510(k) Report

510(k) · Cleared

Cleared

Enobio Wireless EEG

K162681510(k) TraditionalCleared Jun 2, 2017249-day reviewClass II21 CFR 882.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neuroelectrics Barcelona S.L.U. · GWQ Full-Montage Standard Electroencephalograph

Cleared on Jun 2, 2017 as substantially equivalent to K103140 (Carefusion 209, Inc., 2011) after a 249-day review. Its family tree reaches back 5 generations to 2000. 1 later device descends from it.

Decided
Jun 2, 2017
Review
249 days
Class
Class II
Product code
GWQ
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K001564 (2000). 14 ancestors in all, the oldest K964280 (1997). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 2 other ancestors2004: 2 other ancestors2000: 1 other ancestor2005: 1 other ancestor2001: 1 other ancestor1999: 1 other ancestor1997: 1 other ancestor2026: 1 descendant clearedK001564 · Scan LT40 (40 Channels) · Neuro Scan Labs · 2000K023536 · Nuamps · Neuroscan · 2003K060803 · G.Usbamp · G.Tec Medical Engineering GmbH · 2006K090957 · Blackrock Neuroport Biopotential Signal Processing System · I2s Micro Implantable Systems, LLC · 2009 · recalledK103140 · Nicolet Wireless Eeg · Carefusion 209, Inc. · 2011 · recalled1995200020052010201520202025
  1. Root · 5 generations backK001564 Scan LT40 (40 Channels)Neuro Scan Labs · 2000
  2. 4 generations backK023536 NuampsNeuroscan · 2003
  3. 3 generations backK060803 G.UsbampG.Tec Medical Engineering GmbH · 2006
  4. 2 generations backK090957 Blackrock Neuroport Biopotential Signal Processing SystemI2s Micro Implantable Systems, LLC · 2009 · Recalled
  5. 1 generation backK103140 Nicolet Wireless EegCarefusion 209, Inc. · 2011 · Recalled
  6. This deviceK162681 Enobio Wireless EEGNeuroelectrics Barcelona S.L.U. · 2017
  7. Descendant · cites it directly · 0 of its ownK261604 Enobio Dx (Enobio Dx 8);Enobio Dx (Enobio Dx 20);Enobio Dx (Enobio…Neuroelectrics Barcelona S.L.U. · 2026

Most influential descendants

Showing 1 of 1 · See all
  • K261604Enobio Dx (Enobio Dx 8);Enobio Dx (Enobio Dx 20);Enobio Dx (Enobio Dx 32)Neuroelectrics Barcelona S.L.U. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K001564Scan LT40 (40 Channels)Neuro Scan Labs2000—
−4K023536NuampsNeuroscan2003—
−3K060803G.UsbampG.Tec Medical Engineering GmbH2006—
−2K090957Blackrock Neuroport Biopotential Signal Processing SystemI2s Micro Implantable Systems, LLC20092
−1K103140Nicolet Wireless EegCarefusion 209, Inc.20111
0 (this device)K162681Enobio Wireless EEGNeuroelectrics Barcelona S.L.U.2017—
+1K261604Enobio Dx (Enobio Dx 8);Enobio Dx (Enobio Dx 20);Enobio Dx (Enobio Dx 32)Neuroelectrics Barcelona S.L.U.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
199910
200010
200110
200420
200510
200620

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202610
FIG. 1 — Lineage of K162681, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWQ device

  1. #1 K260455 New Wave Systemscore 13.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K103140Nicolet Wireless Eeg
Summary page 5
…Code Regulation Sponsor Nicolet Wireless 21 CFR 882.1835 & Carefusion 209, Inc. K103140 GWL & GWQ EEG 21 CFR 882.1400 6. Indication for Use Statement ENOBIO is…
Carefusion 209, Inc.20111

Also cleared against K103140: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K261604Enobio Dx (Enobio Dx 8);Enobio Dx (Enobio Dx 20);Enobio Dx (Enobio Dx 32)Neuroelectrics Barcelona S.L.U.20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 6 companies; a new generation was cleared every 3.1 years on median.
  • 3 of the 14 ancestors have a recall of any class.
  • Of its descendants, K261604 (Neuroelectrics Barcelona S.L.U., 2026) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K103140.

How does its category compare?

All GWQ devices

GWQ Full-Montage Standard Electroencephalograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · GWQ

1in 2024

2007: 12008: 22010: 32011: 42012: 42013: 22014: 22015: 32016: 32017: 52018: 82020: 62022: 32023: 62024: 12026 (partial year): 2
2007high 8 (2018) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWQ

137in 2023

2010: 73 days median2011: 220 days median2012: 208 days median2015: 276 days median2016: 50 days median2017: 181 days median2018: 150 days median2020: 216 days median2022: 216 days median2023: 137 days median
2007high 276 (2015) · low 50 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWQ

1in 2020

2007: 52008: 22009: 12010: 12015: 22019: 22020: 12026 (partial year): 1
2007high 5 (2007) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWQ

13in 2025

2007: 112008: 82009: 72010: 122011: 62012: 92013: 42014: 72015: 132016: 282017: 172018: 152019: 162020: 302021: 202022: 162023: 202024: 172025: 13
2007high 30 (2020) · low 4 (2013)2025

MAUDE reports naming product code GWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—511
20082—28
20090—17
2010373112
2011422006
2012420809
20132—04
20142—07
20153276213
2016350028
20175181017
20188150015
20190—216
20206216130
20210—020
20223216016
20236137020
20241—017
20250—013
20262—1—

What is it indicated for?

ENOBIO is an EEG portable monitoring device of 8, 20, 32 channels intended for the use in clinical patient monitoring

for use in hospitals and other medical environments.

The Enobio is intended to acquire, store, transmit and display electrophysiological signals in wireless mode as an aid in

diagnostics. The system digitizes analogue EEG signals collected by a cap with electrodes, amplifies them, and uses WiFi

connectivity to transmit the EEG data to a dedicated host computer with the software.

This device is intended to be used by trained health-care personnel. It is restricted to sale by or on order of a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K162681: Enobio Wireless EEG.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162681

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026