510(k) Report

510(k) · Cleared

Cleared

dS Small Extremity 16CH 1.5T Coil

K162863510(k) TraditionalCleared Nov 7, 201625-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Invivo Therapeutics Corporation · MOS Coil, Magnetic Resonance, Specialty

Cleared on Nov 7, 2016 as substantially equivalent to K091902 (Invivo, 2009) after a 25-day review. Its family tree reaches back 2 generations to 1998. 2 later devices descend from it.

Decided
Nov 7, 2016
Review
25 days
Class
Class II
Product code
MOS
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K983109 (1998). 2 later devices descend from it, 1 citing it directly.

  1. Root · 2 generations backK983109 Model 545G-64 Pahased Array Musculoskeletal Flex Coil Package Model…Medical Advances, Inc. · 1998
  2. 1 generation backK091902 1.5T 8-Channel Small Extremity Coil, Model 800494, 3.0T 8-Channel…Invivo · 2009
  3. This deviceK162863 dS Small Extremity 16CH 1.5T CoilInvivo Therapeutics Corporation · 2016
  4. Descendant · cites it directly · 1 of its ownK213766 dS FootAnkle 16Ch Coils for 1.5T and 3.0T, dS HiRes HandWrist 16Ch…Invivo Corporation · 2021
  5. Descendant · 2 generations on · 0 of its ownK262294 dS FootAnkle 16Ch 1.5T;dS FootAnkle 16Ch 3.0T;dS HiRes Hand/Wrist…Philips Medical Systems Nederland B.V. · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K213766dS FootAnkle 16Ch Coils for 1.5T and 3.0T, dS HiRes HandWrist 16Ch Coils for 1.5T and…Invivo Corporation · 2021 · cites it directly1descendant
  • K262294dS FootAnkle 16Ch 1.5T;dS FootAnkle 16Ch 3.0T;dS HiRes Hand/Wrist 16Ch 1.5T;dS HiRes…Philips Medical Systems Nederland B.V. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K983109Model 545G-64 Pahased Array Musculoskeletal Flex Coil Package Model 543GE-64…Medical Advances, Inc.1998—
−1K0919021.5T 8-Channel Small Extremity Coil, Model 800494, 3.0T 8-Channel Small…Invivo2009—
0 (this device)K162863dS Small Extremity 16CH 1.5T CoilInvivo Therapeutics Corporation2016—
+1K213766dS FootAnkle 16Ch Coils for 1.5T and 3.0T, dS HiRes HandWrist 16Ch Coils for…Invivo Corporation2021—
+2K262294dS FootAnkle 16Ch 1.5T;dS FootAnkle 16Ch 3.0T;dS HiRes Hand/Wrist 16Ch 1.5T;dS…Philips Medical Systems Nederland B.V.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
202610
FIG. 1 — Lineage of K162863, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOS device

  1. #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K0919021.5T 8-Channel Small Extremity Coil, Model 800494, 3.0T 8-Channel Small Extremity Coil…
Summary page 7
…e 510(k) Submission Reference 1.5T and 3.0T-8Channel Small Extremity Coil K091902 Safety and Effectiveness: The proposed dS Small Extremity 16Ch 1.5T Coil labeling contain instructions for use and…
Invivo2009—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213766dS FootAnkle 16Ch Coils for 1.5T and 3.0T, dS HiRes HandWrist 16Ch Coils for 1.5T and…Invivo Corporation20211

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 10.9 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K213766 (Invivo Corporation, 2021) has gone furthest, with 1 descendant of its own.

How does its category compare?

All MOS devices

MOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · MOS

3in 2025

2007: 162008: 192009: 102010: 162011: 252012: 152013: 72014: 122015: 62016: 112017: 92018: 102019: 32020: 52021: 42022: 112023: 102024: 102025: 32026 (partial year): 10
2007high 25 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOS

59in 2025

2007: 19 days median2008: 33 days median2009: 43 days median2010: 78 days median2011: 57 days median2012: 49 days median2013: 87 days median2014: 60 days median2015: 58 days median2016: 42 days median2017: 63 days median2018: 30 days median2019: 178 days median2020: 51 days median2021: 41 days median2022: 79 days median2023: 59 days median2024: 39 days median2025: 59 days median2026 (partial year): 45 days median
2007high 178 (2019) · low 19 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOS

13in 2024

2008: 22010: 12012: 12015: 22019: 82020: 12024: 13
2007high 13 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MOS

2in 2025

2007: 42008: 22009: 52010: 132011: 72012: 122013: 102014: 42015: 52016: 72017: 92018: 72019: 82020: 22021: 32022: 52023: 42024: 82025: 2
2007high 13 (2010) · low 2 (2008)2025

MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007161904
2008193322
2009104305
20101678113
2011255707
20121549112
2013787010
2014126004
201565825
2016114207
201796309
2018103007
2019317888
202055112
202144103
2022117905
2023105904
20241039138
202535902
202610450—

What is it indicated for?

The dS Small Extremity 16Ch 1.5T Coil is to be used in conjunction with a Philips 1.5T Magnetic Resonance Scanner to produce diagnostic images of the extremities that can be interpreted by a trained physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K162863: dS Small Extremity 16CH 1.5T Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K162863

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026