510(k) Report

510(k) · Cleared

Cleared

Raycast High Precision Lung Board Solution

K162862510(k) TraditionalCleared Nov 9, 201628-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Orfit Industries NV · IYE Accelerator, Linear, Medical

Cleared on Nov 9, 2016 as substantially equivalent to K040773 (Bionix Development Corp., 2004) after a 28-day review. Its family tree reaches back 2 generations to 1990.

Decided
Nov 9, 2016
Review
28 days
Class
Class II
Product code
IYE
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K895697 (1990). 8 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2002: 1 other ancestor1997: 1 other ancestor1995: 2 other ancestors1994: 2 other ancestorsK895697 · Vac Fix (R) System · S&S Par Scientific · 1990K040773 · Pelvis Bellyboard Plus Patient Positioning System · Bionix Development Corp. · 2004199019952000200520102015
Other ancestors, by generation 2 generations back: 6 other ancestors K040773 · Pelvis Bellyboard Plus Patient Positioning System · Bionix Development Corp. · 2004K895697 · Vac Fix (R) System · S&S Par Scientific · 19900
  1. Root · 2 generations backK895697 Vac Fix (R) SystemS&S Par Scientific · 1990
  2. 1 generation backK040773 Pelvis Bellyboard Plus Patient Positioning SystemBionix Development Corp. · 2004
  3. This deviceK162862 Raycast High Precision Lung Board SolutionOrfit Industries NV · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K895697Vac Fix (R) SystemS&S Par Scientific1990—
−1K040773Pelvis Bellyboard Plus Patient Positioning SystemBionix Development Corp.2004—
0 (this device)K162862Raycast High Precision Lung Board SolutionOrfit Industries NV2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199520
199710
200210
FIG. 1 — Lineage of K162862, 1990–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYE device

  1. #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040773Pelvis Bellyboard Plus Patient Positioning System
Summary page 4
…: Radiology Product Code: IYE Device Class: Class II Regulation: 892.5050 Predicate Device Information K040773 Extended Butterfly Board, Bionix Development Corp., Intended Use/Indications for Use The Raycast High Precision Lung Board is a…
Bionix Development Corp.2004—

Also cleared against K040773: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 14.2 years on median.
  • 1 of the 8 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K040773.

How does its category compare?

All IYE devices

IYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · IYE

12in 2025

2007: 232008: 142009: 202010: 232011: 112012: 282013: 182014: 202015: 202016: 212017: 232018: 212019: 192020: 202021: 192022: 122023: 182024: 92025: 122026 (partial year): 14
2007high 28 (2012) · low 9 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYE

170in 2025

2007: 44 days median2008: 69 days median2009: 63 days median2010: 74 days median2011: 94 days median2012: 106 days median2013: 88 days median2014: 100 days median2015: 108 days median2016: 97 days median2017: 94 days median2018: 58 days median2019: 83 days median2020: 67 days median2021: 86 days median2022: 172 days median2023: 129 days median2024: 239 days median2025: 170 days median2026 (partial year): 120 days median
2007high 239 (2024) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYE

1in 2025

2007: 782008: 492009: 222010: 272011: 732012: 202013: 112014: 142015: 82016: 72017: 72018: 72019: 22020: 42021: 52022: 32023: 72024: 12025: 12026 (partial year): 4
2007high 78 (2007) · low 1 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYE

101in 2025

2007: 1552008: 1142009: 1742010: 2462011: 2802012: 1282013: 962014: 1242015: 1002016: 972017: 1252018: 852019: 912020: 742021: 682022: 662023: 1282024: 812025: 101
2007high 280 (2011) · low 66 (2022)2025

MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007234478155
2008146949114
2009206322174
2010237427246
2011119473280
20122810620128
201318881196
20142010014124
2015201088100
20162197797
201723947125
20182158785
20191983291
20202067474
20211986568
202212172366
2023181297128
20249239181
2025121701101
2026141204—

What is it indicated for?

The Raycast High Precision Lung Board Solution is a patient positioning device intended to be used for the positioning and re-positioning of patients undergoing or receiving a course of external beam radiation therapy for the treatment of cancer and other diseases. It is intended to be used by or under the direction of a licensed physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K162862: Raycast High Precision Lung Board Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162862

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026