510(k) Report

510(k) · Cleared

Cleared

Fully Automatic Electronic Blood Pressure Monitor

K162230510(k) AbbreviatedCleared Nov 18, 2016102-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Adon Health Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on Nov 18, 2016 as substantially equivalent to K102906 (Andon Health Co, Ltd., 2010) after a 102-day review. Its family tree reaches back 1 generation to 2010. 6 later devices descend from it.

Decided
Nov 18, 2016
Review
102 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K102906 (2010). 6 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2019: 1 descendant cleared2021: 1 descendant cleared2023: 2 descendants cleared2024: 1 descendant cleared2025: 1 descendant clearedK102906 · Fully Automatic Electronic Blood Pressure Monitor · Andon Health Co, Ltd. · 20102010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 3 descendants4 generations forward: 1 descendant K102906 · Fully Automatic Electronic Blood Pressure Monitor · Andon Health Co, Ltd. · 20100
  1. Root · 1 generation backK102906 Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd. · 2010
  2. This deviceK162230 Fully Automatic Electronic Blood Pressure MonitorAdon Health Co., Ltd. · 2016
  3. Descendant · cites it directly · 5 of its ownK183534 Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd. · 2019
  4. Descendant · 2 generations on · 4 of its ownK210770 Arm Blood Pressure Monitor, Wireless Blood Pressure MonitorAndon Health Co, Ltd. · 2021
  5. Descendant · 3 generations on · 1 of its ownK234041 Fully Automatic Electronic Blood Pressure Monitor (KD-5811VA); Fully…Andon Health Co, Ltd. · 2024
  6. Descendant · 4 generations on · 0 of its ownK251113 iHealth Compare Wireless Blood Pressure Monitor (BP-300C);iHealth…Andon Health Co, Ltd. · 2025
  7. Descendant · 3 generations on · 0 of its ownK222887 Arm Blood Pressure Monitor/Automatic Wireless Smart Blood Pressure…Famidoc Technology Company Limited · 2023

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2019: 12021: 12023: 22024: 12025: 1
2019high 2 (2023) · low 0 (2020)2026

Most influential descendants

Showing 5 of 6 · See all
  • K183534Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd. · 2019 · cites it directly5descendants
  • K210770Arm Blood Pressure Monitor, Wireless Blood Pressure MonitorAndon Health Co, Ltd. · 2021 · 2 generations on4descendants
  • K234041Fully Automatic Electronic Blood Pressure Monitor (KD-5811VA); Fully Automatic…Andon Health Co, Ltd. · 2024 · 3 generations on1descendant
  • K251113iHealth Compare Wireless Blood Pressure Monitor (BP-300C);iHealth Compare Pro Wireless…Andon Health Co, Ltd. · 2025 · 4 generations on0descendants
  • K222887Arm Blood Pressure Monitor/Automatic Wireless Smart Blood Pressure MonitorFamidoc Technology Company Limited · 2023 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K102906Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd.2010—
0 (this device)K162230Fully Automatic Electronic Blood Pressure MonitorAdon Health Co., Ltd.2016—
+1K183534Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd.2019—
+2K210770Arm Blood Pressure Monitor, Wireless Blood Pressure MonitorAndon Health Co, Ltd.2021—
+3K234041Fully Automatic Electronic Blood Pressure Monitor (KD-5811VA); Fully Automatic…Andon Health Co, Ltd.2024—
+4K251113iHealth Compare Wireless Blood Pressure Monitor (BP-300C);iHealth Compare Pro…Andon Health Co, Ltd.2025—
+3K222887Arm Blood Pressure Monitor/Automatic Wireless Smart Blood Pressure MonitorFamidoc Technology Company Limited2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202110
202320
202410
202510
FIG. 1 — Lineage of K162230, 2010–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102906Fully Automatic Electronic Blood Pressure Monitor
Summary page 4
…diovascular 4.0 Predicate device information Manufacturer: Andon Health Co., Ltd. Device: KD-5964 Fully Automatic Electronic Blood Pressure Monitor 510(k) number: K102906 K162230 Page 1 of 3 KD-5920, 5920L an…
Andon Health Co, Ltd.2010—

Also cleared against K102906: 4 other devices →

What descends from it? (6)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K183534Fully Automatic Electronic Blood Pressure MonitorAndon Health Co, Ltd.20195

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K183534 (Andon Health Co, Ltd., 2019) has gone furthest, with 5 descendants of its own.
  • 4 other devices also cite its predicate K102906.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

KD-5920, KD-5920L and KD-5923 Fully Automatic Electronic Blood Pressure Monitor is for use by medical professionals or at home and is a non-invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an adult individual by using a non-invasive technique in which an inflatable cuff is wrapped around the upper arm. The cuff circumference is limited to 22cm-48cm.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K162230: Fully Automatic Electronic Blood Pressure Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K162230

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026