20111
†K043453Sterilemed Reprocessed Ivus Imaging CatheterSterilmed, Inc.20053

Also cleared against K140318: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 5 companies; a new generation was cleared every 4.3 years on median.
  • 4 of the 8 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K140318.

How does its category compare?

All OWQ devices

OWQ Reprocessed Intravascular Ultrasound Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · OWQ

3in 2025

2007: 12009: 12011: 12012: 12016: 22017: 22018: 12019: 32020: 12022: 22023: 82024: 12025: 32026 (partial year): 1
2007high 8 (2023) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWQ

100in 2025

2019: 261 days median2023: 78 days median2025: 100 days median
2007high 261 (2019) · low 78 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWQ

2in 2025

2014: 12025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWQ

42in 2025

2013: 42014: 22015: 62016: 52017: 22018: 22019: 92020: 292021: 382022: 242023: 292024: 372025: 42
2007high 42 (2025) · low 0 (2007)2025

MAUDE reports naming product code OWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20091—00
20100—00
20111—00
20121—00
20130—04
20140—12
20150—06
20162—05
20172—02
20181—02
2019326109
20201—029
20210—038
20222—024
2023878029
20241—037
20253100242
20261—0—

What is it indicated for?

The Reprocessed 3D Diagnostic Ultrasound eco Catheters are indicated for intra-cardiac and intra-luminal visualization of cardiac and great vessel anatomy and physiology as well as visualization of other devices in the heart. When used with compatible Carto® 3 EP Navigation Systems (version 2.3 and higher) the reprocessed 3D Diagnostic Ultrasound eco Catheters provide location information.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161700: SoundStar eco 8F 3D Diagnostic eco Ultrasound Catheters, SoundStar eco 8F G 3D Diagnostic eco Ultrasound Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161700

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026